TRACK 1010 1110 drill hole template (pdf)
TRACK 1010 1110 drill hole template (pdf)
Description: TRACK 1010 and 1110 drill hole template. Use this to drill holes at the correct distances when installing a tracker on an asset.
Access level: public
Reference: SDOC-498608282-77
Download: PDF
Access level: public
Reference: SDOC-498608282-77
Download: PDF
90 mm
Drilling hole patterns for
TRACK 1010 and TRACK 1110
Do not scale this drawing!
Print on A4 paper
TRACK 1110 (pdf)
TRACK 1110 (pdf)
Description:
Access level: public
Reference: SDOC-498608282-1333
Download: PDF
Access level: public
Reference: SDOC-498608282-1333
Download: PDF
sensolus
TRACK 1110
GNSS/Wi-Fi/BLE - NB-IoT
www.sensolus.com | info@sensolus.com
The small low-power tracker with long
battery life. Indoor and outdoor
localization, zone and high precision.
Compatible with multiple external
environmental sensors.
GNSS
Wi-Fi scanning
Bluetooth geobeacon for zone precision
NB-IoT
Europe
Data recovery
IP68
Flame retardant
105×54×21.5 mm
95g (7.6 oz)
Connectivity
NB-IoT
•
Energy efficient transceiver
•
Internal omnidirectional antenna
•
Bi-directional communication
•
NB-IoT bands: Europe
•
Data recovery
•
OTA firmware upgrade (NB-IoT)
Bluetooth Low Energy (BLE)
•
BLE 2.4 Ghz
•
Bluetooth Low Energy 5.0
Geolocalization
GNSS
•
Multi GNSS constellation chipset (GPS+GALILEO)
•
Patch antenna for optimum performance
BLE
•
Sensolus proximity beacon detection
•
Detectable by zone and high precision anchors
Wi-Fi scanning
•
Wi-Fi based geolocalization
•
Wi-Fi 2.4 GHz
Sensing
Internal
•
Activity monitoring
•
Orientation monitoring
•
Virtual tamper detection
Environmental BLE sensors
•
Temperature, humidity
•
Fill level, contact, magnet
•
Other BLE sensors can be addedsensolus
TRACK 1110
GNSS/Wi-Fi/BLE - NB-IoT
www.sensolus.com | info@sensolus.com
Activation and mounting
Activation
Mounting
•
Activation and mounting
•
Activation manual
•
Holes 6x8 mm. 90 mm distance between the
centers of the mounting holes.
•
Instructions for mounting the device are available
here.
Mechanics & Design
Antennas
All antennas are internal
Water & dust resistance
IP68
Size
105x54x21.5 mm (LWH)
Weight
95 gram
Color
Translucent black
Operating temperature
-20°C to 60°C*
The specifics regarding operational temperature are contingent upon
the application, installation circumstances, and environmental factors
such as sunlight exposure. For further information, please reach out
to Sensolus. Battery life can be affected when devices function for
extended periods at the extremes of this range.
Casing
•
Polycarbonate (lexan943A)
•
Flame retardant
•
UV-stabilized
Battery
•
3 to 8 years battery life depending on operating
mode
•
Non replaceable battery pack5200 mAh 3.0
V(Li-MnO₂)
Certifications
Regulatory
CE
Bluetooth 5.0
Declaration ID D068598
Electrical safety
EN-60905-1
User Interaction
Device activation
Magnetic activation
LED feedback
Green & red LED feedback on the device
Synchronize remote settings
•
Instant: Magnet activation
•
Periodic: No user interaction neededsensolus
TRACK 1110
GNSS/Wi-Fi/BLE - NB-IoT
www.sensolus.com | info@sensolus.com
Management Services
Diagnostics
•
Battery lifetime prediction
•
Detailed energy consumption
•
Geolocation diagnostics
•
Installation
•
Communication quality
Management
•
OTA firmware updates over NB-IoT and BLE
•
Remote configuration
•
Tracker usage profiles
•
External environmental sensors
Application services
•
Localization
•
Journeys
•
Activity
•
Utilization
•
Connectable with environmental sensors
•
Tilt detection
Firmware configuration
Communication service
•
Data recovery strategy
•
Communication conditions
Location service
•
Motion based,context based, periodic or scheduled
•
Configurable update rate and journey detection
•
Priority sequence (GNSS, Wi-Fi scanning , Bluetooth
geobeacon)
•
GNSS fix parameters
•
Indoor detection algo
•
Wi-Fi scan strategy
•
BLE scan strategy
General configuration
•
Rule engine configuration
•
Diagnostic levels
•
Boot methods
•
Accurate time synchronization
Orientation service
Orientation detection parameters
Environmental sensing
•
Polling and aggregation strategy
•
Alerts
•
Edge processing parameters
Activity service
Activity detection parameters
Tamper service
Virtual tamper algo configuration
Security
Encryrption
•
Device unique encryption keys
•
End to end payload encryption Chacha 20
•
AES encrypted firmware
•
Firmware upgrade allows only signed firmware
images
Installation and activation manual TRACK 1110 (pdf)
Installation and activation manual TRACK 1110 (pdf)
Description:
Access level: public
Reference: SDOC-498608282-1399
Download: PDF
Access level: public
Reference: SDOC-498608282-1399
Download: PDF
Installation and activation manual TRACK 1110
www.sensolus.com | info@sensolus.com
November 21, 2025 9:47 AM
Mounting the tracker
Guidelines how to mount the tracker can be found here.
Tracker activation
Activation of the trackers is preferably done with clear skies, and not inside (e.g. factory or warehouse).
Trackers are not activated when delivered to your premises.
Their subscription in the platform will start within six months of purchase.
1
Hold a magnet for
about 5 seconds on
top of the logo on
the asset tracker.
→
2
You will first see a
red LED. Do not
remove the
magnet yet.
→
3
When the green
LED is blinking you
can remove the
magnet. Your
tracker is ready for
use.
Activation troubleshooting
Activating a tracker that communicates over the NB-IoT or LTE-M network can sometimes come with a delay.
With a delay we mean that the online status doesn't appear within 5 minutes after holding the magnet to the
tracker. This is mostly due to conditions on the network operator site.
If the activation wasn't successful after 5 minutes the tracker will try again to activate again after waiting 24
hours.
This long period of time is often an obstacle to start installing trackers to assets and makes the timing of the
installation of the trackers cumbersome as it is important to only install trackers when they appeared as
online on the platform.
To overcome to 24 hours waiting time, you can do the following:
If after 5 minutes of waiting and the status didn't change yet to “online” hold the magnet again for 5 seconds
on top of the tracker to enforce a new attempt for activation. Keep trying every 5 minutes until the Online
status appears.
Installation adviceInstallation and activation manual TRACK 1110
www.sensolus.com | info@sensolus.com
November 21, 2025 9:47 AM
Avoid blocking the tracker's
view with metal or
carbonfibre walls. They
weaken or block the
radiofrequency signals.
Place the tracker as high as
possible on the asset to
ensure good network
coverage.
Make sure the mounting
surface is flat and clean, for
a strong and durable bond.
Do not install the tracker on
parts that receive frequent
shocks or vibrations.
Install the tracker vertically,
with the logo facing up.
If your asset is handled in a
rough environment, you can
place the tracker in a
protected location, but never
with metal or carbonfibre
above the tracker.
Make sure the tracker has a
clear view on the sky.
Avoid placing the tracker in
a place that can collect
water.
If you can't install vertically,
do not mount the tracker
upside down.
Do not install the tracker on
the car dashboard.
Troubleshooting
- Put the magnet on the tracker for less than 5 seconds
- The possible LED feedback options are: Red LED: Tracker is not activated Green LED: Tracker is activated and working properly No LED: tracker is not functioning (probably dead battery -> contact support) Red LED is blinking: Tracker is busy Force new configuration download on the tracker
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This equipment is not suitable for use in locations where children are likely to be present. Industry Canada Statement This device complies with ISED's licence-exempt RSSs. Operation is subject to the following two conditions: This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be chosen so that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. RF Exposure Requirements: This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Le présent appareil est conforme aux CNR d' ISED applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes:
- le dispositif ne doit pas produire de brouillage préjudiciable, et
- ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radio électrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. Déclaration d'exposition aux radiations: Cet équipement est conforme aux limites d'exposition aux rayonnements du Canada établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.