> ## Documentation Index
> Fetch the complete documentation index at: https://doc.sensolus.com/llms.txt
> Use this file to discover all available pages before exploring further.

# TRACK 1105

> TRACK 1105

export const HeaderBadge = ({type, checkDms = false}) => {
  function addGroupBadge(h1Id) {
    const h1Element = document.getElementById(h1Id);
    if (!h1Element) {
      console.error(`Element with ID "${h1Id}" not found`);
      return;
    }
    if (h1Element.querySelector('.header-badge')) {
      console.warn('Header badge already exists on this element');
      return;
    }
    const badge = document.createElement('span');
    badge.className = 'header-badge';
    var badgeText;
    var badgeColor;
    switch (type) {
      case 'public':
        badgeText = 'Public';
        badgeColor = '#858585ff';
        break;
      case 'end-user':
        badgeText = 'End-User';
        badgeColor = '#0071a1';
        break;
      case 'multi-org':
        badgeText = 'Multi-Org';
        badgeColor = '#0071a1';
        break;
      case 'partner':
        badgeText = 'Partner';
        badgeColor = '#0071a1';
        break;
      case 'partner-pricing-eu':
        badgeText = 'Partner-EU';
        badgeColor = '#0071a1';
        break;
      case 'partner-pricing-us':
        badgeText = 'Partner-US';
        badgeColor = '#0071a1';
        break;
      case 'partner-pricing-world':
        badgeText = 'Partner-World';
        badgeColor = '#0071a1';
        break;
      case 'sensolus-internal':
        badgeText = 'Sensolus only';
        badgeColor = '#ffa858';
        break;
      default:
        badgeText = type;
        badgeColor = '#ffa858';
    }
    badge.textContent = badgeText;
    badge.style.cssText = `
        background-color: ${badgeColor};
        color: white;
        padding: 0.3em 0.8em 0.3em 0.8em;
        border-radius: 6px;
        font-size: 0.4em;
        margin-left: 20px;
        vertical-align: middle;
    `;
    h1Element.appendChild(badge);
  }
  function checkDocumentationServerAccess(type) {
    fetch('https://cloud.sensolus.com/documentation/user', {
      method: 'GET',
      headers: {
        'Accept': 'application/json'
      },
      credentials: 'include'
    }).then(response => {
      if (!response.ok) {
        console.error('Could not fetch documentation server user:', response);
      }
      return response.json();
    }).then(user => {
      const compatibleGroups = {
        "NORMAL": ["end-user", "public"],
        "PUBLIC": ["public"],
        "PARTNER": ["partner", "public", "end-user", "multi-org"],
        "MULTI_ORG": ["multi-org", "public", "end-user"],
        "SYSTEM": ["public", "end-user", "multi-org", "partner", "sensolus-internal"]
      };
      const allowedGroups = compatibleGroups[user.orgType] || [];
      const compatiblePriceListGroups = {
        "EU": ["partner-pricing-eu"],
        "US": ["partner-pricing-us"],
        "WORLD": ["partner-pricing-eu", "partner-pricing-us", "partner-pricing-world"]
      };
      allowedGroups.push(...compatiblePriceListGroups[user.orgType === "SYSTEM" ? "WORLD" : user.priceList] || []);
      if (!allowedGroups.includes(type)) {
        if (user.orgType === 'PUBLIC') {
          window.location.href = '/login?redirect=' + encodeURIComponent(window.location.pathname);
        } else {
          window.location.href = '/logout';
        }
      }
      addGroupBadge("page-title");
    }).catch(error => {
      console.error('Could not fetch documentation server user:', error);
      addGroupBadge("page-title");
    });
  }
  useEffect(() => {
    console.info("adding badge");
    addGroupBadge("page-title");
  });
  useEffect(() => {
    console.info("checking server access for type" + type);
    if (type && type !== 'public' && checkDms) {
      checkDocumentationServerAccess(type);
    }
  }, [type]);
  return <></>;
};

<HeaderBadge type={'public'} checkDms={false} />

<Frame>
  <img src="https://mintcdn.com/sensolus/W-UskwQvZFv0YXIw/docs/spec_sheets/trackers/images/TRACK-1105.png?fit=max&auto=format&n=W-UskwQvZFv0YXIw&q=85&s=f18e617bdfd9a23a2f31d70d10bfdd66" width="200" data-path="docs/spec_sheets/trackers/images/TRACK-1105.png" />
</Frame>

<AccordionGroup>
  <Accordion title="TRACK 1100, 1101, 1105, 1105 IF, 1215 drill hole template (pdf)" icon="file">
    **Description**: TRACK 1100, 1101, 1105, 1105 IF, 1215 drill hole template. Use this to drill holes at the correct distances when installing a tracker on an asset.<br />
    **Access level**: public<br />
    **Reference**: SDOC-498608282-64<br />
    **Download**:  [PDF](https://cloud.sensolus.com/documentation/dms/SDOC-498608282-64)

    <iframe src="https://cloud.sensolus.com/documentation/dms/SDOC-498608282-64?viewer=true" style={{width: '100%', height: '881px', border: 'none', margin: 0, padding: 0}} />

    <div style={{display: "none"}} data-pdf-text="true">
      115 mm
      Drilling hole patterns for
      TRACK 1000 1001 1040  1100
      Do not scale this drawing!
      Print on A4 paper
    </div>
  </Accordion>

  <Accordion title="TRACK 1105 (pdf)" icon="file">
    **Description**: <br />
    **Access level**: public<br />
    **Reference**: SDOC-498608282-1359<br />
    **Download**:  [PDF](https://cloud.sensolus.com/documentation/dms/SDOC-498608282-1359)

    <iframe src="https://cloud.sensolus.com/documentation/dms/SDOC-498608282-1359?viewer=true" style={{width: '100%', height: '881px', border: 'none', margin: 0, padding: 0}} />

    <div style={{display: "none"}} data-pdf-text="true">
      TRACK 1105
      GNSS/Wi-Fi/BLE - NB-IoT/LTE-M
      [www.sensolus.com](http://www.sensolus.com) | [info@sensolus.com](mailto:info@sensolus.com)
      The rugged low-power tracker with long battery life
      with NB-IoT and LTE-M connectivity and guaranteed
      data recovery. The tracker provides general
      localization, zone and high precision. The tracker
      comes with an onboard temperature sensor and shock
      detection. Compatible with multiple external
      environmental sensors. The tracker firmware can be
      upgraded over the air.
      GNSS
      Wi-Fi scanning
      Bluetooth geobeacon for zone precision
      Quuppa tested for high precision
      NB-IoT
      LTE-M
      Europe and North America
      Data recovery
      IP69K & IP68
      IK 09
      Flame retardant
      130×72×36 mm
      212g (7.6 oz)
      Connectivity
      NB-IoT and LTE-M
      •
      Energy efficient transceiver
      •
      Internal omnidirectional antenna
      •
      Bi-directional communication
      •
      NB-IoT and LTE-M bands: Europe/North America
      •
      Data recovery
      •
      OTA firmware upgrade (NB-IoT or LTE-M)
      Connectivity plan
      •
      TRACK 1105 comes with the Extended connectivity plan
      Bluetooth Low Energy (BLE)
      Bluetooth Low Energy 5.0
      Geolocalization
      GNSS
      Multi GNSS constellation chipset (GPS+GALILEO)
      BLE
      •
      Sensolus proximity beacon detection
      •
      Detectable by zone and high precision anchors
      Wi-Fi scanning
      •
      Wi-Fi based geolocalization
      •
      Wi-Fi 2.4 GHz

      TRACK 1105
      GNSS/Wi-Fi/BLE - NB-IoT/LTE-M
      [www.sensolus.com](http://www.sensolus.com) | [info@sensolus.com](mailto:info@sensolus.com)
      Sensing
      Internal
      •
      Activity monitoring
      •
      Orientation monitoring
      •
      Virtual tamper detection
      •
      Temperature monitoring
      •
      range: -20°C till 60°C (-4°F to 140°F)
      •
      typical accuracy: +/- 0.25°C (+/- 0.45°F)
      •
      worst case accuracy: +/- 1°C (+/- 1.8°F)
      •
      Configurable shock detection
      Environmental BLE sensors
      •
      Temperature, humidity
      •
      Fill level, contact, magnet
      •
      Other BLE sensors can be added
      Activation and mounting
      •
      Activation and mounting
      •
      Activation manual
      •
      Holes 7x9mm (⁹/₃₂ \&#42; ²³/₆₄ in) for screws or rivets. 115 mm
      (4¹⁷/₃₂ in) distance between the centers of the mounting
      holes.
      •
      Instructions for mounting the device are available in the
      Sensolus documentation center.
      Mechanics & Design
      Antennas
      All antennas are internal
      Water & dust resistance
      IP68 & IP69K
      Size
      130x72x36 mm
      (5⅛ x 2⁵³⁄₆₄ x 1²⁷⁄₆₄ in)
      Impact resistance
      IK09
      Weight
      212 gram (7.6 oz)
      Drop shock and vibration
      EN 60068
      Color
      White
      Operating temperature
      -20°C to 60°C
      (-4°F to 140°F)\&#42;
      The specifics regarding operational temperature are contingent upon the
      application, installation circumstances, and environmental factors such as
      sunlight exposure. For further information, please reach out to Sensolus.
      Battery life can be affected when devices function for extended periods at the
      extremes of this range.
      Casing
      •
      Shell: PBT + PC Cover: PBT GF30% + TPE
      •
      Flame retardant
      •
      UV-stabilized
      Battery
      Standard 3 cell
      •
      User replaceable battery pack (Li-SoCl₂) 10800 mAh
      •
      2.94 gram (0.1037oz) lithium

      TRACK 1105
      GNSS/Wi-Fi/BLE - NB-IoT/LTE-M
      [www.sensolus.com](http://www.sensolus.com) | [info@sensolus.com](mailto:info@sensolus.com)
      Certifications
      Regulatory
      •
      CE
      •
      FCC
      •
      IC
      Bluetooth 5.0
      Declaration ID D068598
      Environmental
      Drop shock in progress
      Electrical safety
      EN 62368-1
      User Interaction
      Device activation
      Magnetic activation
      LED feedback
      Green & red LED feedback on the device
      Synchronize remote settings
      •
      Instant: Magnet activation
      •
      Periodic: No user interaction needed
      Management Services
      Diagnostics
      •
      Battery lifetime prediction
      •
      Detailed energy consumption
      •
      Geolocation diagnostics
      •
      Installation
      •
      Communication quality
      Management
      •
      OTA firmware updates over NB-IoT,LTE-M and BLE
      •
      Remote configuration
      •
      Tracker usage profiles
      •
      External environmental sensors
      Application services
      •
      Localization
      •
      Journeys
      •
      Activity
      •
      Utilization
      •
      Connectable with environmental sensors
      •
      Temparture detection
      •
      Tilt detection
      •
      Shock detection

      TRACK 1105
      GNSS/Wi-Fi/BLE - NB-IoT/LTE-M
      [www.sensolus.com](http://www.sensolus.com) | [info@sensolus.com](mailto:info@sensolus.com)
      Firmware configuration
      Communication service
      •
      Data recovery strategy
      •
      Communication conditions
      Location service
      •
      Motion based,context based, periodic or scheduled
      •
      Configurable update rate and journey detection
      •
      Priority sequence (GNSS, Wi-Fi scanning , Bluetooth
      geobeacon)
      •
      GNSS fix parameters
      •
      Quuppa certified for high precision
      •
      Indoor detection algo
      •
      Wi-Fi scan strategy
      •
      BLE scan strategy
      General configuration
      •
      Rule engine configuration
      •
      Diagnostic levels
      •
      Boot methods
      •
      Accurate time synchronization
      Orientation service
      Orientation detection parameters
      Environmental sensing
      •
      Polling and aggregation strategy
      •
      Alerts
      •
      Edge processing parameters
      Activity service
      Activity detection parameters
      Tamper service
      Virtual tamper algo configuration
      Shock detection
      Shock algo detection parameters
      Security
      •
      Device unique encryption keys
      •
      End to end payload encryption Chacha 20
      •
      AES encrypted firmware
      •
      Firmware upgrade allows only signed firmware images
    </div>
  </Accordion>

  <Accordion title="Installation and activation manual TRACK 1105 (pdf)" icon="file">
    **Description**: <br />
    **Access level**: public<br />
    **Reference**: SDOC-498608282-1398<br />
    **Download**:  [PDF](https://cloud.sensolus.com/documentation/dms/SDOC-498608282-1398)

    <iframe src="https://cloud.sensolus.com/documentation/dms/SDOC-498608282-1398?viewer=true" style={{width: '100%', height: '881px', border: 'none', margin: 0, padding: 0}} />

    <div style={{display: "none"}} data-pdf-text="true">
      Installation and activation manual TRACK 1105
      [www.sensolus.com](http://www.sensolus.com) | [info@sensolus.com](mailto:info@sensolus.com)
      November 21, 2025 9:47 AM
      Mounting the tracker
      Guidelines how to mount the tracker can be found here.
      Tracker activation
      Activation of the trackers is preferably done with clear skies, and not inside (e.g. factory or warehouse).
      Trackers are not activated when delivered to your premises.
      Their subscription in the platform will start within six months of purchase.
      1
      Hold a magnet for
      about 5 seconds on
      top of the logo on the
      asset tracker.
      →
      2
      You will first see a red
      LED. Do not remove
      the magnet yet.
      →
      3
      When the green LED
      is blinking you can
      remove the magnet.
      Your tracker is ready
      for use.
      Activation troubleshooting
      Activating a tracker that communicates over the NB-IoT or LTE-M network can sometimes come with a delay. With a delay we
      mean that the online status doesn\&#39;t appear within 5 minutes after holding the magnet to the tracker. This is mostly due to
      conditions on the network operator site.
      If the activation wasn\&#39;t successful after 5 minutes the tracker will try again to activate again after waiting 24 hours.
      This long period of time is often an obstacle to start installing trackers to assets and makes the timing of the installation of the
      trackers cumbersome as it is important to only install trackers when they appeared as online on the platform.
      To overcome to 24 hours waiting time, you can do the following:
      If after 5 minutes of waiting and the status didn\&#39;t change yet to "online" hold the magnet again for 5 seconds on top of the
      tracker to enforce a new attempt for activation. Keep trying every 5 minutes until the Online status appears.
      Installation advice
      Avoid blocking the tracker\&#39;s view
      with metal or carbonfibre walls.
      They weaken or block the
      radiofrequency signals.
      Place the tracker as high as
      possible on the asset to ensure
      good network coverage.
      Make sure the mounting surface
      is flat and clean, for a strong and
      durable bond.
      Do not install the tracker on
      parts that receive frequent
      shocks or vibrations.

      Installation and activation manual TRACK 1105
      [www.sensolus.com](http://www.sensolus.com) | [info@sensolus.com](mailto:info@sensolus.com)
      November 21, 2025 9:47 AM
      Install the tracker vertically, with
      the logo facing up.
      If your asset is handled in a rough
      environment, you can place the
      tracker in a protected location,
      but never with metal or
      carbonfibre above the tracker.
      Make sure the tracker has a clear
      view on the sky.
      Avoid placing the tracker in a
      place that can collect water.
      If you can\&#39;t install vertically, do
      not mount the tracker upside
      down.
      It is advisable to place a thermal
      insulation material, such as wood
      or plastic, between the tracker
      and the metal asset if the latter is
      subjected to prolonged exposure
      to sunlight.
      Troubleshooting

      1. Put the magnet on the tracker for less than 5 seconds
      2. The possible LED feedback options are:
         Red LED: Tracker is not activated
         Green LED: Tracker is activated
         and working properly
         No LED: tracker is not
         functioning (probably dead
         battery -> contact support)
         Red LED is blinking: Tracker is
         busy

      Installation and activation manual TRACK 1105
      [www.sensolus.com](http://www.sensolus.com) | [info@sensolus.com](mailto:info@sensolus.com)
      November 21, 2025 9:47 AM
      Force new configuration download on the tracker
      1
      Hold a magnet for
      about 5 seconds on
      top of the logo on the
      asset tracker. You will
      see a green LED.
      →
      2
      You will see a red and
      green LED. Now
      remove the magnet.
      →
      3
      Green LED is blinking
      for minimum 30
      seconds. Your tracker
      is checking for new
      configurations.
      →
      You see a red LED:
      No new
      configuration
      received.
      You see a green
      LED: New
      configuration setting
      received.

      Installation and activation manual TRACK 1105
      [www.sensolus.com](http://www.sensolus.com) | [info@sensolus.com](mailto:info@sensolus.com)
      November 21, 2025 9:47 AM
      Regulatory Information
      Federal Communication Commission Interference Statement
      This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

      1. This device may not cause harmful interference, and
      2. This device must accept any interference received, including interference that may cause undesired operation.
         This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
         provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and,
         if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that
         interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined
         by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
         •
         Reorient or relocate the receiving antenna.
         •
         Increase the separation between the equipment and receiver.
         •
         Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
         •
         Consult the dealer or an experienced radio/TV technician for help.
         FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user\&#39;s authority to operate this
         equipment.
         This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
         Radiation Exposure Statement:
         This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
         This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
         This equipment is not suitable for use in locations where children are likely to be present.
         Industry Canada Statement
         This device complies with ISED\&#39;s licence-exempt RSSs.
         Operation is subject to the following two conditions:
         This device may not cause harmful interference, and
         This device must accept any interference received, including interference that may cause undesired operation.
         Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter
         by Industry Canada.
         To reduce potential radio interference to other users, the antenna type and its gain should be chosen so that the equivalent isotropically radiated power (e.i.r.p.) is
         not more than that necessary for successful communication.
         RF Exposure Requirements:
         This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment.
         This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
         Le présent appareil est conforme aux CNR d\&#39; ISED applicables aux appareils radio exempts de licence.
         L\&#39;exploitation est autorisée aux deux conditions suivantes:
      3. le dispositif ne doit pas produire de brouillage préjudiciable, et
      4. ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable.
         Conformément à la réglementation d\&#39;Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d\&#39;un type et d\&#39;un gain maximal (ou inférieur)
         approuvé pour l\&#39;émetteur par Industrie Canada.
         Dans le but de réduire les risques de brouillage radio électrique à l\&#39;intention des autres utilisateurs, il faut choisir le type d\&#39;antenne et son gain de sorte que la
         puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l\&#39;intensité nécessaire à l\&#39;établissement d\&#39;une communication satisfaisante.
         Déclaration d\&#39;exposition aux radiations:
         Cet équipement est conforme aux limites d\&#39;exposition aux rayonnements du Canada établies pour un environnement non contrôlé.
         Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.

      Installation and activation manual TRACK 1105
      [www.sensolus.com](http://www.sensolus.com) | [info@sensolus.com](mailto:info@sensolus.com)
      November 21, 2025 9:47 AM
      Safety advice – device subjected to strong mechanical impact
      Risk of delayed battery failure and chemical hazard
      If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the
      internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed
      overheating, leakage, or failure.
      If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken:
      \#
      Action
      Details
      1
      Do not touch the device
      Do not move, lift, open, shake, or inspect the
      device immediately after the impact. Internal
      damage may cause delayed reactions.
      2
      Keep a minimum safety distance
      Maintain a clear distance of at least 5 meters
      from the device. Keep all personnel away
      during this period.
      3
      Wait at least 10 minutes
      The device must remain untouched and
      undisturbed for a minimum of 10 minutes
      following the impact. This waiting time
      allows potential delayed thermal or chemical
      reactions to become evident.
      4
      Observe from a safe distance
      Watch for warning signs: smoke, vapor, or
      unusual odor; heat generation; fluid leakage;
      hissing, cracking, or popping noises.
      5
      After the waiting period
      If any abnormal condition is observed,
      isolate the area immediately and notify
      responsible safety or supervisory personnel.
      The device must be quarantined and
      handled according to battery safety and
      disposal procedures. The device must not be
      used.
      A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe.
      Failure to follow this safety advice may result in serious injury, fire, or chemical exposure.
    </div>
  </Accordion>
</AccordionGroup>

For installation instructions, see [Installation instructions](/docs/spec_sheets/installation_instructions).
