# Source: https://doc.sensolus.com/index # Sensolus Documentation Search docs, APIs, and more... ## Quick Links > **[Spec sheets and manuals](/docs/spec_sheets/hardware_overview)** > > Spec sheets, installation manuals for trackers, sensors and other devices. > **[Platform status](https://status.sensolus.com)** > > Live status and uptime history of the Sensolus cloud platform. Tracker data is not lost during maintenance. # ADPT 8500 EU Source: https://doc.sensolus.com/docs/spec_sheets/accessories/adpt_8500_eu ADPT 8500 Power adapter EU for ZA3510, ZA3515 ![](https://mintcdn.com/sensolus/HqxTxygV4HahsQQu/docs/spec_sheets/accessories/images/ADPT_8500_EU.png?fit=max\&auto=format\&n=HqxTxygV4HahsQQu\&q=85\&s=b315a18a3285fe44e8aae2234da2ae9b) Power adaptor Europe: October 24, 2025 11:06 AM [www.sensolus.com](http://www.sensolus.com) | [info@sensolus.com](mailto:info@sensolus.com) Net power adaptor EU version ADPT 8500 EU 100 - 240 V 50/60 Hz Power input Voltage Frequency Power adapter featuring a power plug designed for use in mainland Europe, complete with a 2-meter long cable. IP 67 connector to ZA 3510 Europe Certifications 0,18 A Current CE Europe Mechanics & design Size 55.1 x 24.1 x 35.5 mm Color White wall-mount, 2 pin, EU Input plug 0°C to 50°C Operating temperature 0,1 W No load power consumption Yes RoHS Cable · UL 2464, 24 AWG · 2 meter long Plug 4 pins with screwable M5 connector # ADPT 8501 UK Source: https://doc.sensolus.com/docs/spec_sheets/accessories/adpt_8501_uk ADPT 8501 Power adapter UK for ZA3510, ZA3515 ![](https://mintcdn.com/sensolus/HqxTxygV4HahsQQu/docs/spec_sheets/accessories/images/ADPT_8501_UK.png?fit=max\&auto=format\&n=HqxTxygV4HahsQQu\&q=85\&s=0bc431c20a8a354de7b28219d8157450) Power adapter UK: October 24, 2025 11:06 AM [www.sensolus.com](http://www.sensolus.com) | [info@sensolus.com](mailto:info@sensolus.com) Net power adaptor EU version ADPT 8501 UK 100 - 240 V 50/60 Hz Power input Voltage Frequency Power adaptor featuring a power plug designed for use in UK, complete with a 2-meter long cable. IP 67 connector to ZA 3510 UK Certifications 0,18 A Current CE Europe Mechanics & design Size 55.10 x 49.50 x 42.49 mm Color White wall-mount, UK Input plug 0°C to 50°C Operating temperature 0,1 W No load power consumption Yes RoHS Cable · UL 2464, 24 AWG · 2 meter long Plug 4 pins with screwable M5 connector # ADPT 8502 USA Source: https://doc.sensolus.com/docs/spec_sheets/accessories/adpt_8502_usa ADPT 8502 Power adapter USA for ZA3510, ZA3515 ![](https://mintcdn.com/sensolus/HqxTxygV4HahsQQu/docs/spec_sheets/accessories/images/ADPT_8502_USA.png?fit=max\&auto=format\&n=HqxTxygV4HahsQQu\&q=85\&s=337da0415b3b144becf887a9c1877307) Power adaptor USA: October 24, 2025 11:06 AM [www.sensolus.com](http://www.sensolus.com) | [info@sensolus.com](mailto:info@sensolus.com) 100 - 240 V 50/60 Hz Power input Voltage Frequency Power adapter featuring a power plug designed for use in the USA, complete with a 2-meter long cable. IP 67 connector to ZA 3510 USA Certifications 0,18 A Current FCC part 15: Class B for radiated and conducted emissions USA Mechanics & design Size 55.1 x 24.1 x 35.5 mm Color White wall-mount, 2 pin, US Input plug 0°C to 50°C Operating temperature 0,1 W No load power consumption Net power adaptor USA version ADPT 8502 USA Yes RoHS Cable · UL 2464, 24 AWG · 2 meter long Plug 4 pins with screwable M5 connector # Battery packs Source: https://doc.sensolus.com/docs/spec_sheets/accessories/battery_packs Use this page to identify the specific battery pack needed to replace the internal battery of a tracking device. ## Battery replacements In the table below you find which battery pack you need to order for replacement. | Device | Replacement battery pack | | - | - | | SNT2 | [BAT 8202](/docs/spec_sheets/accessories/battery_packs#bat-8202) | | SNT3 ULTRA/TRACK 1000/TRACK 1001 | [BAT 8201](/docs/spec_sheets/accessories/battery_packs#bat-8201) | | TRACK 1100/TRACK 1140/TRACK 1000 MK2 | [BAT 8205](/docs/spec_sheets/accessories/battery_packs#bat-8205) | | TRACK 1101/TRACK 1141 | [BAT 8206](/docs/spec_sheets/accessories/battery_packs#bat-8206) | | TRACK 1210 | [BAT 8207](/docs/spec_sheets/accessories/battery_packs#bat-8207) | | ZA 3510 | [BAT 8207](/docs/spec_sheets/accessories/battery_packs#bat-8207) | | ZA 3505 | [BAT 8205](/docs/spec_sheets/accessories/battery_packs#bat-8205) | | TRACK 1105/TRACK 1215/ZA 3515 | [BAT 8209](/docs/spec_sheets/accessories/battery_packs#bat-8209) | | TRACK 1105 IF | [BAT 8208](/docs/spec_sheets/accessories/battery_packs#bat-8208) | | TRACK 1115/TRACK 1115 WL | [BAT 8210](/docs/spec_sheets/accessories/battery_packs#bat-8210) | ## Battery pack overview ### BAT 8210 | | | | - | - | | Picture | ![](https://mintcdn.com/sensolus/g3bfYlGADcjuA_wC/docs/spec_sheets/accessories/images/BAT_8210.png?fit=max\&auto=format\&n=g3bfYlGADcjuA_wC\&q=85\&s=d583e443beefdd0949402c6a7fa510f9) | | Voltage | 3.0 V | | Capacity | 4600 mAh | | Number of cells | 1 | | Lithium content >2gram | Yes | | Cell size/type | CP954442 (pouch cell) | | Battery PCB connector | short white ![](https://mintcdn.com/sensolus/YIEdQsLzKQopMtjR/docs/spec_sheets/accessories/images/connector_white.png?fit=max\&auto=format\&n=YIEdQsLzKQopMtjR\&q=85\&s=946d2577acff857dd89d1f48280f48f6) | ### BAT 8209 | | | | - | - | | Picture | ![](https://mintcdn.com/sensolus/L5xy1mnuzPcAjEWR/docs/spec_sheets/accessories/images/BAT_8209.png?fit=max\&auto=format\&n=L5xy1mnuzPcAjEWR\&q=85\&s=db05d732a427f440b116e4c165625c02) | | Voltage | 3.6 V | | Capacity | 10800 mAh | | Number of cells | 3 | | Lithium content >2gram | Yes | | Cell size/type | ER17505-3 + UPC1520 | | Battery PCB connector | short white ![](https://mintcdn.com/sensolus/YIEdQsLzKQopMtjR/docs/spec_sheets/accessories/images/connector_white.png?fit=max\&auto=format\&n=YIEdQsLzKQopMtjR\&q=85\&s=946d2577acff857dd89d1f48280f48f6) | ### BAT 8208 | | | | - | - | | Picture | ![](https://mintcdn.com/sensolus/L5xy1mnuzPcAjEWR/docs/spec_sheets/accessories/images/BAT_8208.png?fit=max\&auto=format\&n=L5xy1mnuzPcAjEWR\&q=85\&s=724b5847f11450fb91d5a07ae568f259) | | Voltage | 3.6 V | | Capacity | 5200 mAh | | Number of cells | 2 | | Lithium content >2gram | Yes | | Cell size/type | ER14505 | | Battery PCB connector | short white ![](https://mintcdn.com/sensolus/YIEdQsLzKQopMtjR/docs/spec_sheets/accessories/images/connector_white.png?fit=max\&auto=format\&n=YIEdQsLzKQopMtjR\&q=85\&s=946d2577acff857dd89d1f48280f48f6) | ### BAT 8207 | | | | - | - | | Picture | ![](https://mintcdn.com/sensolus/YIEdQsLzKQopMtjR/docs/spec_sheets/accessories/images/BAT_8207.png?fit=max\&auto=format\&n=YIEdQsLzKQopMtjR\&q=85\&s=39ca6c0260b8a4b5999231b7d394a0fd) | | Voltage | 3.6 V | | Capacity | 12000 mAh | | Number of cells | 3 | | Lithium content >2gram | Yes | | Cell size/type | ER18505 HCB | | Battery PCB connector | short white ![](https://mintcdn.com/sensolus/YIEdQsLzKQopMtjR/docs/spec_sheets/accessories/images/connector_white.png?fit=max\&auto=format\&n=YIEdQsLzKQopMtjR\&q=85\&s=946d2577acff857dd89d1f48280f48f6) | ### BAT 8206 | | | | - | - | | Picture | ![](https://mintcdn.com/sensolus/YIEdQsLzKQopMtjR/docs/spec_sheets/accessories/images/BAT_8206.png?fit=max\&auto=format\&n=YIEdQsLzKQopMtjR\&q=85\&s=d1de402ea2003a46d7199b1f5dc6df91) | | Voltage | 3.6 V | | Capacity | 10500 mAh | | Number of cells | 3 | | Lithium content >2gram | Yes | | Cell size/type | ER18505M HCB | | Battery PCB connector | short white ![](https://mintcdn.com/sensolus/YIEdQsLzKQopMtjR/docs/spec_sheets/accessories/images/connector_white.png?fit=max\&auto=format\&n=YIEdQsLzKQopMtjR\&q=85\&s=946d2577acff857dd89d1f48280f48f6) | ### BAT 8205 | | | | - | - | | Picture | ![](https://mintcdn.com/sensolus/YIEdQsLzKQopMtjR/docs/spec_sheets/accessories/images/devices_BAT_8205.png?fit=max\&auto=format\&n=YIEdQsLzKQopMtjR\&q=85\&s=b8d445be75886691539fb143f7b6cfcf) | | Voltage | 3.6 V | | Capacity | 8400 mAh | | Number of cells | 3 | | Lithium content >2gram | Yes | | Cell size/type | ER17505M | | Battery PCB connector | short white ![](https://mintcdn.com/sensolus/YIEdQsLzKQopMtjR/docs/spec_sheets/accessories/images/connector_white.png?fit=max\&auto=format\&n=YIEdQsLzKQopMtjR\&q=85\&s=946d2577acff857dd89d1f48280f48f6) | ### BAT 8204 | | | | - | - | | Picture | ![](https://mintcdn.com/sensolus/YIEdQsLzKQopMtjR/docs/spec_sheets/accessories/images/devices_BAT_8204.png?fit=max\&auto=format\&n=YIEdQsLzKQopMtjR\&q=85\&s=ab3d30d5f17535da692557f824797da4) | | Voltage | 3.6 V | | Capacity | 5600 mAh | | Number of cells | 2 | | Lithium content >2gram | No | | Cell size/type | ER17505M | | Battery PCB connector | short white ![](https://mintcdn.com/sensolus/YIEdQsLzKQopMtjR/docs/spec_sheets/accessories/images/connector_white.png?fit=max\&auto=format\&n=YIEdQsLzKQopMtjR\&q=85\&s=946d2577acff857dd89d1f48280f48f6) | ### BAT 8203 | | | | - | - | | Picture | ![](https://mintcdn.com/sensolus/YIEdQsLzKQopMtjR/docs/spec_sheets/accessories/images/devices_BAT_8203.png?fit=max\&auto=format\&n=YIEdQsLzKQopMtjR\&q=85\&s=86d01cd0e3f75bc979ed650f74a337fd) | | Voltage | 3.6 V | | Capacity | 10500 mAh | | Number of cells | 3 | | Lithium content >2gram | Yes | | Cell size/type | ER17505 | | Battery PCB connector | short white ![](https://mintcdn.com/sensolus/YIEdQsLzKQopMtjR/docs/spec_sheets/accessories/images/connector_white.png?fit=max\&auto=format\&n=YIEdQsLzKQopMtjR\&q=85\&s=946d2577acff857dd89d1f48280f48f6) | ### BAT 8202 | | | | - | - | | Picture | N/A | | Voltage | 3.6 V | | Capacity | N/A | | Number of cells | 2 | | Lithium content >2gram | No | | Cell size/type | ER17505-M | | Suitable for: | TRACK 1000 in-flight | ### BAT 8201 | | | | - | - | | Picture | ![](https://mintcdn.com/sensolus/YIEdQsLzKQopMtjR/docs/spec_sheets/accessories/images/devices_BAT_8201.png?fit=max\&auto=format\&n=YIEdQsLzKQopMtjR\&q=85\&s=2a3836b6381c396df9442b1d2ceb0ebc) | | Voltage | 3.6 V | | Capacity | 8400 mAh | | Number of cells | 3 | | Lithium content >2gram | Yes | | Cell size/type | ER17505-M | | Battery PCB connector | long red ![](https://mintcdn.com/sensolus/YIEdQsLzKQopMtjR/docs/spec_sheets/accessories/images/connector_red.png?fit=max\&auto=format\&n=YIEdQsLzKQopMtjR\&q=85\&s=43be54de7f62d0c1968b79358fd1403e) | ### BAT 8200 | | | | - | - | | Picture | ![](https://mintcdn.com/sensolus/YIEdQsLzKQopMtjR/docs/spec_sheets/accessories/images/devices_BAT_8200.png?fit=max\&auto=format\&n=YIEdQsLzKQopMtjR\&q=85\&s=0f0e1359c7f877bf4d59b45ae9ccfe24) | | Voltage | 3.6 V | | Capacity | 2600 mAh | | Number of cells | 1 (3 per tracker) | | Lithium content >2gram | No | | Cell size/type | LS14500 | | Battery PCB connector | none | Battery change manual for trackers: Order these battery packs as replacements. See the battery packs overview to find the correct battery pack for your device. Battery replacement should only be performed by trained personnel. Dispose of old batteries according to local regulations. Battery replacement procedure Indicate battery replaced in platform After replacing the battery in the tracker, indicate this in the platform to reset the battery information. Go to the tracker details page in the general section. You can search for the tracker or find it in the asset list or asset map. Click on the settings button on the far right. Navigate to the Battery tab. Click Replace battery and confirm the action. This will reset all battery information. Battery replacements In the table below you find which battery pack you need to order for replacement. Device Replacement battery pack --- --- SNT2 BAT 8202 SNT3 ULTRA/TRACK 1000/TRACK 1001 BAT 8201 TRACK 1100/TRACK 1140/TRACK 1000 MK2 BAT 8205 TRACK 1101/TRACK 1141 BAT 8206 TRACK 1210 BAT 8207 ZA 3510 BAT 8207 ZA 3505 BAT 8205 TRACK 1105/TRACK 1215/ZA 3515 BAT 8209 sensolus-internal Step 1 - Unscrew \*\*Step 1:\*\* Make sure that the serial number and logo are facing the right way up. Then turn the tracker face down. Unscrew the 6 screws. Tip: If using a power drill, use power setting 7, on low. Step 2 - Remove back plate \*\*Step 2:\*\* Remove the back plate and the 6 screws. Step 3 - Remove module \*\*Step 3:\*\* Take the module (battery pack + battery holder + PCB) out of the casing. You might need to tilt the casing a bit. Step 4 - Turn module \*\*Step 4:\*\* Turn around the module (battery pack + battery holder + PCB) so the PCB is on top. Step 5 - Move battery \*\*Step 5:\*\* Lift the module and move the battery pack from the insert to the side. Step 6 - Align battery \*\*Step 6:\*\* Align the battery pack next to the PCB and insert. Step 7 - Disconnect \*\*Step 7:\*\* Disconnect the battery pack from the PCB. Be careful when disconnecting the battery pack. Step 8 - Connect new battery \*\*Step 8:\*\* Connect the new battery pack to the PCB. A green LED will flash for some seconds. Step 9 - Move back \*\*Step 9:\*\* Move the battery pack back under the insert and PCB and flip the module. Step 10 - Align \*\*Step 10:\*\* Align the battery pack onto the insert. Step 11 - Place module \*\*Step 11:\*\* Place the module in the tracker. Use the alignment marks on the casing. Do not use force. There is only one way to put the module back in the tracker. Step 12 - Close \*\*Step 12:\*\* Close the tracker carefully. Your tracker is ready to use again. Battery change manual for trackers Navigate to tracker details Open settings Go to battery tab Replace battery # CAB 8600 Source: https://doc.sensolus.com/docs/spec_sheets/accessories/cab_8600 CAB 8600 6 meter power extension cable for TRACK 1210 and TRACK 1215 CAB 8600: Documentation CAB 8600 6 m power extension cable The 6-meter power cable is designed for use with TRACK 1210 and TRACK 1215. It has 4 pins and is securely attached to the tracker with an M5 screw connector. The cable does not come with connectors for the power source: connectors can be soldered to the cable ends. External power supply IP67 when connected CAB 8600 6 m cable length Compatibility Connected devices TRACK 1210 TRACK 1215 Connector to tracker M5 screw General specification Cable length 6 m Connections 4 pins Cable terminations Connectors to the power source can be soldered to the cable ends IP rating IP67 when connected Temperature range -40°C - 85°C Electrical specifications Rated voltage 60V AC/DC Rated current 1A Contact resistance ≤5 mΩ Insulation resistance ≥100 MΩ Mating cycles > 100 Certifications RoHS Yes SDOC-498608282-1044 6 meter power extension cable for TRACK 1215 / TRACK 1210 # MNT MAG 8110 Source: https://doc.sensolus.com/docs/spec_sheets/accessories/mnt_mag_8110 MNT MAG 8110 Magnet mounting kit MNT MAG 8110 Magnet mounting kit: The MNT MAG 8110 is a magnet mounting kit designed for TRACK 1000 and TRACK 1100 trackers. This kit provides a secure magnetic mounting solution for metal surfaces. Compatible devices The MNT MAG 8110 is compatible with the following tracker models: - TRACK 1000 - TRACK 1100 Kit contents The kit includes: - 2x M6 x 16 bolts - 2x magnets with internal thread - 2x washers Installation steps Step 1: Place the tracker on the magnets Place the tracker on top of the magnets. Make sure the metal protection on the magnets is facing up. Step 2: Line the washers Line the washers on top of the tracker\'s mounting holes. Step 3: Tighten the screws Tighten the screws on the magnets to secure the tracker in place. After installation, verify that the tracker is securely mounted and the magnets are firmly attached to the metal surface. Installation checklist Before completing the installation, verify the following: - \[ \] All kit components are present (2 bolts, 2 magnets, 2 washers) - \[ \] Metal protection on magnets is facing up - \[ \] Washers are properly positioned on mounting holes - \[ \] Screws are tightened securely - \[ \] Tracker is firmly mounted and stable - \[ \] Magnets are securely attached to the metal surface sensolus-internal 600px 400px 400px 400px MNT MAG 8110 Magnet mounting kit MNT MAG 8110 kit contents Place tracker on magnets Line washers on mounting holes Tighten screws # Installation advice for cooler trucks Source: https://doc.sensolus.com/docs/spec_sheets/asset_specific/cooler_trucks Installation advice for cooler trucks Optimal installation of a tracker on an asset is very important for the optimal working of the tracking solution. Good installation prolongs the battery lifetime of the tracker, good installation transmits information from the tracker faster to the Sensolus platform, good installation gives more accurate location information,... Installation advice for cooling trucks: Tracker installation - Do not install the tracker on the inside of the truck. Temperature sensor installation Temperature sensors monitor the internal conditions of the refrigerated trailer. - Temperature sensors inside in the middle of the trailer on any place. Install only one sensor. - Keep out of range of doors and moving parts. - Do not install the sensors in the pathway of loading and unloading the goods. Please keep in mind to use enough glue spread across the entire back surface. Install the sensor where you most likely will experience traffic in the back. If a sensor falls/knocks off it is possible they will remove it from the trailer while cleaning it, and we will not be able to find it back. Use glue that is suited for low temperatures. Sensor placement options There are three recommended options for sensor placement: Option Location Notes -------- ---------- ------- Option 1 Back wall Install the sensor on the back wall of the cooling truck Option 2 Ceiling Install the sensor on the ceiling of the cooling truck. Make sure it does not get smashed off while loading the truck Option 3 Back door Install the sensor on the back door of the truck Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal 600px Installation advice for cooling trucks solid solid solid solid Sensor placement diagram showing all three options # Installation advice for glass stillages Source: https://doc.sensolus.com/docs/spec_sheets/asset_specific/glass_stillages Installation advice for glass stillages Optimal installation of a tracker on an asset is very important for the optimal working of the tracking solution. Good installation prolongs the battery lifetime of the tracker, good installation transmits information from the tracker faster to the Sensolus platform, good installation gives more accurate location information,... Installation advice for stillages: Tracker installation Glass stillages come in a variety of shapes and sizes. This manual contains the general guidelines for the installation of trackers on glass stillages. We use a fairly generic stillage form factor for this. Do\'s Don\'ts :----- :------- Install the tracker as high as possible On moving parts (lids, doors) Vertical installation if possible Close to forklift pick up holes Clear view on the sky Under the stillage (bad signal) Use asset’s cavaties to install the tracker On the very outside where the tracker might get hit by other equipment Install between metal ribs Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal Avoid metal surroundings Make sure the tracker is not fully surrounded by metal parts, as this blocks the signal. Protected by cooler shape Protect the tracker by using the cooler unit\'s shape if possible. High position Place the tracker as high as possible on the asset. Clear view on sky Ensure the tracker has a clear view of the sky. Installation advice for stillages solid solid solid solid solid solid solid solid solid tracker placement diagram for glass stillages # Installation advice for roll trailers Source: https://doc.sensolus.com/docs/spec_sheets/asset_specific/roll_trailers Installation advice for roll trailers Optimal installation of a tracker on an asset is very important for the optimal working of the tracking solution. Good installation prolongs the battery lifetime of the tracker, good installation transmits information from the tracker faster to the Sensolus platform, good installation gives more accurate location information,... Installation advice for roll trailers (MAFI): Roll trailers installation advice Do\'s Don\'ts :----- :------- Install the trackers on the front and the back Do not install the trackers on the metal sleepers in between. The signal gets blocked when the MAFI is loaded Installation on the sides is possible but protected from possible damage by other equipment. Do not instal the tracker on moving parts (wrong triggers such as OTM might get triggered and possible tracker damaging) Installion in beams is preferred so they are protected Under the roll trailer (bad signal) Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal Avoid metal surroundings Make sure the tracker is not fully surrounded by metal parts, as this blocks the signal. Protected by cooler shape Protect the tracker by using the cooler unit\'s shape if possible. High position Place the tracker as high as possible on the asset. Clear view on sky Ensure the tracker has a clear view of the sky. Installation advice for roll trailers (MAFI) solid solid solid solid solid solid tracker placement image for roll trailers # Installation advice for RTP's Source: https://doc.sensolus.com/docs/spec_sheets/asset_specific/rtps Installation advice for RTP's Optimal installation of a tracker on an asset is very important for the optimal working of the tracking solution. Good installation prolongs the battery lifetime of the tracker, good installation transmits information from the tracker faster to the Sensolus platform, good installation gives more accurate location information,... Installation advice for RTPs: Tracker installation RTPs can come in a variety of shapes and sizes. This manual contains the general guidelines for the installation of trackers on RTPs. We use a fairly generic RTP form factor for this. Do\'s Don\'ts :----- :------- Install the tracker as high as possible On moving parts (lids, doors) Vertical installation if possible Close to forklift pick up holes Clear view on the sky Under the RTP (bad signal) Use asset’s cavaties to install the tracker On the very outside where the tracker might get hit by other equipment Preferrabley use bolts and nuts to install the tracker Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal Avoid metal surroundings Make sure the tracker is not fully surrounded by metal parts, as this blocks the signal. Protected by cooler shape Protect the tracker by using the cooler unit\'s shape if possible. High position Place the tracker as high as possible on the asset. Clear view on sky Ensure the tracker has a clear view of the sky. Installation advice for RTPs solid solid solid solid solid solid solid solid solid tracker placement diagram for RTPs # Installation advice for sea containers Source: https://doc.sensolus.com/docs/spec_sheets/asset_specific/sea_containers Installation advice for sea containers Optimal installation of a tracker on an asset is very important for the optimal working of the tracking solution. Good installation prolongs the battery lifetime of the tracker, good installation transmits information from the tracker faster to the Sensolus platform, good installation gives more accurate location information,... Installation advice for sea containers: Tracker installation Do\'s Don\'ts :----- :------- Install the tracker as high as possible On moving parts (lids, doors) Vertical installation if possible Close to forklift pick up holes Clear view on the sky Under the stillage (bad signal) Use asset’s cavaties to install the tracker On the very outside where the tracker might get hit by other equipment Install between metal ribs Do not install the tracker inside the container Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal Avoid metal surroundings Make sure the tracker is not fully surrounded by metal parts, as this blocks the signal. Protected by cooler shape Protect the tracker by using the cooler unit\'s shape if possible. High position Place the tracker as high as possible on the asset. Clear view on sky Ensure the tracker has a clear view of the sky. Installation advice for sea containers solid solid solid solid solid solid solid solid solid solid tracker placement diagram for glass stillages # Installation advice for trailers Source: https://doc.sensolus.com/docs/spec_sheets/asset_specific/trailers Installation advice for trailers Optimal installation of a tracker on an asset is very important for the optimal working of the tracking solution. Good installation prolongs the battery lifetime of the tracker, good installation transmits information from the tracker faster to the Sensolus platform, good installation gives more accurate location information,... Installation advice for trailers: Trailers can come in a variety of shapes and sizes. Do\'s Don\'ts :----- :------- Install the tracker as high as possible Not on moving parts or close to the wheels Vertical installation if possible On the front of the trailer Under the chassis (bad signal) Clear view on the sky On the very outside where the tracker might get hit by other equipment Open trailers Flatbed trailers Tarpaulin trailers Install the tracker on the inside of the tarpaulin trailer. Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal Avoid metal surroundings Make sure the tracker is not fully surrounded by metal parts, as this blocks the signal. Protected by cooler shape Protect the tracker by using the cooler unit\'s shape if possible. High position Place the tracker as high as possible on the asset. Clear view on sky Ensure the tracker has a clear view of the sky. Installation advice for trailers solid solid solid solid solid solid solid tracker placement for open trailers tracker placement on flatbed trailers tracker placement on Tarpaulin trailers # Installation advice for waste containers Source: https://doc.sensolus.com/docs/spec_sheets/asset_specific/waste_containers Installation advice for waste containers Optimal installation of a tracker on an asset is very important for the optimal working of the tracking solution. Good installation prolongs the battery lifetime of the tracker, good installation transmits information from the tracker faster to the Sensolus platform, good installation gives more accurate location information,... Installation advice for waste containers: General guidelines - Make sure the tracker is not fully surrounded by metal parts, as this blocks the signal. - Protect the tracker by the container\'s shape if possible: - Between metal ribs - On metal studs - Do not install the tracker on outside sticking parts of the waste container, as the tracker might get damaged by the transport of the waste container. - Keep the picking up and putting down of the waste container in mind. Do not install the tracker close to the pick up parts of the container. - Avoid installation on moving parts of the container at all times. Low pick up containers (skip containers) Do\'s Don\'ts ------ -------- Install the tracker as high as possible On moving parts (lids, doors) Vertical installation if possible Close to the pick up bars Clear view on the sky Under the container (bad signal) Protected by the asset itself (in between metal ribs) On the very outside where the tracker might get hit by other equipment Use bolts and nuts to install the tracker Slanted pick up containers (hook containers) Do\'s Don\'ts ------ -------- As high as possible Not on moving parts (lids, doors) Vertical installation if possible Close to the holes where chains are attached Clear view on the sky Under the container Protected by the asset itself (in between metal ribs) On the side where the tracker might get hit by other equipment Use bolts and nuts to install the tracker On the slanted sides High waste containers Do\'s Don\'ts ------ -------- As high as possible On moving parts (lids, doors) Vertical installation (logo up) Close to the pick up bars Clear view on the sky Under the container Protected by the asset itself (in between metal ribs) On the very outside where the tracker might get hit by other equipment Use bolts and nuts to install the tracker Inside the container Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal 500px 500px 500px Installation advice for waste containers Skip container with tracker placement solid solid solid solid solid solid solid solid solid Hook container with tracker placement solid solid solid solid solid solid solid solid solid solid High waste container with tracker placement solid solid solid solid solid solid solid solid solid solid # Hardware Overview Source: https://doc.sensolus.com/docs/spec_sheets/hardware_overview Complete technical documentation for Sensolus hardware including trackers, sensors, infrastructure and accessories > [!NOTE] > > This section contains comprehensive technical documentation for all Sensolus hardware components. > For product overviews and marketing information, visit the [Sensolus website](https://www.sensolus.com/hardware/) ## What You'll Find Here This hardware documentation section provides detailed technical specifications, installation guides, and reference materials for the complete Sensolus IoT ecosystem. ### Trackers Our core tracking devices designed for various asset types and use cases: * **TRACK Series** - Industrial-grade trackers with multiple connectivity options * **TAG Series** - Compact BLE tags for indoor and short-range tracking Each tracker specification includes power consumption details, environmental ratings, connectivity options, and dimensional drawings. ### Sensors Environmental and operational sensors that integrate with our tracking ecosystem: * **Temperature Sensors** (SENSE-T series) - For cold chain and environmental monitoring * **Humidity & Temperature Sensors** (SENSE-HT series) - Combined environmental sensing * **Current Sensors** (SENSE-CUR series) - For monitoring equipment usage * **Fuel Level Sensors** (SENSE-FL series) - For tank and vehicle monitoring * **Motion Sensors** (SENSE-M series) - For movement and vibration detection ### Infrastructure Gateway and connectivity devices that form the backbone of your tracking network: * **Gateways** (GB series) - Fixed infrastructure for BLE to cellular communication * **Zone Antennas** (ZA series) - For creating detection zones and improving coverage * **Coverage Gateways** (CG series) - Mobile gateway solutions ### Accessories Supporting hardware to complete your installation: * **Battery Packs** - Extended power solutions for various tracker models * **Power Adapters** - Regional power supplies (EU, UK, USA) * **Mounting Solutions** - Magnetic mounts and brackets * **Cables and Connectors** - Connection accessories for different installations ### Asset-Specific Installation Detailed installation guides organized by asset type: * **Installation Manuals** - Step-by-step guides for specific asset types * **Installation Videos** - Visual guides for complex installations * **Drill Templates** - Printable templates for precise mounting * **Best Practices** - Installation tips for optimal performance ## How to Use This Documentation Each hardware component page includes: * **Technical Specifications** - Detailed electrical, mechanical, and environmental specifications * **Dimensional Drawings** - Accurate measurements for installation planning * **Connection Diagrams** - Wiring and connectivity information * **Compliance Information** - Certifications and regulatory compliance details * **Ordering Information** - Part numbers and configuration options > [!TIP] > > Use the navigation menu on the left to browse by hardware category, or use the search function to find specific model numbers or specifications. ## Quick Reference Looking for something specific? * **Comparing tracker models?** Start with the Trackers section * **Need installation guides?** Check Asset-Specific Installation * **Setting up infrastructure?** Browse the Infrastructure section * **Looking for accessories?** Find compatible options in the Accessories section ## Support Resources For additional support: * Technical questions: Contact your Sensolus support representative * Installation assistance: Refer to the asset-specific installation guides * Compatibility questions: Check the technical specifications for supported features # GB 3000 Source: https://doc.sensolus.com/docs/spec_sheets/infrastructure/gb_3000 GB 3000 ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/infrastructure/images/GB-3000.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=c5633d9b3e7bd6b994df867fcb585b09) GB 3000: Installation All mounting options for this device can be found in the Sensolus product mounting instructions. Documentation public GB 3000 BLE Geobeacon Battery-powered Bluetooth Low Energy beacon for indoor asset tracking and zone accuracy optimization. Compatible with all Sensolus trackers equipped with BLE localization, featuring user-replaceable batteries and extended battery life. Bluetooth Low Energy 5 years battery life IP65 rated GB 3000 95 × 45 × 24.5mm 70g (2.5 oz) with batteries Connectivity Technology Bluetooth Low Energy (BLE) beacon Transmission Range Up to 100 meters maximum range \~30 meters standard for indoor geolocation Compatibility Compatible with all Sensolus BLE-equipped trackers Antenna Onboard PCB antenna Physical Characteristics Dimensions 95 × 45 × 24.5mm (3⁴⁷⁄₆₄ × 1⁴⁹⁄₆₄ × 1 in) Weight 70 grams (2.5 oz) with two batteries Color Black IP Rating IP65 Power Power Source Two user-replaceable AA lithium batteries Battery Life Approximately 5 years (depending on operating mode) Mounting Installation Methods Double-sided adhesive tape Bolts/screws Mounting hardware Recommended Orientation Vertical or horizontal with back facing mounting surface Mounting Height Minimum 1.8 meters above ground (as high as possible) SDOC-498608282-125 GB 3000 spec sheet SDOC-498608282-1048 Sensolus product mounting instructions SDOC-498608282-695 3D-file GB 3000 (stp) SDOC-498608282-85 GB 3000 Installations- und Aktivierungsanleitung (DE) SDOC-498608282-86 GB 3000 Installation and activation manual (EN) GB 3000 Installation and Activation Manual: The GB 3000 is a Geobeacon that enables indoor geolocation for your tracked assets. This manual covers the physical installation and platform activation process. Once you have activated a Geobeacon, it MUST be associated with a correct location in the Sensolus platform. Failing to do so may result in trackers not being able to determine their location anymore. Step 1: Place the batteries Step 2: Get the serial number Make sure to write down the serial number of the Geobeacon as you will need it later for platform registration. Step 3: Choose a location Identify the area in which your assets need to be geolocated using this Geobeacon and place the Geobeacon in the middle of that area. Step 4: Install the geobeacon The GB 3000 can be mounted using screws or double-sided tape. Step 5: Verify if the geobeacon works Use the Beaconset+ app to verify that the BLE advertisements are discoverable. You will see the Geobeacon serial number in the list. Move around to verify the covered area. BLE signals and range Sensolus Geobeacons use BLE signals. Water and metal surfaces reflect the Bluetooth signals. Always test the devices in real life circumstances for optimal installation. Range: Depending on the configured signal strength, the Geobeacon will cover an area between 2 meter and 100 meter radius. For indoor geolocation, the standard range is around 30 meters. Installation advice Activation in the platform Once your Geobeacons are properly installed, you need to register and configure them in the Sensolus platform. Sign in to the Sensolus platform and go to Admin → Infrastructure . If your Geobeacons have been pre-assigned to your account, you will see their serial number in the list. Go to the geobeacon you want to configure and edit the settings to give it a useful name. Edit the location: - Type in the approximate address in the search bar and zoom in until you can recognize the place where you physically mounted the Geobeacon. - Click Add geobeacon location and a marker will appear. - Move the marker until it shows the exact place where you installed the Geobeacon. - Click Save to finish. Make sure that your trackers are configured to scan for Geobeacons. This can be done in the tracker configuration page, or Sensolus support can assist with this. sensolus-internal Step 1 - Take parts out Take all parts out of the plastic bag. Step 2 - Open geobeacon Open the geobeacon. Step 3 - Add battery Add the extra battery to the geobeacon. Step 4 - Close geobeacon Close the geobeacon with the small black screws. 200px 300px Mounting with screws \*\*Install with screws:\*\* Use the closing cap, screw, and dowel. The holes are 5 mm and spaced 83 mm apart. Mounting with tape \*\*Install with double-sided tape:\*\* Apply tape to the back of the geobeacon and press firmly against the mounting surface. 300px Installation height \*\*Height:\*\* Install the geobeacon as high as possible, minimum 1.8 meter above the ground. Fixed position \*\*Position:\*\* A Geobeacon is a fixed device that should always remain at the same location. Wrong orientation \*\*Orientation:\*\* Geobeacons are mounted vertically or horizontally with the back facing the mounting surface. All other installations are not recommended. GB 3000 Installation and Activation Manual GB 3000 serial number Choose a location Verify geobeacon with Beaconset+ app Navigate to infrastructure Infrastructure overview Edit geobeacon settings Edit geobeacon settings Set the location Add geobeacon location Configure trackers # ZA 3515 Source: https://doc.sensolus.com/docs/spec_sheets/infrastructure/za_3515 ZA 3515 Battery powered zone anchor ![](https://mintcdn.com/sensolus/WsfN3QaDXu9zn8t8/global-images/hardware_pictures/ZA_3515.png?fit=max\&auto=format\&n=WsfN3QaDXu9zn8t8\&q=85\&s=0a4958f0cbf136b010076690449bed66) ZA 3515: Installation All mounting options for this device can be found in the Sensolus product mounting instructions. Documentation Power Adapters public ZA 3515 NB-IoT/LTE-M Zone Anchor Battery-powered zone anchor for asset localization using Bluetooth tag tracker scanning. Features NB-IoT and LTE-M connectivity with optional AC power adapter support. Includes OTA updates, encrypted communications, and comprehensive diagnostics. NB-IoT LTE-M Bluetooth Low Energy 5.0 IP67 rated IK09 impact resistant Optional AC power adapter ZA 3515 130 × 72 × 36mm 218g (7.68 oz) Connectivity Cellular NB-IoT and LTE-M Europe/North America bands Bi-directional communication Internal omnidirectional antenna Bluetooth Bluetooth Low Energy 5.0 Capabilities Tag tracker scanning Managed geobeacon functionality OTA firmware updates (NB-IoT, LTE-M, BLE) Power Primary Battery User-replaceable Li-SoCl₂ battery (12,000 mAh, 2.94g lithium) Optional AC Adapter 220-230V (Europe) or 110-115V (North America) 2 meter cable 0.1W no-load consumption Physical Characteristics Dimensions 130 × 72 × 36mm (5⅛ × 2⁵³⁄₆₄ × 1²⁷⁄₆₄ in) Weight 218 grams (7.68 oz) Color White Material PBT/PC casing Flame retardant UV stabilized Mounting Holes 7 × 9mm, 115mm center-to-center spacing Environmental IP Rating IP67 Impact Resistance IK09 Operating Temperature -20°C to 60°C (-4°F to 140°F) Drop Shock and Vibration EN 60068 Management & Security User Interaction Magnetic activation LED feedback (green & red) Remote configuration sync Diagnostics Battery lifetime prediction Geolocation diagnostics Communication quality monitoring Security Device-unique encryption keys ChaCha20 end-to-end encryption AES encrypted firmware Signed firmware images only Configuration Configurable Features Tag scanning intervals Scanning thresholds Remote configuration updates Certifications Regulatory CE FCC IC Electrical Safety EN 62368-1 Environmental RoHS compliant, Drop shock testing in progress Mounting Options Supported Methods Rivets Bolts/screws Double-sided tape Tie wraps (6mm) MS Polymer glue Magnet mounting kits SDOC-498608282-1048 Sensolus product mounting instructions SDOC-498608282-1058 Power adaptor Europe SDOC-498608282-1060 Power adaptor USA SDOC-498608282-1077 Power adapter UK Installation and activation manual ZA 3515: Installing the zone achor Attach the zone anchor on the wall Guidelines how to mount the tracker can be found here. Power the zone anchor The zone anchor can operate independently on its internal battery or you can connect the zone anchor to the standard electrical network using a power cable and adapter. If you use the internal battery you can skip this. Activation of the trackers is preferably done with clear skies, and not inside (e.g. factory or warehouse). Trackers are not activated when delivered to your premises. Their subscription in the platform will start within six months of purchase. Activation of the zone anchor Activation of the zone anchors is preferably done with clear skies, and not inside (e.g. factory or warehouse). Zone anchors are not activated when delivered to your premises. Their subscription in the platform will start within six month of purchase. General installation advice Activation of the zone anchors is preferably done with clear skies, and not inside (e.g. factory or warehouse). Zone anchors are not activated when delivered to your premises. Their subscription in the platform will start within six month of purchase. Conditions and surrounding materials Anchor placement for zone detection Force new configuration download on the tracker Troubleshooting 1. Put the magnet on the tracker for less than 5 seconds 2. The possible LED feedback options are: Regulatory Information Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user\'s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This equipment is not suitable for use in locations where children are likely to be present. Industry Canada Statement This device complies with ISED\'s licence-exempt RSSs. Operation is subject to the following two conditions: This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be chosen so that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. RF Exposure Requirements: This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Le présent appareil est conforme aux CNR d\' ISED applicables aux appareils radio exempts de licence. L\'exploitation est autorisée aux deux conditions suivantes: 1. le dispositif ne doit pas produire de brouillage préjudiciable, et 2. ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. Conformément à la réglementation d\'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d\'un type et d\'un gain maximal (ou inférieur) approuvé pour l\'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radio électrique à l\'intention des autres utilisateurs, il faut choisir le type d\'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l\'intensité nécessaire à l\'établissement d\'une communication satisfaisante. Déclaration d\'exposition aux radiations: Cet équipement est conforme aux limites d\'exposition aux rayonnements du Canada établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal ./images/Attach\_connector\_tracker\_1.png ut the cable onto the connector Put the cable onto the connector. Only the black plastic piece will go into the connector. Do not force this ./images/Attach\_connector\_tracker\_2.png Tighten the connection Tighten the connection by gently screwing the cable into the connector. Do not force this as well. ./images/Attach\_connector\_tracker\_3.png Check power connection Check if the power cable is connected well. ./images/Connect\_to\_netpower.png Plug into net power Plug into the netpower. ./images/Activation\_1.png Hold a magnet for about 5 seconds on top of the logo on the zone anchor Hold a magnet for about 5 seconds on top of the logo on the zone anchor. ./images/Activation\_2.png You will first see a red LED. Do not remove the magnet yet. You will first see a red LED. Do not remove the magnet yet. ./images/Activation\_3.png When the green LED is blinking you can remove the magnet. The zone anchor is ready for use. When the green LED is blinking you can remove the magnet. The zone anchor is ready for use. Avoid metal blocking Avoid blocking the tracker\'s view with metal or carbonfibre walls. They weaken or block the radiofrequency signals. Vertical mounting Install the tracker vertically, with the logo facing up. install 3 m high Place the tracker around 3 meter high on a wall to ensure scanning coverage. Concrete has an impact on the range of Bluetooth signals. Concrete has an impact on the range of Bluetooth signals. Water has an impact on the range of Bluetooth signals. Water absorbs the Bluetooth signals, Large amounts of water will impact the range and detectability of the zone anchor. Metal has an impact on the range of Bluetooth signals. Metal reflects the Bluetooth signals, Large amounts of metal will impact the range and detectability of the zone anchor. Place anchors maximum 50 meter apart. ./images/FORCE\_NEW\_CONFIG\_STEP\_1.png Hold magnet Hold a magnet for about 5 seconds on top of the logo on the asset tracker. You will see a green LED. ./images/FORCE\_NEW\_CONFIG\_STEP\_2.png Red and green LED You will see a red and green LED. Now remove the magnet. ./images/FORCE\_NEW\_CONFIG\_STEP\_3.png Green LED blinking Green LED is blinking for minimum 30 seconds. Your tracker is checking for new configurations. ./images/FORCE\_NEW\_CONFIG\_STEP\_4.png Red LED - No new config You see a red LED: No new configuration received. ./images/FORCE\_NEW\_CONFIG\_STEP\_5.png Green LED - New config You see a green LED: New configuration setting received. Red LED Red LED: Tracker is not activated Green LED Green LED: Tracker is activated and working properly No LED No LED: tracker is not functioning (probably dead battery -> contact support) Red LED blinking Red LED is blinking: Tracker is busy Installation and activation manual ZA 3515 Sensolus drill hole template: 115 mm Drilling hole patterns for TRACK 1000 1001 1040 1100 Do not scale this drawing! Print on A4 paper # Platform plans and add-ons Source: https://doc.sensolus.com/docs/spec_sheets/platform_plans_and_addons_comparison Detailed platform plan comparison and add-ons description ## Sensolus product plans Depending on your Sensolus platform subscription plan you will get more or less asset features when logging into the platform. The Sensolus solution comes in 3 plans: Essential, Professional & Analytics. ![](https://mintcdn.com/sensolus/YS3qyMdHjAdnZZ6T/docs/spec_sheets/images/assets_platformplans.png?fit=max\&auto=format\&n=YS3qyMdHjAdnZZ6T\&q=85\&s=0b59c5c29d7e817c50ea543fa23d21d1) Platform plans The focus of the **Essential** product plan is knowing the last reported location, historical locations, and journeys of every asset in the fleet. The **Professional** product plan adds the possibility for geozone visit analysis, stock management & condition monitoring using external sensors. The **Analytics** product plan goes a whole lot further by analyzing the usage patterns of those assets and providing KPIs which allow one to optimize immediately the usage/capacity/distribution of those assets. All platform packages provide APIs to integrate the functionality they provide to external systems. ## Detailed plan information An overview of services and features that are included in the different plans is shown in the table below. | Feature | Essential | Professional | Analytics | | - | - | - | - | | **LOCATION** | | | | | Asset map | x | x | x | | Historic locations & journeys | x | x | x | | Historic location data animation | | | x | | Geo beacons localization | x | x | x | | Private WiFi location resolution | x | x | x | | Address resolution | x | x | x | | Mileage (shortest path estimation) | | | x | | Custom map overlays | | x | x | | Site maps | | x | x | | **GEOZONE** | | | | | Geozone creation | x | x | x | | Import/expert geozones in bulk via Excel/csv | x | x | x | | Geozone inside/outside alert | x | x | x | | Geozone too long/short inside/outside alert | x | x | x | | Geozones overview – list view | x | x | x | | Geozones overview – dashboard - live view | | x | x | | Geozone statistics - dashboard - stock evolution & flows between geozones | | | x | | Single geozone - dashboard - live view | | x | x | | Single geozone - dashboard - stock evolution/dwell times/in-out and flows | | | x | | Geozone visits | | x | x | | **PROCESS FLOW SERVICE** | | | | | Flow creation | | | x | | Flow dashboard | | | x | | Process engine | | | x | | Automation rules | | | x | | **ACTIVITY SERVICE** | | | | | Asset activity dashboard | x | x | x | | **UTILIZATION SERVICE** | | | | | Utilization KPI definition | | | x | | Asset utilization KPI dashboard | | | x | | Fleet utilization KPI dashboard | | | x | | **MAINTENANCE SERVICE** | | | | | Maintenance program creator | | | x | | Asset maintenance dashboard | | | x | | Fleet maintenance dashboard | | | x | | **ENVIRONMENTAL SENSING SERVICE** | | | | | Current and historical sensor data | | x | x | | On-board temperature sensor | | x | x | | External BLE sensors | | x | x | | Asset orientation states/events | | x | x | | Shock detection | | x | x | | Run hours (vibration) | | x | x | | Rotation counting | | x | x | | **MOBILE APP** | | | | | Native Android phone/tablet application | x | x | x | | Native IOS phone/tablet application | x | x | x | | Asset list & map | x | x | x | | Asset journeys and locations | x | x | x | | Guidance towards an asset | x | x | x | | Detect nearby assets using BLE | x | x | x | | Check-in asset location | x | x | x | | **CUSTOM BUSINESS DATA** | | | | | Inject external asset data | | x | x | | **DEVELOPER APIs** | | | | | Pull API | x | x | x | | Push API | x | x | x | | MQTT support | x | x | x | | **GENERIC PLATFORM SERVICE - ALERTING** | | | | | Alert rule configurator | x | x | x | | Active alert list | x | x | x | | Active alert dashboard | | x | x | | Historical alert list | x | x | x | | Historical alert dashboard | | x | x | | Custom email notification subject | | x | x | | Acknowledge and comment alerts | | x | x | | Alert REST push notification | | x | x | | **GENERIC PLATFORM SERVICE – DATA EXPORTING AND REPORTING** | | | | | Report creator | | x | x | | Scheduled reports | | x | x | | Custom report templates | | | x | | Inject externally created reports | | | x | | **GENERIC PLATFORM SERVICE - DASHBOARDING** | | | | | Custom dashboards | x | x | x | | Power BI dashboards | | | x | | Embedded IFRAME dashboards | | | x | | **GENERIC PLATFORM SERVICE – TRACKER CONFIGURATION** | | | | | Tracker settings visualization | x | x | x | | Device usage profile visualization | x | x | x | | Push tracker usage profiles | x | x | x | | **GENERIC PLATFORM SERVICE - COMMUNICATION** | | | | | Data recovery (patented) | x | x | x | | Subscription information | x | x | x | | **GENERIC PLATFORM SERVICE – ASSET SEARCH** | | | | | Quick search (top bar) | x | x | x | | Advanced asset search filtering | x | x | x | | Saving/loading search filters | | x | x | | Export search results as report | | x | x | | **USER MANAGEMENT** | | | | | User management | x | x | x | | Default user roles (viewer, editor, admin) | x | x | x | | Custom user roles | x | x | x | | Audit logs | x | x | x | | **GENERIC PLATFORM SERVICE – CUSTOMIZATION** | | | | | Custom landing page | | x | x | | Custom image & icon library | x | x | x | | Custom orientation states (state mappings) | | x | x | | **QUOTA** | | | | | Device data retention (e.g. location) | 12 months | 24 months | 36 months | | Maximum number of geozones | 50 | 100 | 200 | | Maximum number of alert rules | 10 | 25 | 50 | | Maximum number of scheduled reports | 10 | 15 | 25 | Contact Sensolus if you have requirements that do not match the above quota. ## Sensolus product add-ons Sensolus provides 2 add-ons. They can be used independently from the chosen product subscription plan and come with a fixed recurring price, independent of the number of assets you have. ![](https://mintcdn.com/sensolus/YS3qyMdHjAdnZZ6T/docs/spec_sheets/images/assets_addons.png?fit=max\&auto=format\&n=YS3qyMdHjAdnZZ6T\&q=85\&s=1fa7badd7b12784c5842f579479236ca) Sensolus add-ons The branding add-on allows you to apply your corporate identity to the Sensolus platform. **Branding add-on features** | Feature | Availability | | - | - | | Branded login | x | | Branded application | x | | Branded emails | x | | Custom URL | x | | Branded reports | x | | Language strings override | x | The enterprise security add-on allows you to define authentication and visibility rules tailored to your organization & processes. **Enterprise security add-on features** | Feature | Availability | | - | - | | Single sign-on | x | | Visibility groups | x | # SENSE CUR 4600 Source: https://doc.sensolus.com/docs/spec_sheets/sensors/sense_cur_4600 SENSE CUR 4600 BLE current sensor ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/sensors/images/SENSE-CUR-4600.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=641fe8746d5112678698e9621e0aa895) SENSE CUR 4600: Installation All mounting options for this sensor can be found in the Sensolus product mounting instructions. Documentation public SENSE CUR 4600 BLE DC Current Clamp Sensor Clip-style DC current sensor with BLE connectivity for non-invasive current monitoring. Features configurable thresholds and user-replaceable battery. Ideal for battery-powered equipment and DC circuit monitoring. Bluetooth Low Energy Up to 5 years battery life Flame retardant SENSE CUR 4600 71 × 36 × 36mm 80g (2.8 oz) Current Measurement Measurement Range 0.3A \~ 20A DC Resolution 100mA DC Accuracy ±3% (5-20A DC) Maximum Voltage 900V DC Current Type DC only (cannot measure AC) Sampling Interval Every 30 seconds Connectivity Technology Bluetooth Low Energy (BLE) Transmission Range Up to 35 meters (38 yards) Advertisement Period 2 seconds at +0dBm Physical Characteristics Dimensions 71 × 36 × 36mm Weight 80 grams (2.8 oz) Material NYLON Flame Retardant (UL-94V0) Design Clip-style (no glue or screws required) Power Battery Type CR2477X 3V Lithium battery Battery Life Up to 5 years User Replaceable Yes Configuration Configurable Features Forward current threshold Backward current threshold Configured via Sensolus mobile app Environment & Certifications Operating Temperature -20°C to +50°C IP Rating Not rated for outdoor use Certification CE (Europe) SDOC-498608282-301 SENSE CUR 4600 Installation manual Installation manual for SENSE CUR 4600: Install the batteries Remove the green bottom lid of the clamp sensor. Place the battery with the - pole facing down. Replace the green bottom lid. Install in the machine This sensor is for direct current (DC) measurements only. Open the machine, locate the battery and identify the plus and minus poles. Attach the sensor to one of the cables connected to the plus or the minus pole of the battery. Only one sensor is needed and it does not matter which cable you choose. Make sure the sensor is installed with the correct orientation: - Minus pole wire : The arrow on the sensor points towards the battery - Plus pole wire : The arrow on the sensor points away from the battery Link the sensor to the tracker Use the Sensolus mobile app to link the sensor to a tracker. Make sure you have the latest version of the app installed. Open the Sensolus smartphone app. Select the tracker from the asset list. Click Link sensor at the bottom of the page in the Advanced section. Click the Pair sensor button. Scan the QR code on the sensor. The sensor slots will be automatically assigned. Verify that the sensor is linked. Both charging and uncharging slots should be filled. Adjust threshold values The threshold values can be adjusted for testing purposes using the Sensolus mobile app. Make sure you have the latest version of the app installed. Go to More → Sensor manager . Search for the device you want to edit and click on it to see the details. Click the wheel icon to open the configuration settings. Enter the forward and backward current threshold values, then click the save icon to store the settings. To determine appropriate threshold values, consult the Sensolus documentation centre. Important limitations Keep the following limitations in mind when using the SENSE CUR 4600: Limitation Details ------------ --------- Measurement interval The measurement interval is 30 seconds, and time reporting resolution is in minutes. Short current flows cannot be accurately counted. No live measurements Live current measurements are not available in the platform. No graphing Current vs time graphs are not available in the platform. DC only The sensor cannot measure alternating current (AC) or voltages. Indoor use only The sensor is not IP rated and cannot be used outdoors. Fragile components The clamps contain fragile ferrite cores. Do not drop or hit the sensor. Single wire only Do not put both the + and - wire into the clamp at the same time. The positive and negative magnetic fields will cancel each other out, resulting in no measurement. sensolus-internal 300px 20px 0 300px 20px 0 300px 20px 0 100% 20px 0 250px 20px 0 250px 20px 0 250px 20px 0 250px 20px 0 250px 20px 0 250px 20px 0 250px 20px 0 Installation manual for SENSE CUR 4600 Remove the bottom lid Remove green bottom lid Place the battery Place battery with minus pole down Replace the bottom lid Replace green bottom lid Locate the battery Attach the sensor Verify sensor orientation Sensor wiring diagram showing correct orientation Open the app Select tracker and click Link sensor Click Pair sensor Click Pair sensor button Scan the QR code Scan sensor QR code Verify the link Sensor linked confirmation Open sensor manager Navigate to Sensor manager Find and select the device Select device from list Configure thresholds Configure threshold values # SENSE FL 4300 Source: https://doc.sensolus.com/docs/spec_sheets/sensors/sense_fl_4300 SENSE FL 4300 BLE fill-level radar sensor ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/sensors/images/SENSE-FL-4300.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=fd3fcd33c1360d67e8d532f4aff8aa56) SENSE FL 4300: Installation All mounting options for this sensor can be found in the Sensolus product mounting instructions. Documentation public SENSE FL 4300 BLE Fill-Level Radar Sensor Radar-based distance sensor with BLE connectivity for fill-level measurement and loaded/unloaded state detection. Features configurable measurement intervals, integrated temperature sensor, and optional lid detection. Highly configurable for different material types. Bluetooth Low Energy 5 5 year battery life IP67 rated SENSE FL 4300 Ø 133 × 45 × 21mm 90g (3.2 oz) Sensing & Detection Technology Radar-based distance sensor Detection Range 20cm to 7m Capabilities Fill level measurement Loaded/unloaded state detection Optional lid open/close detection Measurement Interval Configurable (default 60 minutes) Material Detection Highly configurable for different material types Temperature Sensor Range -20°C to 65°C Accuracy ±1.5°C Connectivity Technology Bluetooth Low Energy 5 (BLE 5) Advertisement Frequency Every 3 seconds TX Power Configurable up to +8dBm Physical Characteristics Dimensions Ø 133 × 45 × 21mm Weight 90 grams (3.2 oz) Casing Material PBT/PC UV Stable Mounting Holes Distance 111.5mm Mounting Hole Diameter 4mm IP Rating IP67 Operating Temperature -20°C to +85°C Power Battery Type TITUS ER14335 Primary Lithium Thionyl chloride (SOCl₂) Battery Size ⅔ AA-size, 3.6V, 1.65Ah Battery Life 5 years with default settings User Replaceable Non-replaceable Configuration Configurable Features Measurement interval TX power Material type detection parameters Lid open/close detection Measurement pause on lid open Management Profiles Available upon request SDOC-498608282-1048 Sensolus product mounting instructions Installation manual for SENSE FL 4300: The SENSE FL 4300 has two modes: fill level and load detection. This manual covers installation advice for both modes. Mounting the sensor All mounting options for your sensor can be found in the Sensolus product mounting instructions. Load detection Horizontal mounting When mounting the sensor horizontally for load detection: - Install the sensor in the middle of the load - Install in the middle of the cavity - Install the sensor so it has a 90° angle with the object it has to detect Do not install too close to the side and do not install at an angle. The radio signals can be obstructed and cause false sensor values. Make sure there is a minimum distance of 10 cm between the top of the sensor and the load. Vertical mounting When mounting the sensor vertically for load detection, install with the arrow on the back of the sensor facing up. Fill level Mounting inside an asset When mounting inside a container for fill level detection: - Install the sensor in the middle of the container - Install the sensor so it has a 90° angle with the surface it has to detect Do not install too close to the side and do not install at an angle. The radio signals can be obstructed and cause false sensor values. Make sure there is a minimum distance of 10 cm between the top of the sensor and the load. Mounting outside an asset When mounting outside a container for fill level detection: - Install the sensor in the middle of the container - Install the sensor so it has a 90° angle with the surface it has to detect Do not install too close to the side and do not install at an angle. The radio signals can be obstructed and cause false sensor values. Make sure there is a minimum distance of 10 cm between the top of the sensor and the load. Configuration To configure the sensor profile using the Sensolus app: Go to Admin → Sensors Select the device you want to configure Tap on the settings icon to go to the configuration page Tap the three dots in the top right to open the configuration actions menu In the configuration actions menu tap Profile Select the profile you want to apply to the sensor and tap the save icon on the top right sensolus-internal 300px 20px 0 300px 20px 0 300px 20px 0 200px 20px 0 300px 20px 0 300px 20px 0 300px 20px 0 300px 20px 0 300px 20px 0 Installation manual for SENSE FL 4300 Install sensor in the middle of the load Do not install at the edges Minimum 10cm distance required Back of sensor showing arrow Vertical installation with arrow facing up Install sensor in the middle of the container Install with 90 degree angle Do not install at the edges Minimum 10cm distance required Navigate to sensors Select the device Open settings Open configuration menu Select profile Apply profile # SENSE HT 4050 Source: https://doc.sensolus.com/docs/spec_sheets/sensors/sense_ht_4050 SENSE HT 4050 BLE humidity and temperature sensor ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/sensors/images/SENSE-HT-4050.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=5d773001bf6a1db47703007fcc367c9b) SENSE HT 4050: Installation All mounting options for this sensor can be found in the Sensolus product mounting instructions. Documentation public SENSE HT 4050 BLE Temperature and Humidity Sensor Compact puck-sized BLE sensor for monitoring temperature and humidity across a wide operational range. With food-grade materials and extended battery life, it\'s ideal for environmental monitoring in various applications. Bluetooth Low Energy Up to 7 years battery life IP65 rated SENSE HT 4050 Ø 57mm × 20mm (2¼ in × ²⁵⁄₃₂ in) 41g (1.45 oz) Temperature Monitoring Range -40°C to +85°C (-40°F to 185°F) Accuracy ±0.5°C (±0.8°F) Humidity Monitoring Range 0% to 100% RH Accuracy ±2.5% max (0-90% RH) ±3.5% max (90-100% RH) Connectivity Technology Bluetooth Low Energy (BLE) Transmission Range Up to 60 meters (65 yards) Advertisement Period 2 seconds at +4dBm Physical Characteristics Dimensions Ø 57mm × 20mm (2¼ in × ²⁵⁄₃₂ in) Weight 41 grams (1.45 oz) Casing Material DELRIN (POM C) - Food Grade IP Rating IP65 Mounting Double-sided tape (alternative options documented) Power Battery Type Non-replaceable internal lithium battery (3 VDC) Battery Life Up to 7 years (depending on transmission power) Certifications Europe EN 300 328 EN 301 489 EN 55032 EN 62368-1 CE marked USA FCC 15 Canada ISED RSS-247 ICES-003 Environmental RoHS compliant SDOC-498608282-1048 Sensolus product mounting instructions # SENSE M 4201 Source: https://doc.sensolus.com/docs/spec_sheets/sensors/sense_m_4201 SENSE M 4201 BLE motion sensor ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/sensors/images/SENSE-M-4201.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=17d9fa589ae400ac8abbc018f2b53c69) SENSE M 4201: Installation All mounting options for this sensor can be found in the Sensolus product mounting instructions. Documentation public SENSE M 4201 BLE Magnetic Contact Sensor Small puck-sized magnetic contact sensor with BLE connectivity for detecting open/close events. Features Hall effect sensor technology, immediate state change transmission, and extended battery life. Ideal for door, gate, and container monitoring. Bluetooth Low Energy Up to 7 years battery life IP68 rated SENSE M 4201 Ø 57mm × 20mm (2¼ in × ²⁵⁄₃₂ in) 41g (1.45 oz) sensor + 35g (1.2 oz) magnet Magnetic Detection Sensor Type Hall effect sensor Detection Range 2cm typical (on arrow symbol side) Response Time Immediate transmission upon state change Connectivity Technology Bluetooth Low Energy (BLE) Transmission Range Up to 60 meters (65 yards) Advertisement Period 2 seconds at +4dBm Physical Characteristics - Sensor Dimensions Ø 57mm × 20mm (2¼ in × ²⁵⁄₃₂ in) Weight 41 grams (1.45 oz) Casing Material DELRIN (POM C) - Food Grade (90/128/EEC) IP Rating IP68 Operating Temperature -40°C to +85°C Physical Characteristics - Magnet Dimensions Ø 32mm × 7mm Weight 35 grams (1.2 oz) Power Battery Type Non-replaceable internal lithium battery (3 VDC) Battery Life Up to 7 years (depending on transmission power) Mounting Options Recommended Methods Polyurethane glue Double-sided tape Bolts (M6) Screws Sensor mounting holder (MNT ELA 8140) Certifications Europe EN 300 328 EN 301 489 EN 55032 EN 62368-1 CE marked USA FCC 15.247 FCC PT 15B Canada ISED RSS-247 ICES-003 Environmental RoHS compliant SDOC-498608282-1048 Sensolus product mounting instructions SDOC-498608282-88 Sense M 4201 installation manual EN Installation manual for SENSE M 4201: A sensor and a magnet The magnetic sensor SENSE M 4201 is shipped with a corresponding MAG L 0001. To work correctly it is important that both sensor and magnet are positioned precisely. If they are not correctly aligned, the closed state will never be detected. Component Mounting method Details ----------- ----------------- --------- Sensor See mounting instructions Guidelines for attaching the sensor on the asset can be found in the Sensolus product mounting instructions. Magnet (screws) Screw or M6 bolt Use a screw or M6 bolt to mount the MAG L 0001. The head of the screw should not protrude when you fasten the magnet. Magnet (glue) Industrial glue The magnet can be glued to any flat surface. Use glue when drilling holes is difficult. Advice for the magnet and sensor setup The SENSE M 4201 uses a hall effect sensor to detect the presence of a magnet. In order to be properly detected, the magnet needs to be side by side with the top of the tag, near the logo. On the case, you will see an arrow to show you on which side the magnet should be. If the magnet and sensor are not correctly aligned, the closed state will never be detected. sensolus-internal 250px 20px 0 Installation manual for SENSE M 4201 SENSE M 4201 showing arrow indicator for magnet position # SENSE T 4000 Source: https://doc.sensolus.com/docs/spec_sheets/sensors/sense_t_4000 SENSE T 4000 BLE temperature sensor ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/sensors/images/SENSE-T-4000.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=578bdbc78b004a22ef07a76d465af53e) SENSE T 4000: Installation All mounting options for this sensor can be found in the Sensolus product mounting instructions. Documentation public SENSE T 4000 BLE Temperature Sensor Small puck-sized BLE temperature sensor designed for precise temperature monitoring across a wide range. With its compact form factor and extended battery life, it\'s ideal for various temperature-sensitive applications. Bluetooth Low Energy Up to 7 years battery life IP68 rated SENSE T 4000 Ø 57mm × 20mm (2¼ in × ²⁵⁄₃₂ in) 41g (1.45 oz) Temperature Monitoring Temperature Range -40°C to +85°C (-40°F to 185°F) Accuracy ±0.5°C (±0.8°F) Operating Temperature -40°C to +85°C Connectivity Technology Bluetooth Low Energy (BLE) Transmission Range Up to 60 meters (65 yards) Advertisement Period 2 seconds at +4dBm Physical Characteristics Dimensions Ø 57mm × 20mm (2¼ in × ²⁵⁄₃₂ in) Weight 41 grams (1.45 oz) Casing Material DELRIN (POM C) - Food Grade (90/128/EEC) IP Rating IP68 Mounting Double-sided tape Power Battery Type Non-replaceable internal lithium battery (3 VDC) Battery Life Up to 7 years (depending on transmission power) Certifications Europe EN 300 328 EN 301 489 EN 55032 EN 62368-1 CE marked USA FCC 15.247 FCC PT 15B Canada ISED RSS-247 ICES-003 Environmental RoHS compliant SDOC-498608282-1048 Sensolus product mounting instructions Installation manual for SENSE T 4000: Mounting the sensor All mounting options for your sensor can be found in the Sensolus product mounting instructions. Sensor orientation The SENSE T 4000 has a detection range of 4 meters. Setup in cooler trailers There are three recommended installation locations for cooler trailers: Option Location Notes -------- ---------- ------- Option 1 Back wall Install the sensor on the back wall of the cooling truck. Option 2 Ceiling Install the sensor on the ceiling of the cooling truck. Make sure the sensor does not get damaged during (un)loading. Option 3 Back door Install the sensor on the back door of the truck. sensolus-internal 100% 20px 0 Installation manual for SENSE T 4000 Installation options in cooler trucks # SENSE T 4004 Source: https://doc.sensolus.com/docs/spec_sheets/sensors/sense_t_4004 SENSE T 4004 BLE temperature sensor ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/sensors/images/SENSE-T-4004.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=0a385b84c9ce69ea886347f306a45eae) SENSE T 4004: Installation All mounting options for this sensor can be found in the Sensolus product mounting instructions. Documentation public SENSE T 4004 BLE Temperature Sensor with Probe Compact BLE temperature sensor with external PT1000 probe for precise temperature monitoring across an extended range. Ideal for applications requiring remote temperature measurement with food-grade materials and extended battery life. Bluetooth Low Energy Up to 7 years battery life IP68 probe / IP65 housing SENSE T 4004 Ø 57mm × 20mm (2¼ in × ²⁵⁄₃₂ in) 63g (2.2 oz) Temperature Monitoring Probe Range -80°C to +200°C Accuracy ±0.5°C typical (-30°C to +60°C) ±2°C typical (-80°C to +200°C) Resolution 0.1°C Housing Operating Temperature -40°C to +85°C Probe Specifications Sensor Type PT1000 Connection M8 x 1.0 Dimensions Ø 3mm × 28mm Cable Length 1 meter Material Stainless steel probe Teflon cable insulation IP Rating IP68 Connectivity Technology Bluetooth Low Energy (BLE) Transmission Range Up to 60 meters (65 yards) Advertisement Period 2 seconds at +4dBm Physical Characteristics Housing Dimensions Ø 57mm × 20mm (2¼ in × ²⁵⁄₃₂ in) Weight 63 grams (2.2 oz) Casing Material DELRIN (POM C) - Food Grade Housing IP Rating IP65 Power Battery Type Non-replaceable internal lithium battery (3 VDC) Battery Life Up to 7 years (depending on transmission power) Certifications Europe EN 300 328 EN 301 489 EN 55032 EN 62368-1 EN 12830 CE marked USA FCC certified Canada ISED certified UK UKCA certified Environmental RoHS compliant SDOC-498608282-1048 Sensolus product mounting instructions SDOC-498608282-1113 Sense T 4004 installation manual EN Installation manual for SENSE T 4004: Mounting the sensor All mounting options for your sensor can be found in the Sensolus product mounting instructions. Mounting the probe This is a lab product. The optimal mounting instruction for the probe is still being investigated. At this moment there are no standardized instructions to mount the probe since this is use case specific. Testing the sensor before actual usage is required. Mounting advice for liquid containers You will need quality thermal paste to mount the probe onto the liquid container. Step Action Details ------ -------- --------- Locate the thermal stud Find the stud on the liquids container There is a stud with external thread on the liquids container. Loosen the nut. The thermal probe of the SENSE T 4004 should be attached onto the stud. Mount the probe Apply thermal paste and attach Apply enough thermal paste onto the sensor probe and attach to the stud. Screw the nut back onto the stud. Make sure everything is fastened tightly together. Mount the sensor Position the sensor correctly Mount the sensor in the tank shell, with the probe behind the insulation and the sensor as close as possible to the external cover to ensure BLE connection to a tracker. Fit outer insulation, making sure the pocket is well insulated. Do not use too much insulation. Close up everything. Locate the thermal stud Mount the probe with thermal paste Mount the sensor sensolus-internal 150px 20px 0 flex 20px 20px 0 wrap 1 200px 300px 10px bold 1 200px 300px 10px bold 1 200px 300px 10px bold Installation manual for SENSE T 4004 Thermal paste Locate the thermal stud Mount the probe with thermal paste Mount the sensor # Tracker activation Source: https://doc.sensolus.com/docs/spec_sheets/tracker_activation The best way to activate and install your tracker. ## Tracker activation Tracker activation is needed so it will perform localization and communicate with the platform. Trackers may be shipped in non-activated mode to conserve battery life while they are not effectively deployed. It is also possible that trackers are already activated upon delivery to you - depending on what was requested with the purchase order. For most tracker models, a magnet is used for tracker activation. ![](https://mintcdn.com/sensolus/YIEdQsLzKQopMtjR/docs/spec_sheets/images/illustrations/starterkit/starterkit_activate_tracker.png?fit=max\&auto=format\&n=YIEdQsLzKQopMtjR\&q=85\&s=fc26a7c8bc137875dfe8575603781761) When you activate a tracker the status of the tracker on the platform changes from the ![](https://mintcdn.com/sensolus/YIEdQsLzKQopMtjR/docs/spec_sheets/images/inline_images/inline_status_readyforuse.png?fit=max\&auto=format\&n=YIEdQsLzKQopMtjR\&q=85\&s=ff6d62631b5ccd993ed76adce3b41d29) state to the ![](https://mintcdn.com/sensolus/YIEdQsLzKQopMtjR/docs/spec_sheets/images/inline_images/inline_status_online.png?fit=max\&auto=format\&n=YIEdQsLzKQopMtjR\&q=85\&s=be3e89147fcee61305f1eae55ecf94c1) state. Each time you install a tracker on one of your assets, please make sure to keep track of which tracker (identified by its serial number) is installed on which asset (identified by the asset's identifier). The most effective way to create this link between a particular asset and a particular tracker is by using the [Sensolus mobile application](/docs/mobile_app/mobile_app_overview), where you can scan the tracker's QR code or barcode, and type in or scan the asset's unique identifier as well. It is very important to verify that the tracker that is installed on an asset has been correctly activated, before allowing the asset to be used again. To verify that the tracker has been activated, make sure your tracker has the ![](https://mintcdn.com/sensolus/YIEdQsLzKQopMtjR/docs/spec_sheets/images/inline_images/inline_status_online.png?fit=max\&auto=format\&n=YIEdQsLzKQopMtjR\&q=85\&s=be3e89147fcee61305f1eae55ecf94c1) marker in the Sensolus platform. The Online status should appear within 5 minutes after holding the magnet to the tracker and the green LED blinking has stopped. Before mounting the tracker to the asset it is important to activate the tracker. [https://www.youtube.com/embed/J5EyYQfTWG0?si=urV0JH\_54bhWd2TI](https://www.youtube.com/embed/J5EyYQfTWG0?si=urV0JH_54bhWd2TI) Magnet activation ## Activation troubleshooting It may happen that the tracker does not come immediately (within 5 minutes) online in the Sensolus platform. If this happens, the reason is often that the activation of the network subscription by the operator takes longer than usual (different back-end systems may be involved, depending on the local operator that the tracker is using to connect). If the activation wasn't successful after 5 minutes, the tracker will eventually try to activate again but only after waiting 24 hours (this delay is applied to avoid draining the battery). However, to confirm the correct deployment of the tracker on the asset, it is advisable to ensure that the tracker is online. If after 5 minutes of waiting the status hasn't changed to online yet, hold the magnet again for 5 seconds on top of the tracker to trigger a new activation attempt. These attempts should be repeated until the tracker is online. In rare cases, we have noticed that the activation by operators took several hours to complete. If activation does not succeed after 12 hours, this may indicate another problem - contact support in that case. # TAG 2001 Source: https://doc.sensolus.com/docs/spec_sheets/trackers/tag_2001 TAG 2001 ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/trackers/images/TAG-2001.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=56a34333c5888db2a5a41418830a8d56) For installation instructions, see [Installation instructions](/docs/spec_sheets/installation_instructions). Earlier revision: TAG 2001 spec sheet EN: June 25, 2025 10:10 AM [www.sensolus.com](http://www.sensolus.com) | [info@sensolus.com](mailto:info@sensolus.com) TAG 2001-REV2 40,5 mm 17,6 mm IP67 Water & dust resistance Size 40,5 x 58 x 17.6 mm Weight 22 gram Color White Casing ABS plastic -20°C to +60°C Operating temperature Battery · Up to 10 years battery life, actual battery life may be reduced by extreme temperatures. · User replaceable CR2477Xbatteries Connectivity Mechanics & design Certifications · CE · FCC Mounting Instructions for mounting the device are available in the Sensolus documentation center. · Bluetooth QDID/EPL 58 mm TAG 2001 is a rugged location tag tracker built for reliable, long-term asset tracking in harsh environments. Using Bluetooth Low Energy (BLE) technology, it enables the localization of assets when in range of Sensolus devices with smart BLE gateway capabilities. Up to 10 years of battery life IP67 BLE iBeacon advertising Transmission range Strong emission power (+4dBm) enables detection at ranges of 50m or more. Actual detection range is strongly influenced by physical environment. TAG 2001: Installation All mounting options for this device can be found in the Sensolus product mounting instructions. Documentation public TAG 2001 BLE Location Tag Tracker Rugged location tag tracker built for reliable, long-term asset tracking in harsh environments. Using Bluetooth Low Energy (BLE) technology, it enables the localization of assets when in range of Sensolus devices with smart BLE gateway capabilities. BLE iBeacon advertising Up to 10 years battery life IP67 rated TAG 2001 40.5 × 58 × 17.6mm 22g Connectivity Technology Bluetooth Low Energy (BLE) iBeacon Transmission Range 50 meters or more at +4dBm emission power. Actual detection range is strongly influenced by physical environment. Mechanics & Design Dimensions 40.5 × 58 × 17.6mm Weight 22 grams Color White Casing Material ABS plastic Water & Dust Resistance IP67 Operating Temperature -20°C to +60°C Power Battery Type User replaceable CR2477X batteries Battery Life Up to 10 years. Actual battery life may be reduced by extreme temperatures. Certifications Regulatory CE FCC Bluetooth QDID/EPL Installation and activation manual TAG 2001: Activation The TAG 2001 is already activated when you receive it. No activation steps are required. Verify activation To verify if the tag is activated, perform the following steps in a dark environment: Mounting the TAG 2001 Guidelines for mounting the tracker can be found in the Sensolus Documentation center. Mounting with screws, rivets, or bolts The TAG 2001 has mounting holes for affixing with rivets, screws, or bolts. The spacing between the mounting holes is 49mm. Important mounting warning Do not install the TAG 2001 close to magnets. Magnets can interfere with the tag\'s operation. Edit tag information with the mobile app The Sensolus mobile app allows you to edit the name, tags, and picture of a TAG 2001. Download the Sensolus mobile app from the App Store or Google Play. Open the Sensolus smartphone app and login with your credentials. Go to the tag you want to edit via the asset list, map, or search function. In the search function, use the QR code scanner to open the tag details page. Tap on the edit icon. You can now edit the name, tags, and picture of the tag. Save the settings by tapping the save icon. Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal ./images/tag\_2001\_open.png Open the tag Open the tag by removing the cover. ./images/tag\_2001\_button.png Press the button Press the small button inside the tag. ./images/tag\_2001\_blue\_led.png Blue LED indicator A blue LED will light up, confirming the tag is activated. ./images/tag\_2001\_close.png Close the tag Close the tag again by replacing the cover. 300px 20px 0 300px 20px 0 Installation and activation manual TAG 2001 Mounting hole spacing - 49mm Do not install near magnets Open the app Navigate to the tag Edit the tag Save changes TAG 2001 REV 1 spec sheet EN: January 22, 2024 11:07 AM [www.sensolus.com](http://www.sensolus.com) | [info@sensolus.com](mailto:info@sensolus.com) BLE tag standard TAG 2001-REV1 BLuetooth 5.0 compatible Range up to 60 meter Up to 7 years of battery life IP67 40,5 mm 17,6 mm The standard low-cost BLE tag. IP67 Water & dust resistance Size 40,5 x 58 x 17.6 mm Weight 22 gram Color Black Casing ABS plastic -20°C to +70°C (Battery limit) Operating temperature Battery · Up to 7 years of battery life depending on transmission power · User replaceable CR2477 batteries Connectivity Transmission power Up to 60 meter. BLE advertisement period 4 seconds at + 4dBm Mechanics & design Certifications · CE · FCC Mounting · Double sided tape · Screws · No not mount close to magnets · Bluetooth QDID/EPL 58 mm # TAG 2002 Source: https://doc.sensolus.com/docs/spec_sheets/trackers/tag_2002 TAG 2002 ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/trackers/images/TAG-2002.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=34511d77b1a96413c4ca85dc8b6df78a) For installation instructions, see [Installation instructions](/docs/spec_sheets/installation_instructions). TAG 2002 installation and activation manual EN: [www.sensolus.com](http://www.sensolus.com) | [info@sensolus.com](mailto:info@sensolus.com) Tap on the edit icon ( ). You can now edit the name, tags and picture of the tag. Save the setting by tapping the save icon ( ). Activation and installation manual for TAG 2002 Activation of the TAG 2002 Download and install the Sensolus app from the Apple or Android store. Log in to the app with your Sensolus credentials. Adjust the settings of the Bluetooth tag tracker Click on the search bar. Click on the barcode icon next to the search bar. The camera of your phone will open. Scan the Barcode printed on the front of the BLE tracker. Click on your tracker that will appear in your screen to go to settings. [www.sensolus.com](http://www.sensolus.com) | [info@sensolus.com](mailto:info@sensolus.com) Installing with double sided tape Cleaning the surfaces Clean the area on the asset where you want to add the tag and also the back side of the tag to get rid of any grease/ oil. Sand both surfaces lightly for a few seconds to increase surface area. Clean it again to remove the dust. Installing the Tag 2002 Add the double sided adhesive tape to the tag. Push the tracker into place and push on the tracker\'s top to ensure it is mounted properly. TAG 2002: Installation All mounting options for this device can be found in the Sensolus product mounting instructions. Documentation public TAG 2002 BLE Location Tag Tracker Rugged location tag tracker built for reliable, long-term asset tracking in harsh environments. Using Bluetooth Low Energy (BLE) technology, it enables the localization of assets when in range of Sensolus devices with smart BLE gateway capabilities. BLE iBeacon advertising Up to 10 years battery life IP69K rated TAG 2002 Ø 57mm × 20mm 41g Connectivity Technology Bluetooth Low Energy (BLE) iBeacon Transmission Range 50 meters or more at +4dBm emission power. Actual detection range is strongly influenced by physical environment. Mechanics & Design Dimensions Ø 57mm base, 20mm thickness Weight 41 grams Color White Casing Material DELRIN (POM C) - Compatible with food products (90/128/EEC) Water & Dust Resistance IP69K Operating Temperature -40°C to +85°C Power Battery Type Non-replaceable internal lithium battery (3 VDC) Battery Life Up to 10 years. Actual battery life may be reduced by extreme temperatures. Certifications Europe CE: EN 300 328 / EN 301 489 & EN 55032 / EN 62368-1 USA FCC: 15.247 / FCC PT 15B Canada ISED: RSS-247 / ICES-003 Environmental RoHS compliant # TAG 2006 Source: https://doc.sensolus.com/docs/spec_sheets/trackers/tag_2006 TAG 2006 ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/trackers/images/TAG-2006.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=e18a2518cc54c9ca1d11d593734d48eb) For installation instructions, see [Installation instructions](/docs/spec_sheets/installation_instructions). TAG 2006: Installation All mounting options for this device can be found in the Sensolus product mounting instructions. Documentation public TAG 2006 BLE Location Tag Tracker Rugged location tag tracker built for reliable, long-term asset tracking in harsh environments. Using Bluetooth Low Energy (BLE) technology, it enables the localization of assets when in range of Sensolus devices with smart BLE gateway capabilities. BLE iBeacon advertising Up to 10 years battery life IP67 rated TAG 2006 70 × 46 × 21mm 33.5g Connectivity Technology Bluetooth Low Energy (BLE) iBeacon Transmission Range 50 meters or more at +4dBm emission power. Actual detection range is strongly influenced by physical environment. Mechanics & Design Dimensions 70 × 46 × 21mm Weight 33.5 grams Casing Material PC + ABS Water & Dust Resistance IP67 Operating Temperature -20°C to +60°C Power Battery Type User replaceable lithium coin CR2477 battery Battery Life Up to 10 years. Actual battery life may be reduced by extreme temperatures. Mounting Tamper Protection The battery and internal board can only be reached when the device is unmounted, providing extra tamper protection. Certifications Europe CE-RED, CE-LVD, CE-EMC, REACH USA FCC Environmental RoHS compliant Installation and activation manual TAG 2006: Activation The TAG 2006 is already activated when you receive it. No activation steps are required. Mounting the TAG 2006 Guidelines for mounting the tracker can be found in the Sensolus Documentation center. Mounting with screws, rivets, or bolts The TAG 2006 has mounting holes for affixing with rivets, screws, or bolts. The spacing between the mounting holes is 60mm. Important mounting warning Do not install the TAG 2006 close to magnets. Magnets can interfere with the tag\'s operation. Battery replacement The battery is replaceable in case of defect. The TAG 2006 uses a CR 2477 battery. Edit tag information with the mobile app The Sensolus mobile app allows you to edit the name, tags, and picture of a TAG 2006. Download the Sensolus mobile app from the App Store or Google Play. Open the Sensolus smartphone app and login with your credentials. Go to the tag you want to edit via the asset list, map, or search function. In the search function, use the QR code scanner to open the tag details page. Tap on the edit button. You can now edit the name, tags, and picture of the tag. Save the settings by tapping the save icon. Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal 300px 20px 0 ./images/TAG 2006 BACK BATTERY CHANGE STEP 1.svg Unmount the tag Unmount the tag and put it face down. ./images/TAG 2006 BACK BATTERY CHANGE STEP 2.svg Unscrew the backplate Unscrew the backplate by turning it counterclockwise. ./images/TAG 2006 BACK BATTERY CHANGE STEP 3.svg Replace the battery Replace the empty CR 2477 battery with a new one. ./images/TAG 2006 BACK BATTERY CHANGE STEP 4.svg Screw the backplate back on Screw the backplate on again by turning it clockwise. Installation and activation manual TAG 2006 Mounting hole spacing - 60mm Open the app Navigate to the tag Edit the tag Save changes # TAG 2007 Source: https://doc.sensolus.com/docs/spec_sheets/trackers/tag_2007 TAG 2007 ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/trackers/images/TAG-2007.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=1ef382e18dc11753a1d7ba3a6bee8652) For installation instructions, see [Installation instructions](/docs/spec_sheets/installation_instructions). TAG 2007: Installation All mounting options for this device can be found in the Sensolus product mounting instructions. Documentation public TAG 2007 Compact BLE Location Tag Tracker Compact, tile-shaped location tag tracker particularly useful for applications where space is limited. Using Bluetooth Low Energy (BLE) technology, it enables the localization of assets when in range of Sensolus devices with smart BLE gateway capabilities. BLE iBeacon advertising Up to 4 years battery life IP67 rated TAG 2007 26 × 42 × 6mm 15g Connectivity Technology Bluetooth Low Energy (BLE) iBeacon Transmission Range 50 meters or more at +4dBm emission power. Actual detection range is strongly influenced by physical environment. Mechanics & Design Dimensions 26 × 42 × 6mm Weight 15 grams Color White Casing Material Resin based polymer Water & Dust Resistance IP67 Operating Temperature -20°C to +60°C Power Battery Type User replaceable CR2032 battery Battery Life Up to 4 years depending on transmission power. Activation Method Pull activation strip to activate. Certifications Europe CE USA FCC Canada IC Environmental RoHS compliant Activation and installation manual for TAG 2007: Activation of the TAG 2007 The TAG 2007 is not activated when you receive it. The device comes with a mylar film to prevent battery drainage during storage. Mounting the TAG 2007 The TAG 2007 can be attached using double-sided tape, industrial-grade glue, or tie wraps. See general mounting advice document how to mount the tag. Do not cover the red area with double-sided tape or glue. The green area is suited for double-sided tape or glue. The battery slot is not covered, so replacement is still possible. Replacing batteries When the battery needs to be replaced, follow these steps: Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal ./images/tag\_2007\_mylar\_installed.svg TAG 2007 with mylar film The TAG 2007 is not activated when you receive them. They come with a mylar film to protect battery drainage. ./images/tag\_2007\_remove\_mylar.svg Remove mylar film To power on the TAG 2007, take the mylar film out. ./images/tag\_2007\_led\_blinking.svg Red LED blinking A red LED will keep blinking for 2 seconds. The TAG 2007 is now powered. 250px 20px 0 ./images/tag\_2007\_open\_battery.svg Open battery slot Open the TAG 2007 battery slot. ./images/tag\_2007\_replace\_battery.svg Replace the battery Replace the battery (CR2032). ./images/tag\_2007\_led\_blinking.svg Red LED blinking A red LED will keep blinking for 2 seconds. The TAG 2007 is now powered. Activation and installation manual for TAG 2007 TAG 2007 mounting zones # TAG 2008 Source: https://doc.sensolus.com/docs/spec_sheets/trackers/tag_2008 TAG 2008 ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/trackers/images/TAG-2008.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=0840ccac891a4e084002e8680c2418a5) For installation instructions, see [Installation instructions](/docs/spec_sheets/installation_instructions). TAG 2008: Installation All mounting options for this device can be found in the Sensolus product mounting instructions. Documentation public TAG 2008 Ultra-Compact BLE Location Tag Tracker Very compact location tag tracker that offers a 3 year battery lifetime. Its rugged, physical properties make it very suitable for applications where space is limited and for vibration intensive use cases. It uses Bluetooth Low Energy (BLE) technology and enables asset localization when scanned by Sensolus devices with smart BLE gateway capabilities. BLE iBeacon advertising Up to 3 years battery life IP67 rated TAG 2008 32 × 22 × 5mm 5g Connectivity Technology Bluetooth Low Energy (BLE) iBeacon Transmission Range Up to 20 meters or more at +4dBm emission power. Actual detection range is strongly influenced by physical environment. Mechanics & Design Dimensions 32 × 22 × 5mm Weight 5 grams Color Blue Casing Material Encapsulated in polymer resin Water & Dust Resistance IP67 Operating Temperature -20°C to +60°C Power Battery Type Non-replaceable CR2032 battery Battery Life Up to 3 years. Activation Method The TAG 2008 is already activated out of the box. Certifications Europe CE USA FCC Canada IC Environmental RoHS compliant Activation and installation manual for TAG 2008: Activation of the TAG 2008 The TAG 2008 comes pre-activated from the factory. No additional activation is required. Mounting the TAG 2008 Secure the TAG 2008 using double-sided tape or industrial-grade adhesive. See general mounting advice document for detailed mounting guidelines. Replacing batteries The batteries in the TAG 2008 are non-replaceable. When the battery is depleted, the entire unit must be replaced. Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal Activation and installation manual for TAG 2008 # TRACK 1101 Source: https://doc.sensolus.com/docs/spec_sheets/trackers/track_1101 TRACK 1101 ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/trackers/images/TRACK-1101.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=47a3f2a6c07c83817e07b46dfb18a539) For installation instructions, see [Installation instructions](/docs/spec_sheets/installation_instructions). [https://www.youtube.com/embed/KlTEsmJOdzA](https://www.youtube.com/embed/KlTEsmJOdzA) TRACK1101 Introduction and installation methods TRACK 1101 White: TRACK 1101 White GNSS/Wi-Fi/BLE - NB-IoT The rugged low-power tracker with long battery life with NB-IoT connectivity and guaranteed data recovery. The tracker provides general localization, zone and high precision. The tracker comes with an onboard temperature sensor and shock detection. Compatible with multiple external environmental sensors. The tracker firmware can be upgraded over the air. GNSS Wi-Fi scanning Bluetooth geobeacon for zone precision Quuppa tested for high precision NB-IoT Europe and USA Data recovery IP69K & IP68 IK 09 Flame retardant TRACK 1101 130×72×36 mm 212g (7.6 oz) Connectivity NB-IoT Energy efficient transceiver Internal omnidirectional antenna Bi-directional communication NB-IoT bands: Europe/North America Data recovery OTA firmware upgrade (NB-IoT) Bluetooth Low Energy (BLE) Bluetooth Low Energy 5.0 Geolocalization GNSS Multi GNSS constellation chipset (GPS+GALILEO) BLE Sensolus proximity beacon detection Detectable by zone and high precision anchors Wi-Fi scanning Wi-Fi based geolocalization Wi-Fi 2.4 GHz Sensing Internal Activity monitoring Orientation monitoring Virtual tamper detection Temperature monitoring range: -20°C till 60°C (-4°F to 140°F) typical accuracy: +/- 0.25°C (+/- 0.45°F) worst case accuracy: +/- 1°C (+/- 1.8°F) Configurable shock detection Environmental BLE sensors Temperature, humidity Fill level, contact, magnet Other BLE sensors can be added Activation and mounting Activation and mounting Activation manual Holes 7x9mm (⁹/₃₂ \* ²³/₆₄ in) for screws or rivets. 115 mm (4¹⁷/₃₂ in) distance between the centers of the mounting holes. Instructions for mounting the device are available in the Sensolus documentation center. Mechanics & Design Antennas All antennas are internal Water & dust resistance IP68 & IP69K Size 130x72x36 mm\\n(5⅛ x 2⁵³⁄₆₄ x 1²⁷⁄₆₄ in) Impact resistance IK09 Weight 212 gram (7.6 oz) Drop shock and vibration EN 60068 Color White Operating temperature -20°C to 60°C\\n(-4°F to 140°F)\* The specifics regarding operational temperature are contingent upon the application, installation circumstances, and environmental factors such as sunlight exposure. For further information, please reach out to Sensolus. Battery life can be affected when devices function for extended periods at the extremes of this range. Casing Shell: PBT + PC Cover: PBT GF30% + TPE Flame retardant UV-stabilized Size 130x72x36 mm\\n(5⅛ x 2⁵³⁄₆₄ x 1²⁷⁄₆₄ in) Weight 212 gram (7.6 oz) Water & dust resistance IP68 & IP69K Impact resistance IK09 Operating temperature -20°C to 60°C\\n(-4°F to 140°F)\* Color White Casing Shell: PBT + PC Cover: PBT GF30% + TPE Flame retardant UV-stabilized Battery Standard 3 cell User replaceable battery pack (Li-SoCl₂) 10500 mAh 2.94 gram (0.1037oz) lithium Certifications Regulatory CE FCC IC Bluetooth 5.0 Declaration ID D068598 Environmental IK9 Electrical safety EN 62368-1 User Interaction Device activation Magnetic activation LED feedback Green & red LED feedback on the device Synchronize remote settings Instant: Magnet activation Periodic: No user interaction needed Management Services Diagnostics Battery lifetime prediction Detailed energy consumption Geolocation diagnostics Installation Communication quality Management OTA firmware updates over NB-IoT and BLE Remote configuration Tracker usage profiles External environmental sensors Application services Localization Journeys Activity Utilization Connectable with environmental sensors Temperature detection Tilt detection Shock detection Firmware configuration Communication service Data recovery strategy Communication conditions Location service Motion based,context based, periodic or scheduled Configurable update rate and journey detection Priority sequence (GNSS, Wi-Fi scanning , Bluetooth geobeacon) GNSS fix parameters Quuppa certified for high precision Indoor detection algo Wi-Fi scan strategy BLE scan strategy General configuration Rule engine configuration Diagnostic levels Boot methods Accurate time synchronization Orientation service Orientation detection parameters Environmental sensing Polling and aggregation strategy Alerts Edge processing parameters Activity service Activity detection parameters Tamper service Virtual tamper algo configuration Shock detection Shock algo detection parameters Security Device unique encryption keys End to end payload encryption Chacha 20 AES encrypted firmware Firmware upgrade allows only signed firmware images Management & Security User Interaction Magnetic activation Green & red LED feedback Instant/periodic settings sync Management Services OTA firmware updates Remote configuration Battery lifetime prediction Geolocation diagnostics Security Device unique encryption keys End-to-end ChaCha20 encryption AES encrypted firmware Signed firmware images only \*The specifics regarding operational temperature are contingent upon the application, installation circumstances, and environmental factors such as sunlight exposure. Battery life can be affected when devices function for extended periods at the extremes of this range. Installation and activation manual TRACK 1101 and TRACK 1141: Mounting the tracker Guidelines how to mount the tracker can be found here. Tracker activation Activation of the trackers is preferably done with clear skies, and not inside (e.g. factory or warehouse). Trackers are not activated when delivered to your premises. Their subscription in the platform will start within six months of purchase. Activation troubleshooting Activating a tracker that communicates over the NB-IoT or LTE-M network can sometimes come with a delay. With a delay we mean that the online status doesn\'t appear within 5 minutes after holding the magnet to the tracker. This is mostly due to conditions on the network operator site. If the activation wasn\'t successful after 5 minutes the tracker will try again to activate again after waiting 24 hours. This long period of time is often an obstacle to start installing trackers to assets and makes the timing of the installation of the trackers cumbersome as it is important to only install trackers when they appeared as online on the platform. To overcome to 24 hours waiting time, you can do the following: If after 5 minutes of waiting and the status didn\'t change yet to "online" hold the magnet again for 5 seconds on top of the tracker to enforce a new attempt for activation. Keep trying every 5 minutes until the Online status appears. Installation advice Troubleshooting 1. Put the magnet on the tracker for less than 5 seconds 2. The possible LED feedback options are: Force new configuration download on the tracker Regulatory Information Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user\'s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This equipment is not suitable for use in locations where children are likely to be present. Industry Canada Statement This device complies with ISED\'s licence-exempt RSSs. Operation is subject to the following two conditions: This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be chosen so that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. RF Exposure Requirements: This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Le présent appareil est conforme aux CNR d\' ISED applicables aux appareils radio exempts de licence. L\'exploitation est autorisée aux deux conditions suivantes: 1. le dispositif ne doit pas produire de brouillage préjudiciable, et 2. ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. Conformément à la réglementation d\'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d\'un type et d\'un gain maximal (ou inférieur) approuvé pour l\'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radio électrique à l\'intention des autres utilisateurs, il faut choisir le type d\'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l\'intensité nécessaire à l\'établissement d\'une communication satisfaisante. Déclaration d\'exposition aux radiations: Cet équipement est conforme aux limites d\'exposition aux rayonnements du Canada établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal ./images/Activation\_track\_1101\_step\_1.png Hold magnet on tracker Hold a magnet for about 5 seconds on top of the logo on the asset tracker. ./images/Activation\_track\_1101\_step\_2.png Red LED indicator You will first see a red LED. Do not remove the magnet yet. ./images/Activation\_track\_1101\_step\_3.png Green LED blinking When the green LED is blinking you can remove the magnet. Your tracker is ready for use. Avoid metal blocking Avoid blocking the tracker\'s view with metal or carbonfibre walls. They weaken or block the radiofrequency signals. Mount high Place the tracker as high as possible on the asset to ensure good network coverage. Clean surface Make sure the mounting surface is flat and clean, for a strong and durable bond. Avoid shocks Do not install the tracker on parts that receive frequent shocks or vibrations. Vertical mounting Install the tracker vertically, with the logo facing up. Protected location If your asset is handled in a rough environment, you can place the tracker in a protected location, but never with metal or carbonfibre above the tracker. Clear view Make sure the tracker has a clear view on the sky. Avoid water Avoid placing the tracker in a place that can collect water. Not upside down If you can\'t install vertically, do not mount the tracker upside down. Thermal insulation Place thermal insulation material, such as wood or plastic, between the tracker and the metal asset if the asset produces heat — for example, engines. Red LED Red LED: Tracker is not activated Green LED Green LED: Tracker is activated and working properly No LED No LED: tracker is not functioning (probably dead battery -> contact support) Red LED blinking Red LED is blinking: Tracker is busy ./images/FORCE\_NEW\_CONFIG\_STEP\_1.png Hold magnet Hold a magnet for about 5 seconds on top of the logo on the asset tracker. You will see a green LED. ./images/FORCE\_NEW\_CONFIG\_STEP\_2.png Red and green LED You will see a red and green LED. Now remove the magnet. ./images/FORCE\_NEW\_CONFIG\_STEP\_3.png Green LED blinking Green LED is blinking for minimum 30 seconds. Your tracker is checking for new configurations. ./images/FORCE\_NEW\_CONFIG\_STEP\_4.png Red LED - No new config You see a red LED: No new configuration received. ./images/FORCE\_NEW\_CONFIG\_STEP\_5.png Green LED - New config You see a green LED: New configuration setting received. Installation and activation manual TRACK 1101 and TRACK 1141 Sensolus drill hole template: 115 mm Drilling hole patterns for TRACK 1000 1001 1040 1100 Do not scale this drawing! Print on A4 paper # TRACK 1105 Source: https://doc.sensolus.com/docs/spec_sheets/trackers/track_1105 TRACK 1105 ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/trackers/images/TRACK-1105.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=e2373ef420d80cf8df9ccfeb0e84134e) For installation instructions, see [Installation instructions](/docs/spec_sheets/installation_instructions). TRACK 1105: TRACK 1105 GNSS/Wi-Fi/BLE - NB-IoT/LTE-M The rugged low-power tracker with long battery life with NB-IoT and LTE-M connectivity and guaranteed data recovery. The tracker provides general localization, zone and high precision. The tracker comes with an onboard temperature sensor and shock detection. Compatible with multiple external environmental sensors. The tracker firmware can be upgraded over the air. GNSS Wi-Fi scanning Bluetooth geobeacon for zone precision Quuppa tested for high precision NB-IoT LTE-M Europe and North America Data recovery IP69K & IP68 IK 09 Flame retardant TRACK 1105 130×72×36 mm 212g (7.6 oz) Connectivity NB-IoT and LTE-M Energy efficient transceiver Internal omnidirectional antenna Bi-directional communication NB-IoT and LTE-M bands: Europe/North America Data recovery OTA firmware upgrade (NB-IoT or LTE-M) Connectivity plan TRACK 1105 comes with the Extended connectivity plan Bluetooth Low Energy (BLE) Bluetooth Low Energy 5.0 Geolocalization GNSS Multi GNSS constellation chipset (GPS+GALILEO) BLE Sensolus proximity beacon detection Detectable by zone and high precision anchors Wi-Fi scanning Wi-Fi based geolocalization Wi-Fi 2.4 GHz Sensing Internal Activity monitoring Orientation monitoring Virtual tamper detection Temperature monitoring range: -20°C till 60°C (-4°F to 140°F) typical accuracy: +/- 0.25°C (+/- 0.45°F) worst case accuracy: +/- 1°C (+/- 1.8°F) Configurable shock detection Environmental BLE sensors Temperature, humidity Fill level, contact, magnet Other BLE sensors can be added Activation and mounting Activation and mounting Activation manual Holes 7x9mm (⁹/₃₂ \* ²³/₆₄ in) for screws or rivets. 115 mm (4¹⁷/₃₂ in) distance between the centers of the mounting holes. Instructions for mounting the device are available in the Sensolus documentation center. Mechanics & Design Antennas All antennas are internal Water & dust resistance IP68 & IP69K Size 130x72x36 mm\\n(5⅛ x 2⁵³⁄₆₄ x 1²⁷⁄₆₄ in) Impact resistance IK09 Weight 212 gram (7.6 oz) Drop shock and vibration EN 60068 Color White Operating temperature -20°C to 60°C\\n(-4°F to 140°F)\* The specifics regarding operational temperature are contingent upon the application, installation circumstances, and environmental factors such as sunlight exposure. For further information, please reach out to Sensolus. Battery life can be affected when devices function for extended periods at the extremes of this range. Casing Shell: PBT + PC Cover: PBT GF30% + TPE Flame retardant UV-stabilized Size 130x72x36 mm\\n(5⅛ x 2⁵³⁄₆₄ x 1²⁷⁄₆₄ in) Weight 212 gram (7.6 oz) Water & dust resistance IP68 & IP69K Impact resistance IK09 Operating temperature -20°C to 60°C\\n(-4°F to 140°F)\* Color White Casing Shell: PBT + PC Cover: PBT GF30% + TPE Flame retardant UV-stabilized Battery Standard 3 cell User replaceable battery pack (Li-SoCl₂) 10800 mAh 2.94 gram (0.1037oz) lithium Certifications Regulatory CE FCC IC Bluetooth 5.0 Declaration ID D068598 Environmental Drop shock in progress Electrical safety EN 62368-1 User Interaction Device activation Magnetic activation LED feedback Green & red LED feedback on the device Synchronize remote settings Instant: Magnet activation Periodic: No user interaction needed Management Services Diagnostics Battery lifetime prediction Detailed energy consumption Geolocation diagnostics Installation Communication quality Management OTA firmware updates over NB-IoT,LTE-M and BLE Remote configuration Tracker usage profiles External environmental sensors Application services Localization Journeys Activity Utilization Connectable with environmental sensors Temperature detection Tilt detection Shock detection Firmware configuration Communication service Data recovery strategy Communication conditions Location service Motion based,context based, periodic or scheduled Configurable update rate and journey detection Priority sequence (GNSS, Wi-Fi scanning , Bluetooth geobeacon) GNSS fix parameters Quuppa certified for high precision Indoor detection algo Wi-Fi scan strategy BLE scan strategy General configuration Rule engine configuration Diagnostic levels Boot methods Accurate time synchronization Orientation service Orientation detection parameters Environmental sensing Polling and aggregation strategy Alerts Edge processing parameters Activity service Activity detection parameters Tamper service Virtual tamper algo configuration Shock detection Shock algo detection parameters Security Device unique encryption keys End to end payload encryption Chacha 20 AES encrypted firmware Firmware upgrade allows only signed firmware images Management & Security User Interaction Magnetic activation Green & red LED feedback Instant/periodic settings sync Management Services OTA firmware updates Remote configuration Battery lifetime prediction Geolocation diagnostics Security Device unique encryption keys End-to-end ChaCha20 encryption AES encrypted firmware Signed firmware images only \*The specifics regarding operational temperature are contingent upon the application, installation circumstances, and environmental factors such as sunlight exposure. Battery life can be affected when devices function for extended periods at the extremes of this range. Installation and activation manual TRACK 1105: Mounting the tracker Guidelines how to mount the tracker can be found here. Tracker activation Activation of the trackers is preferably done with clear skies, and not inside (e.g. factory or warehouse). Trackers are not activated when delivered to your premises. Their subscription in the platform will start within six months of purchase. Activation troubleshooting Activating a tracker that communicates over the NB-IoT or LTE-M network can sometimes come with a delay. With a delay we mean that the online status doesn\'t appear within 5 minutes after holding the magnet to the tracker. This is mostly due to conditions on the network operator site. If the activation wasn\'t successful after 5 minutes the tracker will try again to activate again after waiting 24 hours. This long period of time is often an obstacle to start installing trackers to assets and makes the timing of the installation of the trackers cumbersome as it is important to only install trackers when they appeared as online on the platform. To overcome to 24 hours waiting time, you can do the following: If after 5 minutes of waiting and the status didn\'t change yet to "online" hold the magnet again for 5 seconds on top of the tracker to enforce a new attempt for activation. Keep trying every 5 minutes until the Online status appears. Installation advice Troubleshooting 1. Put the magnet on the tracker for less than 5 seconds 2. The possible LED feedback options are: Force new configuration download on the tracker Regulatory Information Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user\'s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This equipment is not suitable for use in locations where children are likely to be present. Industry Canada Statement This device complies with ISED\'s licence-exempt RSSs. Operation is subject to the following two conditions: This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be chosen so that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. RF Exposure Requirements: This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Le présent appareil est conforme aux CNR d\' ISED applicables aux appareils radio exempts de licence. L\'exploitation est autorisée aux deux conditions suivantes: 1. le dispositif ne doit pas produire de brouillage préjudiciable, et 2. ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. Conformément à la réglementation d\'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d\'un type et d\'un gain maximal (ou inférieur) approuvé pour l\'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radio électrique à l\'intention des autres utilisateurs, il faut choisir le type d\'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l\'intensité nécessaire à l\'établissement d\'une communication satisfaisante. Déclaration d\'exposition aux radiations: Cet équipement est conforme aux limites d\'exposition aux rayonnements du Canada établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal ./images/Activation\_track\_1101\_step\_1.png Hold magnet on tracker Hold a magnet for about 5 seconds on top of the logo on the asset tracker. ./images/Activation\_track\_1101\_step\_2.png Red LED indicator You will first see a red LED. Do not remove the magnet yet. ./images/Activation\_track\_1101\_step\_3.png Green LED blinking When the green LED is blinking you can remove the magnet. Your tracker is ready for use. Avoid metal blocking Avoid blocking the tracker\'s view with metal or carbonfibre walls. They weaken or block the radiofrequency signals. Mount high Place the tracker as high as possible on the asset to ensure good network coverage. Clean surface Make sure the mounting surface is flat and clean, for a strong and durable bond. Avoid shocks Do not install the tracker on parts that receive frequent shocks or vibrations. Vertical mounting Install the tracker vertically, with the logo facing up. Protected location If your asset is handled in a rough environment, you can place the tracker in a protected location, but never with metal or carbonfibre above the tracker. Clear view Make sure the tracker has a clear view on the sky. Avoid water Avoid placing the tracker in a place that can collect water. Not upside down If you can\'t install vertically, do not mount the tracker upside down. Thermal insulation Place thermal insulation material, such as wood or plastic, between the tracker and the metal asset if the asset produces heat — for example, engines. Red LED Red LED: Tracker is not activated Green LED Green LED: Tracker is activated and working properly No LED No LED: tracker is not functioning (probably dead battery -> contact support) Red LED blinking Red LED is blinking: Tracker is busy ./images/FORCE\_NEW\_CONFIG\_STEP\_1.png Hold magnet Hold a magnet for about 5 seconds on top of the logo on the asset tracker. You will see a green LED. ./images/FORCE\_NEW\_CONFIG\_STEP\_2.png Red and green LED You will see a red and green LED. Now remove the magnet. ./images/FORCE\_NEW\_CONFIG\_STEP\_3.png Green LED blinking Green LED is blinking for minimum 30 seconds. Your tracker is checking for new configurations. ./images/FORCE\_NEW\_CONFIG\_STEP\_4.png Red LED - No new config You see a red LED: No new configuration received. ./images/FORCE\_NEW\_CONFIG\_STEP\_5.png Green LED - New config You see a green LED: New configuration setting received. Installation and activation manual TRACK 1105 Sensolus drill hole template: 115 mm Drilling hole patterns for TRACK 1000 1001 1040 1100 Do not scale this drawing! Print on A4 paper # TRACK 1105 EX Source: https://doc.sensolus.com/docs/spec_sheets/trackers/track_1105_ex TRACK 1105 EX tracker for hazardous and explosive environments ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/trackers/images/TRACK-1105-EX.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=8a2e6891a98a527c15a08dc6e16035d8) TRACK 1105 EX is the rugged, low-power tracker for hazardous and explosive environments. For installation instructions, see [Installation instructions](/docs/spec_sheets/installation_instructions). TRACK 1105 EX: TRACK 1105 EX GNSS/Wi-Fi/BLE - NB-IoT/LTE-M TRACK 1105 EX is the rugged, low-power tracker for hazardous and explosive environments. With long battery life, NB-IoT and LTE-M connectivity and guaranteed data recovery the tracker provides general localization and zone precision. TRACK 1105 EX comes with an onboard temperature sensor and shock detection. Firmware can be upgraded over the air. GNSS Wi-Fi scanning Bluetooth geobeacon for zone precision NB-IoT LTE-M Europe and North America Data recovery IP69K & IP68 IK 09 Flame retardant TRACK 1105 EX 130×72×36 mm 270g (9.5 oz) Connectivity NB-IoT and LTE-M Energy efficient transceiver Internal omnidirectional antenna Bi-directional communication NB-IoT and LTE-M bands: Europe/North America Data recovery OTA firmware upgrade (NB-IoT or LTE-M) Connectivity plan TRACK 1105 EX comes with the Extended connectivity plan Bluetooth Low Energy (BLE) Bluetooth Low Energy 5.0 Geolocalization GNSS Multi GNSS constellation chipset (GPS+GALILEO) BLE Sensolus proximity beacon detection Detectable by zone anchors Wi-Fi scanning Wi-Fi based geolocalization Wi-Fi 2.4 GHz Sensing Internal Activity monitoring Orientation monitoring Virtual tamper detection Temperature monitoring range: -20°C till 60°C (-4°F to 140°F) typical accuracy: +/- 0.25°C (+/- 0.45°F) worst case accuracy: +/- 1°C (+/- 1.8°F) Configurable shock detection Environmental BLE sensors Temperature, humidity Fill level, contact, magnet Other BLE sensors can be added Activation and mounting Activation and mounting Activation manual Holes 7x9mm (⁹/₃₂ \* ²³/₆₄ in) for screws or rivets. 115 mm (4¹⁷/₃₂ in) distance between the centers of the mounting holes. Instructions for mounting the device are available in the Sensolus documentation center. Mechanics & Design Antennas All antennas are internal Water & dust resistance IP68 & IP69K Size 130x72x36 mm\\n(5⅛ x 2⁵³⁄₆₄ x 1²⁷⁄₆₄ in) Impact resistance IK09 Weight 270 gram (9.5 oz) Drop shock and vibration EN 60068 Color White Operating temperature -20°C to 60°C\\n(-4°F to 140°F)\* The specifics regarding operational temperature are contingent upon the application, installation circumstances, and environmental factors such as sunlight exposure. For further information, please reach out to Sensolus. Battery life can be affected when devices function for extended periods at the extremes of this range. Casing Shell: PBT + PC Cover: PBT GF30% + TPE Flame retardant UV-stabilized Size 130x72x36 mm\\n(5⅛ x 2⁵³⁄₆₄ x 1²⁷⁄₆₄ in) Weight 270 gram (9.5 oz) Water & dust resistance IP68 & IP69K Impact resistance IK09 Operating temperature -20°C to 60°C\\n(-4°F to 140°F)\* Color White Casing Shell: PBT + PC Cover: PBT GF30% + TPE Flame retardant UV-stabilized Battery Standard 3 cell Non-replaceable battery pack (Li-SoCl₂) 10800 mAh 2.94 gram (0.1037oz) lithium Certifications Regulatory CE FCC IC Bluetooth 5.0 Declaration ID D068598 Environmental Drop shock in progress Electrical safety EN 62368-1 User Interaction Device activation Magnetic activation LED feedback Green & red LED feedback on the device Synchronize remote settings Instant: Magnet activation Periodic: No user interaction needed Management Services Diagnostics Battery lifetime prediction Detailed energy consumption Geolocation diagnostics Installation Communication quality Management OTA firmware updates over NB-IoT,LTE-M and BLE Remote configuration Tracker usage profiles External environmental sensors Application services Localization Journeys Activity Utilization Connectable with environmental sensors Temperature detection Tilt detection Shock detection Firmware configuration Communication service Data recovery strategy Communication conditions Location service Motion based,context based, periodic or scheduled Configurable update rate and journey detection Priority sequence (GNSS, Wi-Fi scanning , Bluetooth geobeacon) GNSS fix parameters Indoor detection algo Wi-Fi scan strategy BLE scan strategy General configuration Rule engine configuration Diagnostic levels Boot methods Accurate time synchronization Orientation service Orientation detection parameters Environmental sensing Polling and aggregation strategy Alerts Edge processing parameters Activity service Activity detection parameters Tamper service Virtual tamper algo configuration Shock detection Shock algo detection parameters Security Device unique encryption keys End to end payload encryption Chacha 20 AES encrypted firmware Firmware upgrade allows only signed firmware images Management & Security User Interaction Magnetic activation Green & red LED feedback Instant/periodic settings sync Management Services OTA firmware updates Remote configuration Battery lifetime prediction Geolocation diagnostics Security Device unique encryption keys End-to-end ChaCha20 encryption AES encrypted firmware Signed firmware images only \*The specifics regarding operational temperature are contingent upon the application, installation circumstances, and environmental factors such as sunlight exposure. Battery life can be affected when devices function for extended periods at the extremes of this range. TRACK 1105 EX user manual: TRACK 1105 EX User Manual Technical data Installation guide Certifications [www.sensolus.com](http://www.sensolus.com) Sensolus NV Moutstraat 54 9000 Gent Belgium UM-TRACK1105EX-001 UM-TRACK1105EX-001 [www.sensolus.com](http://www.sensolus.com) © 2026 [www.sensolus.com](http://www.sensolus.com) August 6, 2026 12:05 PM Version: 1.0 2 1. Revision history Contents version author publishing date reason of revision 1.0 Sensolus NV 06 August 2026 Initial version 1. Revision history 2 2. Technical data 3 3. Certifications and statements 4 4. Product information 5 4.1. Safety notice 5 4.2. Function description 5 4.3. Installation safety instructions 5 4.4.Replacing batteries 5 4.5.Label information 5 5. Special conditions of Use (X) 5 6. Device installation and mounting guide 6 6.1. Recommended installation equipment 6 6.2. Device outline and mounting 6 6.3. Mounting advice for optimal working 6 7. Tracker activation, troubleshooting and downloading a new device configuration 7 7.1. Tracker activation 7 7.2. Activation delays 7 7.3. Troubleshooting 7 7.4 Download a new configuration on the tracker 8 UM-TRACK1105EX-001 [www.sensolus.com](http://www.sensolus.com) © 2026 [www.sensolus.com](http://www.sensolus.com) August 6, 2026 12:05 PM Version: 1.0 3 Product TRACK 1105 EX Physical \* The specifics regarding operational temperature are contingent upon the application, installation circumstances, and environmental factors such as sunlight exposure. Size 130x72x36 mm Weight 270 gram Mounting hole spacing 115 mm Environmental Operating temperature -20°C to 60°C (-4°F to 140°F) \* Ingress protection IP68 & IP69K Maximum operational altitude • ATEX: 2000 m • IECEx: 4000 m Energy Battery type Li-SoCl2 Nominal battery voltage 3.6V Battery capacity 10800 mAh Replacable battery No Shock detection Range 16g GNSS Supported networks GPS + GALILEO Cellular NB-IoT frequency bands B1, B2, B3, B4, B5, B8, B12, B13, B17, B19, B20, B25, B26, B28, B65, B66, B85. B106 LTE-M frequency bands B1, B2, B3, B4, B5, B8, B12, B13, B18, B19, B20, B25, B26, B28, B66, B85, B106 Bluetooth Low Energy (BLE) Bluetooth Low Energy 5 Wi-Fi scanning Wi-Fi based geolocalization Wi-Fi 2.4 GHz Lifetime Maintenance free Up to 10 years, depending on environmental conditions and use of the device. Impact protection rating IK09 2. Technical data UM-TRACK1105EX-001 [www.sensolus.com](http://www.sensolus.com) © 2026 [www.sensolus.com](http://www.sensolus.com) August 6, 2026 12:05 PM Version: 1.0 4 Environment • Dust Ingress Test IP6X: EN 60529:1992+A2:2013 • Water Ingress Test IPX8: EN 60529:1992+A2:2013 • Water Ingress Test IPX9: EN 60529:1992+A2:2013 • Mechanical IMPACT IK09: EN 62262:2002+A1:2021 • Random Vibration Test: EN 60068-2-64:2008 +A1:2019 Test Fh • Mechanical Shock Test: EN 60068-2-27:2009 Test Ea • ROHS • REACH ATEX & IECEx • ATEX Certifate Number DEKRA 26ATEX0011X • IECEx Certifcate Number IECEx DEK 26.0004X • Directive 2014/34/EU • EN 60079-0 and IEC 60079-0 • EN 60079-11 and IEC 60079-11 • II 2 GD Ex ib IIC T4 Gb Ex ib IIIC T135°C Db Product safety • IEC 62368-1:2023 Radio equipment and EMC • EN 300 328 V2.2.2 • EN 301 908-1 V15.2.1 • EN 301 908-13 V13.2.1 • EN 303 413 V1.2.1 • EN 55032:2015 +A11:2020 • EN 301 489-1 V2.2.3 • EN 301 489-17 V3.2.4 • EN 301 489-19 V2.2.1 • EN 301 489-52 V1.2.1 USA FCC ID: 2AT4V-HATICOMBO This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION TO USERS Changes or modifications not expressly approved by the party responsible for compliance could void the user\`s authority to operate the equipment. Canada IC: 26629-HATICOMBO This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence- exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) L’appareil ne doit pas produire de brouillage; (2) L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. 3. Certifications and statements UM-TRACK1105EX-001 [www.sensolus.com](http://www.sensolus.com) © 2026 [www.sensolus.com](http://www.sensolus.com) August 6, 2026 12:05 PM Version: 1.0 5 4. Product information 4.1. Safety notice 1. Do not open the device. 2. Do not drop the device. 3. Do not change the batteries. 4. Do not expose device to conditions other than those in chapter “Technical Data”. 4.3. Installation safety instructions 4.2. Function description TRACK 1105 EX is rugged low-power asset tracker with NB-IoT and LTE-M connectivity and guaranteed data recovery. The tracker provides general localization, zone and high precision. TRACK 1105 EX comes with an onboard temperature sensor and shock detection. Compatible with multiple external environmental sensors. The tracker firmware can be upgraded over the air. The battery cannot be replaced and lasts around 10 years. Only permitted to install the Sensolus TRACK 1105 EX in hazardous areas applicable to the certificate . Before installing the device at the intended location, verify that drilling mounting holes will not damage the mechani­ cal structure of the equipment. If uncertain, consult the equipment manufacturer to determine appropriate mounting locations. Batteries cannot be replaced. 4.4.Replacing batteries 5. Special conditions of Use (X) 4.5.Label information Serial number Model WARNING – POTENTIAL ELECTROSTATIC CHARGE HAZARD • The enclosure is made of non-metallic material and may present an electrostatic charging hazard. • The equipment shall be installed as a fixed installation. • The equipment shall be installed in a location where electrostatic charge build-up is avoided (e.g. flowing dust, high air flow, rubbing surfaces). • Cleaning shall only be performed with a damp cloth. Do not clean with a dry cloth. Ex marking Certificate Manufacturing date code in YYWW format Manufacturer UM-TRACK1105EX-001 [www.sensolus.com](http://www.sensolus.com) © 2026 [www.sensolus.com](http://www.sensolus.com) August 6, 2026 12:05 PM Version: 1.0 6 6.2. Device outline and mounting 6.3. Mounting advice for optimal working Avoid blocking the tracker’s view with metal or carbonfibre walls. They weaken or block the radiofrequency signals. Place the tracker has high as possible on the asset to ensure good network coverage. Make sure the mounting surface is flat and clean, for a strong and durable bond. Do not install the tracker on parts that receive frequent shocks or vibrations. Install the tracker vertically, with the logo facing up. If your asset is handled in a rough environment, you can place the tracker in a protected location, but never with metal or car­ bonfibre above the tracker. Make sure the tracker has a clear view on the sky. Avoid placing the tracker in a place that can collect water. If you can\'t install vertically, do not mount the tracker upside down. It is advisable to place a thermal insulation material, such as wood or plastic, between the tracker and the metal asset if the latter is subjected to prolonged exposure to sunlight. Height Mounting hole distance (115 mm) Top of the device facing the sky Device label 6. Device installation and mounting guide Guidelines how to mount the tracker can be found in the Sensolus documentation center. Sensolus allows different mounting methods. Installation of the device must only be done by appropriately qualified personnel. 6.1. Recommended installation equipment UM-TRACK1105EX-001 [www.sensolus.com](http://www.sensolus.com) © 2026 [www.sensolus.com](http://www.sensolus.com) August 6, 2026 12:05 PM Version: 1.0 7 7.3. Troubleshooting 1. Put the magnet on the tracker for less than 5 seconds 2. The possible LED feedback options are: Red LED: Tracker is not activated Green LED: Tracker is activated and working properly No LED: tracker is not functioning (probably dead battery -> contact support) Red LED is blinking: Tracker is busy Activation of the trackers is preferably done with clear skies, and not inside (e.g. factory or warehouse). Trackers are not activated when delivered to your premises. Their subscription in the platform will start within six month of purchase. Hold a magnet for about 5 seconds on top of the logo on the asset tracker. 7. Tracker activation, troubleshooting and downloading a new device configuration You will first see a red LED. Do not remove the magnet yet. When the green LED is blinking you can remove the magnet. Your tracker is ready for use. Activating a tracker that communicates over the NB-IoT or LTE-M network can sometimes come with a delay. With a delay we mean that the online status doesn\'t appear within 5 minutes after holding the magnet to the tracker. This is mostly due to conditions on the network operator site. If the activation wasn\'t successful after 5 minutes the tracker will try again to activate again after waiting 24 hours. This long period of time is often an obstacle to start installing trackers to assets and makes the timing of the installation of the trackers cumbersome as it is important to only install trackers when they appeared as online on the platform. To overcome to 24 hours waiting time, you can do the following: if after 5 minutes of waiting and the status didn\'t change yet to "online\'\' hold the magnet again for 5 seconds on top of the tracker to enforce a new attempt for activation. Keep trying every 5 minutes until the Online status appears. 7.1. Tracker activation 7.2. Activation delays UM-TRACK1105EX-001 [www.sensolus.com](http://www.sensolus.com) © 2026 [www.sensolus.com](http://www.sensolus.com) August 6, 2026 12:05 PM Version: 1.0 8 7.4 Download a new configuration on the tracker You will see a green LED. You will see a red and green Hold a magnet for about 5 seconds on top of the logo on LED. the asset tracker. Now remove the Magnet Green LED is blinking for minimum 30 seconds. Your tracker is checking for new configurations You see a red LED: No new configuration received You see a green LED: New configuration setting received Sensolus drill hole template: 115 mm Drilling hole patterns for TRACK 1000 1001 1040 1100 Do not scale this drawing! Print on A4 paper # TRACK 1105 IF Source: https://doc.sensolus.com/docs/spec_sheets/trackers/track_1105_if TRACK 1105 IF ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/trackers/images/TRACK-1105-IF.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=b4163e2fdf78c184ae87a4c1635b3ed5) For installation instructions, see [Installation instructions](/docs/spec_sheets/installation_instructions). ## How TRACK 1105 IF works The tracker uses an **in-flight detection algorithm** that automatically detects takeoff. On detection, it **auto-disables all radio transmissions** for the duration of the flight and powers radio back on after landing. Aviation-safe hardware design: * **Battery:** 5200 mAh + hybrid capacitor, lithium content under 2 g — below IATA/ICAO air transport threshold * **Casing:** dedicated pressure monitoring sensor with 2 vent holes ## Certifications * **DO-160G** — aviation environmental test certification (vibration, altitude, temperature, EMC for airborne hardware). This is the legal minimum for any electronic device on a commercial aircraft. * **IATA approval** — a recognized industry framework that helps streamline the path toward carrier acceptance. See the [IATA ONE Source listing](https://onesource.iata.org/s/station-profile?eid=aDQc40000005rIDGAY). * **Airline-specific acceptance** — on top of IATA, individual airlines may require their own approval. Currently approved by: **AeroLogic**, **Air Canada**, **American Airlines**, **Avianca Cargo**, **Challenge Group**, **FedEx Cargo**, **Icelandair Cargo**, **Korean Air**, **Lufthansa Cargo**, **Qatar Airways**. Let us know which airline(s) are relevant to your use case so we can follow up on the required approvals. TRACK 1105 IF: /docs/pdf\_authoring/images/sensolus-logo-white.svg TRACK 1105 IF GNSS/Wi-Fi/BLE - NB-IoT/LTE-M The rugged low-power tracker with long battery life with NB-IoT and LTE-M connectivity and guaranteed data recovery. The tracker provides general localization, zone and high precision. The tracker comes with an onboard temperature sensor and shock detection. Compatible with multiple external environmental sensors. The tracker firmware can be upgraded over the air. This tracker is DO-160 certified. GNSS Wi-Fi scanning Bluetooth geobeacon for zone precision NB-IoT LTE-M In flight certified Extended connectivity plan Data recovery IP65 & IP38 in progress IK 09 in progress Flame retardant TRACK 1105 IF 130×72×36 mm 212g (7.6 oz) Connectivity NB-IoT / LTE-M Energy efficient transceiver Internal omnidirectional antenna Bi-directional communication Data recovery OTA firmware upgrade (NB-IoT/LTE-M) Bluetooth Low Energy (BLE) Bluetooth Low Energy 5.0 Connectivity plan TRACK 1105 IF has the extended connectivity plan. Geolocalization GNSS Multi GNSS constellation chipset (GPS+GALILEO) BLE Sensolus proximity beacon detection Detectable by zone anchors Wi-Fi scanning Wi-Fi based geolocalization Wi-Fi 2.4 GHz Sensing Internal Activity monitoring Orientation monitoring Virtual tamper detection Temperature monitoring range: -20°C till 60°C (-4°F to 140°F) typical accuracy: +/- 0.25°C (+/- 0.45°F) worst case accuracy: +/- 1°C (+/- 1.8°F) Configurable shock detection Environmental BLE sensors Temperature & humidity Other BLE sensors can be requested Mechanics & Design Antennas All antennas are internal Water & dust resistance IP65 & IP68 Size 130x72x36 mm\\n(5⅛ x 2⁵³⁄₆₄ x 1²⁷⁄₆₄ in) Impact resistance IK09 in progress Weight 205 gram (7.23 oz) Drop shock and vibration EN 60068 Color White Operating temperature -20°C to 60°C\\n(-4°F to 140°F)\* The specifics regarding operational temperature are contingent upon the application, installation circumstances, and environmental factors such as sunlight exposure. For further information, please reach out to Sensolus. Battery life can be affected when devices function for extended periods at the extremes of this range. Casing Shell: PBT/PC 29 TM-Z2 FR UV LS Flame retardant UV-stabilized Battery Standard 3 cell User replaceable battery pack (Li-SoCl2) 5200mAh + hybrid capacitor 1.44 gram (0.0507 oz) lithium, 2 cells of 0.72 gram (0.0253 oz) Compliant with 49 CFR 172.102 Special Provision 388 Certifications Regulatory In progress Bluetooth 5.0 Declaration ID in progress DO-160 Section 21 category H EASA AMC1 CAT.GEN.MPA.140 (d)(3)(ii)(B) Battery certifications UN 38.3 UL 1642 User Interaction Device activation Magnetic activation LED feedback Green & red LED feedback on the device Synchronize remote settings Instant: Magnet activation Periodic: No user interaction needed Management Services Diagnostics Battery lifetime prediction Detailed energy consumption Geolocation diagnostics Installation Communication quality Management OTA firmware updates over NB-IoT/LTE-M and BLE Remote configuration Tracker usage profiles External environmental sensors Application services Localization Journeys Activity Utilization Temperature detection Connectable with environmental sensors Tilt detection Shock detection Firmware configuration Communication service Data recovery strategy Communication conditions Smart switching between LTE-M and NB-IoT Location service Motion based,context based, periodic or scheduled Configurable update rate and journey detection Priority sequence (GNSS, Wi-Fi scanning , Bluetooth geobeacon) GNSS fix parameters Indoor detection algo Wi-Fi scan strategy BLE scan strategy General configuration Rule engine configuration Diagnostic levels Boot methods Accurate time synchronization Orientation service Orientation detection parameters Environmental sensing Polling and aggregation strategy Alerts Edge processing parameters Activity service Activity detection parameters Tamper service Virtual tamper algo configuration Shock detection Shock algo detection parameters In flight detection (T-PED tolerant aircraft) AMC1 CAT.GEN.MPA.140 (d)(3)(ii)(A)(a) & (d)(3)(ii)(A)(b) AC91.21-1D chapter 10 Security Device unique encryption keys End to end payload encryption Chacha 20 AES encrypted firmware Firmware upgrade allows only signed firmware images Note: Use of our tracking solution with third-party shipping, courier, and logistics services might be subject to those providers\' applicable terms and conditions. Users are responsible for reviewing and complying with all relevant third-party terms. Sensolus makes no representations regarding and assumes no liability for third-party terms or services, nor for any user non-compliance with third-party terms. \*The specifics regarding operational temperature are contingent upon the application, installation circumstances, and environmental factors such as sunlight exposure. Battery life can be affected when devices function for extended periods at the extremes of this range. Installation and activation manual TRACK 1105 IF: Mounting the tracker Guidelines how to mount the tracker can be found here. Tracker activation Activation of the trackers is preferably done with clear skies, and not inside (e.g. factory or warehouse). Trackers are not activated when delivered to your premises. Their subscription in the platform will start within six months of purchase. Activation troubleshooting Activating a tracker that communicates over the NB-IoT or LTE-M network can sometimes come with a delay. With a delay we mean that the online status doesn\'t appear within 5 minutes after holding the magnet to the tracker. This is mostly due to conditions on the network operator site. If the activation wasn\'t successful after 5 minutes the tracker will try again to activate again after waiting 24 hours. This long period of time is often an obstacle to start installing trackers to assets and makes the timing of the installation of the trackers cumbersome as it is important to only install trackers when they appeared as online on the platform. To overcome to 24 hours waiting time, you can do the following: If after 5 minutes of waiting and the status didn\'t change yet to "online" hold the magnet again for 5 seconds on top of the tracker to enforce a new attempt for activation. Keep trying every 5 minutes until the Online status appears. Installation advice Troubleshooting 1. Put the magnet on the tracker for less than 5 seconds 2. The possible LED feedback options are: Force new configuration download on the tracker Regulatory Information Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user\'s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This equipment is not suitable for use in locations where children are likely to be present. Industry Canada Statement This device complies with ISED\'s licence-exempt RSSs. Operation is subject to the following two conditions: This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be chosen so that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. RF Exposure Requirements: This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Le présent appareil est conforme aux CNR d\' ISED applicables aux appareils radio exempts de licence. L\'exploitation est autorisée aux deux conditions suivantes: 1. le dispositif ne doit pas produire de brouillage préjudiciable, et 2. ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. Conformément à la réglementation d\'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d\'un type et d\'un gain maximal (ou inférieur) approuvé pour l\'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radio électrique à l\'intention des autres utilisateurs, il faut choisir le type d\'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l\'intensité nécessaire à l\'établissement d\'une communication satisfaisante. Déclaration d\'exposition aux radiations: Cet équipement est conforme aux limites d\'exposition aux rayonnements du Canada établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Note: Use of our tracking solution with third-party shipping, courier, and logistics services might be subject to those providers\' applicable terms and conditions. Users are responsible for reviewing and complying with all relevant third-party terms. Sensolus makes no representations regarding and assumes no liability for third-party terms or services, nor for any user non-compliance with third-party terms. Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal ./images/Activation\_track\_1101\_step\_1.png Hold magnet on tracker Hold a magnet for about 5 seconds on top of the logo on the asset tracker. ./images/Activation\_track\_1101\_step\_2.png Red LED indicator You will first see a red LED. Do not remove the magnet yet. ./images/Activation\_track\_1101\_step\_3.png Green LED blinking When the green LED is blinking you can remove the magnet. Your tracker is ready for use. Avoid metal blocking Avoid blocking the tracker\'s view with metal or carbonfibre walls. They weaken or block the radiofrequency signals. Mount high Place the tracker as high as possible on the asset to ensure good network coverage. Clean surface Make sure the mounting surface is flat and clean, for a strong and durable bond. Avoid shocks Do not install the tracker on parts that receive frequent shocks or vibrations. Vertical mounting Install the tracker vertically, with the logo facing up. Protected location If your asset is handled in a rough environment, you can place the tracker in a protected location, but never with metal or carbonfibre above the tracker. Clear view Make sure the tracker has a clear view on the sky. Avoid water Avoid placing the tracker in a place that can collect water. Not upside down If you can\'t install vertically, do not mount the tracker upside down. Thermal insulation Place thermal insulation material, such as wood or plastic, between the tracker and the metal asset if the asset produces heat — for example, engines. Red LED Red LED: Tracker is not activated Green LED Green LED: Tracker is activated and working properly No LED No LED: tracker is not functioning (probably dead battery -> contact support) Red LED blinking Red LED is blinking: Tracker is busy ./images/FORCE\_NEW\_CONFIG\_STEP\_1.png Hold magnet Hold a magnet for about 5 seconds on top of the logo on the asset tracker. You will see a green LED. ./images/FORCE\_NEW\_CONFIG\_STEP\_2.png Red and green LED You will see a red and green LED. Now remove the magnet. ./images/FORCE\_NEW\_CONFIG\_STEP\_3.png Green LED blinking Green LED is blinking for minimum 30 seconds. Your tracker is checking for new configurations. ./images/FORCE\_NEW\_CONFIG\_STEP\_4.png Red LED - No new config You see a red LED: No new configuration received. ./images/FORCE\_NEW\_CONFIG\_STEP\_5.png Green LED - New config You see a green LED: New configuration setting received. Installation and activation manual TRACK 1105 IF Sensolus drill hole template: 115 mm Drilling hole patterns for TRACK 1000 1001 1040 1100 Do not scale this drawing! Print on A4 paper # TRACK 1115 Source: https://doc.sensolus.com/docs/spec_sheets/trackers/track_1115 TRACK 1115 ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/trackers/images/TRACK_1115.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=d9b2b36443633cd7c85854dae1cc00fa) For installation instructions, see [Installation instructions](/docs/spec_sheets/installation_instructions). TRACK 1115: Installation All mounting options for this device can be found in the Sensolus product mounting instructions. TRACK 1115 GNSS/Wi-Fi/BLE - NB-IoT/LTE-M The small low-power tracker with long battery life. Indoor and outdoor localization, zone and high precision. Compatible with multiple external environmental sensors. GNSS Wi-Fi scanning Bluetooth geobeacon for zone precision NB-IoT LTE-M Europe and North America Data recovery IP68 Flame retardant TRACK 1115 105×54×21.5 mm 95g (7.6 oz) Connectivity NB-IoT and LTE-M Energy efficient transceiver Internal omnidirectional antenna Bi-directional communication NB-IoT and LTE-M bands: Europe/North America Data recovery OTA firmware upgrade (NB-IoT or LTE-M) Connectivity plan TRACK 1115 comes with the Extended connectivity plan Bluetooth Low Energy (BLE) Bluetooth Low Energy 5.0 Geolocalization GNSS Multi GNSS constellation chipset (GPS+GALILEO) BLE Sensolus proximity beacon detection Detectable by zone and high precision anchors Wi-Fi scanning Wi-Fi based geolocalization Wi-Fi 2.4 GHz Sensing Internal Activity monitoring Orientation monitoring Virtual tamper detection Temperature monitoring range: -20°C till 60°C (-4°F to 140°F) typical accuracy: +/- 0.25°C (+/- 0.45°F) worst case accuracy: +/- 1°C (+/- 1.8°F) Configurable shock detection Environmental BLE sensors Temperature, humidity Fill level, contact, magnet Other BLE sensors can be added Mounting Holes 6x8 mm. 90 mm distance between the centers of the mounting holes. Mechanics & Design Antennas All antennas are internal Water & dust resistance IP68 Size 105x54x21.5 mm (LWH) Weight 95 gram Color White Operating temperature -20°C to 60°C\* The specifics regarding operational temperature are contingent upon the application, installation circumstances, and environmental factors such as sunlight exposure. For further information, please reach out to Sensolus. Battery life can be affected when devices function for extended periods at the extremes of this range. Casing Polycarbonate (lexan943A) Flame retardant UV-stabilized Size 130x72x36 mm\\n(5⅛ x 2⁵³⁄₆₄ x 1²⁷⁄₆₄ in) Weight 212 gram (7.6 oz) Water & dust resistance IP68 & IP69K Impact resistance IK09 Operating temperature -20°C to 60°C\\n(-4°F to 140°F)\* Color White Casing Shell: PBT + PC Cover: PBT GF30% + TPE Flame retardant UV-stabilized Battery 3 to 8 years battery life depending on operating mode Replaceable battery pack 4600 mAh 3.0 V(Li-MnO₂) Battery weight: 30 gram (1.06 oz) 1.58 gram (0.0557 oz) lithium Certifications Regulatory In progress Bluetooth 5.0 In progress Electrical safety In progress User Interaction Device activation Magnetic activation LED feedback Green & red LED feedback on the device Synchronize remote settings Instant: Magnet activation Periodic: No user interaction needed Management Services Diagnostics Battery lifetime prediction Detailed energy consumption Geolocation diagnostics Installation Communication quality Management OTA firmware updates over NB-IoT,LTE-M and BLE Remote configuration Tracker usage profiles External environmental sensors Application services Localization Journeys Activity Utilization Connectable with environmental sensors Temperature detection Tilt detection Shock detection Firmware configuration Communication service Data recovery strategy Communication conditions Location service Motion based,context based, periodic or scheduled Configurable update rate and journey detection Priority sequence (GNSS, Wi-Fi scanning , Bluetooth geobeacon) GNSS fix parameters Quuppa certified for high precision Indoor detection algo Wi-Fi scan strategy BLE scan strategy General configuration Rule engine configuration Diagnostic levels Boot methods Accurate time synchronization Orientation service Orientation detection parameters Environmental sensing Polling and aggregation strategy Alerts Edge processing parameters Activity service Activity detection parameters Tamper service Virtual tamper algo configuration Shock detection Shock algo detection parameters Security Device unique encryption keys End to end payload encryption Chacha 20 AES encrypted firmware Firmware upgrade allows only signed firmware images Management & Security User Interaction Magnetic activation Green & red LED feedback Instant/periodic settings sync Management Services OTA firmware updates Remote configuration Battery lifetime prediction Geolocation diagnostics Security Device unique encryption keys End-to-end ChaCha20 encryption AES encrypted firmware Signed firmware images only \*The specifics regarding operational temperature are contingent upon the application, installation circumstances, and environmental factors such as sunlight exposure. Battery life can be affected when devices function for extended periods at the extremes of this range. Installation and activation manual TRACK 1115 and TRACK 1115 WL: Mounting the tracker Guidelines how to mount the tracker can be found here. Tracker activation Activation of the trackers is preferably done with clear skies, and not inside (e.g. factory or warehouse). Trackers are not activated when delivered to your premises. Their subscription in the platform will start within six months of purchase. Activation troubleshooting Activating a tracker that communicates over the NB-IoT or LTE-M network can sometimes come with a delay. With a delay we mean that the online status doesn\'t appear within 5 minutes after holding the magnet to the tracker. This is mostly due to conditions on the network operator site. If the activation wasn\'t successful after 5 minutes the tracker will try again to activate again after waiting 24 hours. This long period of time is often an obstacle to start installing trackers to assets and makes the timing of the installation of the trackers cumbersome as it is important to only install trackers when they appeared as online on the platform. To overcome to 24 hours waiting time, you can do the following: If after 5 minutes of waiting and the status didn\'t change yet to "online" hold the magnet again for 5 seconds on top of the tracker to enforce a new attempt for activation. Keep trying every 5 minutes until the Online status appears. Installation advice Troubleshooting 1. Put the magnet on the tracker for less than 5 seconds 2. The possible LED feedback options are: Force new configuration download on the tracker Regulatory Information Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user\'s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This equipment is not suitable for use in locations where children are likely to be present. Industry Canada Statement This device complies with ISED\'s licence-exempt RSSs. Operation is subject to the following two conditions: This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be chosen so that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. RF Exposure Requirements: This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Le présent appareil est conforme aux CNR d\' ISED applicables aux appareils radio exempts de licence. L\'exploitation est autorisée aux deux conditions suivantes: 1. le dispositif ne doit pas produire de brouillage préjudiciable, et 2. ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. Conformément à la réglementation d\'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d\'un type et d\'un gain maximal (ou inférieur) approuvé pour l\'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radio électrique à l\'intention des autres utilisateurs, il faut choisir le type d\'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l\'intensité nécessaire à l\'établissement d\'une communication satisfaisante. Déclaration d\'exposition aux radiations: Cet équipement est conforme aux limites d\'exposition aux rayonnements du Canada établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal ./images/Activation\_track\_1115\_step\_1.png Hold magnet on tracker Hold a magnet for about 5 seconds on top of the logo on the asset tracker. ./images/Activation\_track\_1115\_step\_2.png Red LED indicator You will first see a red LED. Do not remove the magnet yet. ./images/Activation\_track\_1115\_step\_3.png Green LED blinking When the green LED is blinking you can remove the magnet. Your tracker is ready for use. Avoid metal blocking Avoid blocking the tracker\'s view with metal or carbonfibre walls. They weaken or block the radiofrequency signals. Mount high Place the tracker as high as possible on the asset to ensure good network coverage. Clean surface Make sure the mounting surface is flat and clean, for a strong and durable bond. Avoid shocks Do not install the tracker on parts that receive frequent shocks or vibrations. Vertical mounting Install the tracker vertically, with the logo facing up. Protected location If your asset is handled in a rough environment, you can place the tracker in a protected location, but never with metal or carbonfibre above the tracker. Clear view Make sure the tracker has a clear view on the sky. Avoid water Avoid placing the tracker in a place that can collect water. Not upside down If you can\'t install vertically, do not mount the tracker upside down. Do not install on dashboard Do not install the tracker on the car dashboard. Red LED Red LED: Tracker is not activated Green LED Green LED: Tracker is activated and working properly No LED No LED: tracker is not functioning (probably dead battery -> contact support) Red LED blinking Red LED is blinking: Tracker is busy ./images/Force\_new\_config\_download\_TRACK\_1115\_step\_1.png Hold magnet Hold a magnet for about 5 seconds on top of the logo on the asset tracker. You will see a green LED. ./images/Force\_new\_config\_dowload\_TRACK\_1115\_step\_2.png Red and green LED You will see a red and green LED. Now remove the magnet. ./images/Force\_new\_config\_download\_TRACK\_1115\_step\_3.png Green LED blinking Green LED is blinking for minimum 30 seconds. Your tracker is checking for new configurations. ./images/Force\_new\_config\_download\_TRACK\_1115\_step\_4A.png Red LED - No new config You see a red LED: No new configuration received. ./images/Force\_new\_config\_download\_TRACK\_1115\_step\_4B.png Green LED - New config You see a green LED: New configuration setting received. Installation and activation manual TRACK 1115 and TRACK 1115 WL # TRACK 1115 WL Source: https://doc.sensolus.com/docs/spec_sheets/trackers/track_1115_wl TRACK 1115 WL ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/trackers/images/TRACK_1115_WL.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=31b15d713c7a0ff567916109013ea452) For installation instructions, see [Installation instructions](/docs/spec_sheets/installation_instructions). TRACK 1115 WL: Installation All mounting options for this device can be found in the Sensolus product mounting instructions. TRACK 1115 WL GNSS/Wi-Fi/BLE - NB-IoT/LTE-M The small low-power tracker with long battery life. Indoor and outdoor localization, zone and high precision. Compatible with multiple external environmental sensors. GNSS Wi-Fi scanning Bluetooth geobeacon for zone precision NB-IoT LTE-M Europe and North America Data recovery IP68 Flame retardant TRACK 1115 WL 76×54×21.5 mm 90g (3.2 oz) Connectivity NB-IoT and LTE-M Energy efficient transceiver Internal omnidirectional antenna Bi-directional communication NB-IoT and LTE-M bands: Europe/North America Data recovery OTA firmware upgrade (NB-IoT or LTE-M) Connectivity plan TRACK 1115 WL comes with the Extended connectivity plan Bluetooth Low Energy (BLE) Bluetooth Low Energy 5.0 Geolocalization GNSS Multi GNSS constellation chipset (GPS+GALILEO) BLE Sensolus proximity beacon detection Detectable by zone and high precision anchors Wi-Fi scanning Wi-Fi based geolocalization Wi-Fi 2.4 GHz Sensing Internal Activity monitoring Orientation monitoring Virtual tamper detection Temperature monitoring range: -20°C till 60°C (-4°F to 140°F) typical accuracy: +/- 0.25°C (+/- 0.45°F) worst case accuracy: +/- 1°C (+/- 1.8°F) Configurable shock detection Environmental BLE sensors Temperature, humidity Fill level, contact, magnet Other BLE sensors can be added Mechanics & Design Antennas All antennas are internal Water & dust resistance IP68 Size 76x54x21.5 mm (LWH) Weight 90 gram Color White Operating temperature -20°C to 60°C\* The specifics regarding operational temperature are contingent upon the application, installation circumstances, and environmental factors such as sunlight exposure. For further information, please reach out to Sensolus. Battery life can be affected when devices function for extended periods at the extremes of this range. Casing Polycarbonate (lexan943A) Flame retardant UV-stabilized Size 130x72x36 mm\\n(5⅛ x 2⁵³⁄₆₄ x 1²⁷⁄₆₄ in) Weight 212 gram (7.6 oz) Water & dust resistance IP68 & IP69K Impact resistance IK09 Operating temperature -20°C to 60°C\\n(-4°F to 140°F)\* Color White Casing Shell: PBT + PC Cover: PBT GF30% + TPE Flame retardant UV-stabilized Battery 3 to 8 years battery life depending on operating mode Replaceable battery pack 4600 mAh 3.0 V(Li-MnO₂) Battery weight: 30 gram (1.06 oz) 1.58 gram (0.0557 oz) lithium Certifications Regulatory In progress Bluetooth 5.0 In progress Electrical safety In progress User Interaction Device activation Magnetic activation LED feedback Green & red LED feedback on the device Synchronize remote settings Instant: Magnet activation Periodic: No user interaction needed Management Services Diagnostics Battery lifetime prediction Detailed energy consumption Geolocation diagnostics Installation Communication quality Management OTA firmware updates over NB-IoT,LTE-M and BLE Remote configuration Tracker usage profiles External environmental sensors Application services Localization Journeys Activity Utilization Connectable with environmental sensors Temperature detection Tilt detection Shock detection Firmware configuration Communication service Data recovery strategy Communication conditions Location service Motion based,context based, periodic or scheduled Configurable update rate and journey detection Priority sequence (GNSS, Wi-Fi scanning , Bluetooth geobeacon) GNSS fix parameters Quuppa certified for high precision Indoor detection algo Wi-Fi scan strategy BLE scan strategy General configuration Rule engine configuration Diagnostic levels Boot methods Accurate time synchronization Orientation service Orientation detection parameters Environmental sensing Polling and aggregation strategy Alerts Edge processing parameters Activity service Activity detection parameters Tamper service Virtual tamper algo configuration Shock detection Shock algo detection parameters Security Device unique encryption keys End to end payload encryption Chacha 20 AES encrypted firmware Firmware upgrade allows only signed firmware images Management & Security User Interaction Magnetic activation Green & red LED feedback Instant/periodic settings sync Management Services OTA firmware updates Remote configuration Battery lifetime prediction Geolocation diagnostics Security Device unique encryption keys End-to-end ChaCha20 encryption AES encrypted firmware Signed firmware images only \*The specifics regarding operational temperature are contingent upon the application, installation circumstances, and environmental factors such as sunlight exposure. Battery life can be affected when devices function for extended periods at the extremes of this range. Installation and activation manual TRACK 1115 and TRACK 1115 WL: Mounting the tracker Guidelines how to mount the tracker can be found here. Tracker activation Activation of the trackers is preferably done with clear skies, and not inside (e.g. factory or warehouse). Trackers are not activated when delivered to your premises. Their subscription in the platform will start within six months of purchase. Activation troubleshooting Activating a tracker that communicates over the NB-IoT or LTE-M network can sometimes come with a delay. With a delay we mean that the online status doesn\'t appear within 5 minutes after holding the magnet to the tracker. This is mostly due to conditions on the network operator site. If the activation wasn\'t successful after 5 minutes the tracker will try again to activate again after waiting 24 hours. This long period of time is often an obstacle to start installing trackers to assets and makes the timing of the installation of the trackers cumbersome as it is important to only install trackers when they appeared as online on the platform. To overcome to 24 hours waiting time, you can do the following: If after 5 minutes of waiting and the status didn\'t change yet to "online" hold the magnet again for 5 seconds on top of the tracker to enforce a new attempt for activation. Keep trying every 5 minutes until the Online status appears. Installation advice Troubleshooting 1. Put the magnet on the tracker for less than 5 seconds 2. The possible LED feedback options are: Force new configuration download on the tracker Regulatory Information Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user\'s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This equipment is not suitable for use in locations where children are likely to be present. Industry Canada Statement This device complies with ISED\'s licence-exempt RSSs. Operation is subject to the following two conditions: This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be chosen so that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. RF Exposure Requirements: This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Le présent appareil est conforme aux CNR d\' ISED applicables aux appareils radio exempts de licence. L\'exploitation est autorisée aux deux conditions suivantes: 1. le dispositif ne doit pas produire de brouillage préjudiciable, et 2. ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. Conformément à la réglementation d\'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d\'un type et d\'un gain maximal (ou inférieur) approuvé pour l\'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radio électrique à l\'intention des autres utilisateurs, il faut choisir le type d\'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l\'intensité nécessaire à l\'établissement d\'une communication satisfaisante. Déclaration d\'exposition aux radiations: Cet équipement est conforme aux limites d\'exposition aux rayonnements du Canada établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal ./images/Activation\_track\_1115\_step\_1.png Hold magnet on tracker Hold a magnet for about 5 seconds on top of the logo on the asset tracker. ./images/Activation\_track\_1115\_step\_2.png Red LED indicator You will first see a red LED. Do not remove the magnet yet. ./images/Activation\_track\_1115\_step\_3.png Green LED blinking When the green LED is blinking you can remove the magnet. Your tracker is ready for use. Avoid metal blocking Avoid blocking the tracker\'s view with metal or carbonfibre walls. They weaken or block the radiofrequency signals. Mount high Place the tracker as high as possible on the asset to ensure good network coverage. Clean surface Make sure the mounting surface is flat and clean, for a strong and durable bond. Avoid shocks Do not install the tracker on parts that receive frequent shocks or vibrations. Vertical mounting Install the tracker vertically, with the logo facing up. Protected location If your asset is handled in a rough environment, you can place the tracker in a protected location, but never with metal or carbonfibre above the tracker. Clear view Make sure the tracker has a clear view on the sky. Avoid water Avoid placing the tracker in a place that can collect water. Not upside down If you can\'t install vertically, do not mount the tracker upside down. Do not install on dashboard Do not install the tracker on the car dashboard. Red LED Red LED: Tracker is not activated Green LED Green LED: Tracker is activated and working properly No LED No LED: tracker is not functioning (probably dead battery -> contact support) Red LED blinking Red LED is blinking: Tracker is busy ./images/Force\_new\_config\_download\_TRACK\_1115\_step\_1.png Hold magnet Hold a magnet for about 5 seconds on top of the logo on the asset tracker. You will see a green LED. ./images/Force\_new\_config\_dowload\_TRACK\_1115\_step\_2.png Red and green LED You will see a red and green LED. Now remove the magnet. ./images/Force\_new\_config\_download\_TRACK\_1115\_step\_3.png Green LED blinking Green LED is blinking for minimum 30 seconds. Your tracker is checking for new configurations. ./images/Force\_new\_config\_download\_TRACK\_1115\_step\_4A.png Red LED - No new config You see a red LED: No new configuration received. ./images/Force\_new\_config\_download\_TRACK\_1115\_step\_4B.png Green LED - New config You see a green LED: New configuration setting received. Installation and activation manual TRACK 1115 and TRACK 1115 WL # TRACK 1130 Source: https://doc.sensolus.com/docs/spec_sheets/trackers/track_1130 TRACK 1130 Battery powered tracker that uses Wi-Fi sniffing for localization ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/trackers/images/TRACK-1130.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=27d0ee79b1de5229b557e473f8da0e8b) For installation instructions, see [Installation instructions](/docs/spec_sheets/installation_instructions). TRACK 1130 spec sheet: November 12, 2025 11:03 AM [www.sensolus.com](http://www.sensolus.com) | [info@sensolus.com](mailto:info@sensolus.com) LYKANER N5 - WIFI - NB-IoT TRACK 1130 Connectivity Geolocalization 50mm (1 ³¹/₃₂ in) 31,5 mm (1 ¹⁵/₆₄ in) 140 mm (5 ³³/₆₄ in) The long-life battery powered WIFI tracker communicating over the NB-IoT network. Wi-Fi Wi-Fi based geolocalization Sensing Internal · Relocation based on acceleration · Orientation state ∅5,2mm ∅5,2mm (¹³/₆₄ in) 125,35 mm (4 ¹⁵/₁₆ in) · Energy efficient transceiver · Internal omnidirectional antenna · Bi-directional communication NB-IoT IP69 Mechanics & design Water & dust resistance Size 140 x50x31,5 mm (5 ³³/₆₄ x 1 ³¹/₃₂ x 1 ¹⁵/₆₄ in) (L W H) Weight 146 gram (5.15 oz) Color Black Casing PC/PBT -20°C to 60°C (-4°F to 140°F) Operating temperature Antennas All antennas are internal IK8 Impact resistance · NB-IoT bands: Europe and North America · Data recovery · OTA firmware upgrade (NB-IoT) Wi-Fi IP69 IK8 NB-IoT Europe and North America Data recovery Up to 7 years of battery life (read the details) · TRACK 1130 comes with the Standard connectivity plan. Connectivity plan November 12, 2025 11:03 AM [www.sensolus.com](http://www.sensolus.com) | [info@sensolus.com](mailto:info@sensolus.com) Certifications Regulatory CE, UK-CA, FCC, IC, CGF, PTCRB User interaction Device activation Activation with button (push hard for at least 5 sec.) LED feedback LED will blink for 10 sec to confirm the activation. Battery · Not replaceable battery pack: Li-SoCl2,2xER17505M-L 3,6V 5600mAh Management services · Remote configuration · Tracker usage profiles · Low battery alert · 4 battery levels · Communication quality Diagnostics Management Application services · Localization · Geozones Firmware configuration Location service Periodic and relocation parameters Communication service Data recovery configuration (optional) General configuration · Boot methods · Time synchronization Tamper service Virtual tamper algo configuration Security · Device unique encryption keys · End to end payload encryption Chacha 20 · AES encrypted firmware · Firmware upgrade allows only signed firmware images Mounting · Activation manual · Instructions for mounting the device are available in the Sensolus documentation center. TRACK 1130 drill hole template: 125,35 mm Drilling hole pattern for TRACK 1130 Do not scale this drawing! Print on A4 paper Installation and activation manual TRACK 1130: Tracker activation Trackers are not activated when delivered to your premises, to avoid battery consumption before actual deployment. The tracker is a one-time activation device: once it is activated, it cannot be deactivated afterward. The activation status can be verified by looking up the device in the Sensolus portal using the device serial number. To effectively start using the tracker, it must be activated using the following method: Activation of the tracker is preferably done in a place where there are Wi-Fi networks, which makes it easier to confirm that a first Wi-Fi location resolution has succeeded after activation. The platform subscription costs for the tracker start when it is first activated, or latest after six months after the shipment date. In the (exceptional) case that activation sequence cannot be completed within 3 minutes (for example in areas lacking coverage by the communication provider), the device will employ a temporary back-off strategy to avoid draining the battery (2 x 30 minutes, 12 hours and then 24 hours). This means that feedback responsiveness may be reduced when encountering this problem. Mounting the tracker on the asset Guidelines how to mount the tracker can be found here. Recommended device orientation For optimal battery usage please follow the below device mounting orientation recommendations: Recommended Acceptable Not recommended Installation advice Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal ./images/Activation\_track\_1130\_step\_1.png Press activation button Press the activation button and keep it pressed for at least 5 seconds. You can hear or feel a click when the button is effectively pressed. You can also use the blunt back of a pen or pencil for this. ./images/Activation\_track\_1130\_step\_2.png Red LED blinking The red LED will blink for 10 seconds to confirm that it is starting the activation sequence. ./images/Activation\_track\_1130\_step\_3.png LED blinking completion Once activation sequence is completed, the device will for a second time emit LED blinking for 5 seconds to indicate the completion of the activation sequence. ./images/Activation\_track\_1130\_step\_4.png After activation After activation and during normal operation, the LED does not light up. center 20px 0 flex center 40px flex-start center bold 10px center bold 10px center bold 10px Avoid metal blocking Avoid blocking the tracker\'s view with metal or carbonfibre walls. They weaken or block the radiofrequency signals. Mount high Place the tracker as high as possible on the asset to ensure good network coverage. Clean surface Make sure the mounting surface is flat and clean, for a strong and durable bond. Avoid shocks Do not install the tracker on parts that receive frequent shocks or vibrations. Avoid water Avoid placing the tracker in a place that can collect water. Protected location If your asset is handled in a rough environment, you can place the tracker in a protected location, but never with metal or carbonfibre above the tracker. Installation and activation manual TRACK 1130 Recommended orientation Acceptable orientation Not recommended orientation # TRACK 1141 Source: https://doc.sensolus.com/docs/spec_sheets/trackers/track_1141 TRACK 1141 Battery powered GPS tracker for outdoor asset localization ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/trackers/images/TRACK-1141.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=ee0c5faddfd59eb479cdf491b9a31f68) For installation instructions, see [Installation instructions](/docs/spec_sheets/installation_instructions). TRACK 1141: TRACK 1141 GNSS/BLE - NB-IoT The rugged low-power tracker with long battery life with NB-IoT connectivity and guaranteed data recovery. The tracker provides general localization, zone and high precision. The tracker firmware can be upgraded over the air. GNSS Bluetooth geobeacon for zone precision NB-IoT Europe and North America Data recovery IP69K & IP68 IK 09 Flame retardant TRACK 1141 130×72×36 mm 212g (7.6 oz) Connectivity NB-IoT Energy efficient transceiver Internal omnidirectional antenna Bi-directional communication NB-IoT bands: Europe/North America Data recovery OTA firmware upgrade (NB-IoT) Bluetooth Low Energy (BLE) Bluetooth Low Energy 5.0 Geolocalization GNSS Multi GNSS constellation chipset (GPS+GALILEO) BLE Sensolus proximity beacon detection Detectable by zone and high precision anchors Sensing Internal Activity monitoring Orientation monitoring Virtual tamper detection Activation and mounting Activation manual link Holes 7x9mm for screws or rivets. 115 mm distance between the centers of the mounting holes. Instructions for mounting the device can be found here. Mechanics & Design Antennas All antennas are internal Water & dust resistance IP68 & IP69K Size 130x72x36 mm(LWH)) Impact resistance IK09 Weight 212 gram (7.6 oz) Drop shock and vibration EN 60068 Color White Operating temperature -20°C to 60°C\* The specifics regarding operational temperature are contingent upon the application, installation circumstances, and environmental factors such as sunlight exposure. For further information, please reach out to Sensolus. Battery life can be affected when devices function for extended periods at the extremes of this range. Casing Shell: PBT + PC Cover: PBT GF30% + TPE Flame retardant UV-stabilized Size 130x72x36 mm\\n(5⅛ x 2⁵³⁄₆₄ x 1²⁷⁄₆₄ in) Weight 212 gram (7.6 oz) Water & dust resistance IP68 & IP69K Impact resistance IK09 Operating temperature -20°C to 60°C\\n(-4°F to 140°F)\* Color White Casing Shell: PBT + PC Cover: PBT GF30% + TPE Flame retardant UV-stabilized Battery Standard 3 cell User replaceable battery pack (Li-SoCl₂) 10500 mAh 2.94 gram lithium Certifications Regulatory CE FCC Bluetooth 5.0 Declaration ID D068598 Electrical safety EN 62368-1 User Interaction Device activation Magnetic activation LED feedback Green & red LED feedback on the device Synchronize remote settings Instant: Magnet activation Periodic: No user interaction needed Management Services Diagnostics Battery lifetime prediction Detailed energy consumption Geolocation diagnostics Installation Communication quality Management OTA firmware updates over NB-IoT and BLE Remote configuration Tracker usage profiles Application services Localization Journeys Activity Utilization Firmware configuration Communication service Data recovery strategy Communication conditions Location service Motion based, periodic or scheduled Configurable update rate and journey detection Priority sequence (GNSS, Bluetooth geobeacon) GNSS fix parameters Indoor detection algo BLE scan strategy General configuration Rule engine configuration Diagnostic levels Boot methods Accurate time synchronization Orientation service Orientation detection parameters Activity service Activity detection parameters Tamper service Virtual tamper algo configuration Security Device unique encryption keys End to end payload encryption Chacha 20 AES encrypted firmware Firmware upgrade allows only signed firmware images Management & Security User Interaction Magnetic activation Green & red LED feedback Instant/periodic settings sync Management Services OTA firmware updates Remote configuration Battery lifetime prediction Geolocation diagnostics Security Device unique encryption keys End-to-end ChaCha20 encryption AES encrypted firmware Signed firmware images only \*The specifics regarding operational temperature are contingent upon the application, installation circumstances, and environmental factors such as sunlight exposure. Battery life can be affected when devices function for extended periods at the extremes of this range. Installation and activation manual TRACK 1101 and TRACK 1141: Mounting the tracker Guidelines how to mount the tracker can be found here. Tracker activation Activation of the trackers is preferably done with clear skies, and not inside (e.g. factory or warehouse). Trackers are not activated when delivered to your premises. Their subscription in the platform will start within six months of purchase. Activation troubleshooting Activating a tracker that communicates over the NB-IoT or LTE-M network can sometimes come with a delay. With a delay we mean that the online status doesn\'t appear within 5 minutes after holding the magnet to the tracker. This is mostly due to conditions on the network operator site. If the activation wasn\'t successful after 5 minutes the tracker will try again to activate again after waiting 24 hours. This long period of time is often an obstacle to start installing trackers to assets and makes the timing of the installation of the trackers cumbersome as it is important to only install trackers when they appeared as online on the platform. To overcome to 24 hours waiting time, you can do the following: If after 5 minutes of waiting and the status didn\'t change yet to "online" hold the magnet again for 5 seconds on top of the tracker to enforce a new attempt for activation. Keep trying every 5 minutes until the Online status appears. Installation advice Troubleshooting 1. Put the magnet on the tracker for less than 5 seconds 2. The possible LED feedback options are: Force new configuration download on the tracker Regulatory Information Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user\'s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This equipment is not suitable for use in locations where children are likely to be present. Industry Canada Statement This device complies with ISED\'s licence-exempt RSSs. Operation is subject to the following two conditions: This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be chosen so that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. RF Exposure Requirements: This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Le présent appareil est conforme aux CNR d\' ISED applicables aux appareils radio exempts de licence. L\'exploitation est autorisée aux deux conditions suivantes: 1. le dispositif ne doit pas produire de brouillage préjudiciable, et 2. ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. Conformément à la réglementation d\'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d\'un type et d\'un gain maximal (ou inférieur) approuvé pour l\'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radio électrique à l\'intention des autres utilisateurs, il faut choisir le type d\'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l\'intensité nécessaire à l\'établissement d\'une communication satisfaisante. Déclaration d\'exposition aux radiations: Cet équipement est conforme aux limites d\'exposition aux rayonnements du Canada établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal ./images/Activation\_track\_1101\_step\_1.png Hold magnet on tracker Hold a magnet for about 5 seconds on top of the logo on the asset tracker. ./images/Activation\_track\_1101\_step\_2.png Red LED indicator You will first see a red LED. Do not remove the magnet yet. ./images/Activation\_track\_1101\_step\_3.png Green LED blinking When the green LED is blinking you can remove the magnet. Your tracker is ready for use. Avoid metal blocking Avoid blocking the tracker\'s view with metal or carbonfibre walls. They weaken or block the radiofrequency signals. Mount high Place the tracker as high as possible on the asset to ensure good network coverage. Clean surface Make sure the mounting surface is flat and clean, for a strong and durable bond. Avoid shocks Do not install the tracker on parts that receive frequent shocks or vibrations. Vertical mounting Install the tracker vertically, with the logo facing up. Protected location If your asset is handled in a rough environment, you can place the tracker in a protected location, but never with metal or carbonfibre above the tracker. Clear view Make sure the tracker has a clear view on the sky. Avoid water Avoid placing the tracker in a place that can collect water. Not upside down If you can\'t install vertically, do not mount the tracker upside down. Thermal insulation Place thermal insulation material, such as wood or plastic, between the tracker and the metal asset if the asset produces heat — for example, engines. Red LED Red LED: Tracker is not activated Green LED Green LED: Tracker is activated and working properly No LED No LED: tracker is not functioning (probably dead battery -> contact support) Red LED blinking Red LED is blinking: Tracker is busy ./images/FORCE\_NEW\_CONFIG\_STEP\_1.png Hold magnet Hold a magnet for about 5 seconds on top of the logo on the asset tracker. You will see a green LED. ./images/FORCE\_NEW\_CONFIG\_STEP\_2.png Red and green LED You will see a red and green LED. Now remove the magnet. ./images/FORCE\_NEW\_CONFIG\_STEP\_3.png Green LED blinking Green LED is blinking for minimum 30 seconds. Your tracker is checking for new configurations. ./images/FORCE\_NEW\_CONFIG\_STEP\_4.png Red LED - No new config You see a red LED: No new configuration received. ./images/FORCE\_NEW\_CONFIG\_STEP\_5.png Green LED - New config You see a green LED: New configuration setting received. Installation and activation manual TRACK 1101 and TRACK 1141 Sensolus drill hole template: 115 mm Drilling hole patterns for TRACK 1000 1001 1040 1100 Do not scale this drawing! Print on A4 paper # TRACK 1160 Source: https://doc.sensolus.com/docs/spec_sheets/trackers/track_1160 TRACK 1160 ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/trackers/images/TRACK-1160.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=e5967ba518192a82c03dc0396b628b78) For installation instructions, see [Installation instructions](/docs/spec_sheets/installation_instructions). TRACK 1160: TRACK 1160 GNSS/Wi-Fi/BLE - LTE Cat 1bis The rugged low-power tracker with long battery life with LTE Cat 1bis connectivity and guaranteed data recovery. The tracker provides general localization, zone and high precision. The tracker comes with an onboard temperature sensor and shock detection. Compatible with multiple external environmental sensors. The tracker firmware can be upgraded over the air. GNSS Wi-Fi scanning Bluetooth geobeacon for zone precision Quuppa tested for high precision LTE Cat 1bis Depending on communication contract. Data recovery IP69K & IP68 IK 09 Flame retardant TRACK 1160 130×72×36 mm 212g (7.6 oz) Connectivity LTE Cat 1bis Energy efficient transceiver Internal omnidirectional antenna Bi-directional communication LTE Cat 1bis bands: Depending on communication contract. Data recovery OTA firmware upgrade (LTE Cat 1bis) Connectivity plan TRACK 1160 comes with the Extended connectivity plan Bluetooth Low Energy (BLE) Bluetooth Low Energy 5.0 Geolocalization GNSS Multi GNSS constellation chipset (GPS+GALILEO) BLE Sensolus proximity beacon detection Detectable by zone and high precision anchors Wi-Fi scanning Wi-Fi based geolocalization Wi-Fi 2.4 GHz Sensing Internal Activity monitoring Orientation monitoring Virtual tamper detection Temperature monitoring range: -20°C till 60°C (-4°F to 140°F) typical accuracy: +/- 0.25°C (+/- 0.45°F) worst case accuracy: +/- 1°C (+/- 1.8°F) Configurable shock detection Environmental BLE sensors Temperature, humidity Fill level, contact, magnet Other BLE sensors can be added Activation and mounting Activation and mounting Activation manual Holes 7x9mm (⁹/₃₂ \* ²³/₆₄ in) for screws or rivets. 115 mm (4¹⁷/₃₂ in) distance between the centers of the mounting holes. Instructions for mounting the device are available in the Sensolus documentation center. Mechanics & Design Antennas All antennas are internal Water & dust resistance IP68 & IP69K Size 130x72x36 mm\\n(5⅛ x 2⁵³⁄₆₄ x 1²⁷⁄₆₄ in) Impact resistance IK09 Weight 212 gram (7.6 oz) Drop shock and vibration EN 60068 Color White Operating temperature -20°C to 60°C\\n(-4°F to 140°F)\* The specifics regarding operational temperature are contingent upon the application, installation circumstances, and environmental factors such as sunlight exposure. For further information, please reach out to Sensolus. Battery life can be affected when devices function for extended periods at the extremes of this range. Casing Shell: PBT + PC Cover: PBT GF30% + TPE Flame retardant UV-stabilized Size 130x72x36 mm\\n(5⅛ x 2⁵³⁄₆₄ x 1²⁷⁄₆₄ in) Weight 212 gram (7.6 oz) Water & dust resistance IP68 & IP69K Impact resistance IK09 Operating temperature -20°C to 60°C\\n(-4°F to 140°F)\* Color White Casing Shell: PBT + PC Cover: PBT GF30% + TPE Flame retardant UV-stabilized Battery Standard 3 cell User replaceable battery pack (Li-SoCl₂) 10800 mAh 2.94 gram (0.1037oz) lithium Certifications Regulatory CE FCC IC Bluetooth 5.0 Declaration ID D068598 Environmental Drop shock in progress Electrical safety EN 62368-1 User Interaction Device activation Magnetic activation LED feedback Green & red LED feedback on the device Synchronize remote settings Instant: Magnet activation Periodic: No user interaction needed Management Services Diagnostics Battery lifetime prediction Detailed energy consumption Geolocation diagnostics Installation Communication quality Management OTA firmware updates over LTE Cat 1bis and BLE Remote configuration Tracker usage profiles External environmental sensors Application services Localization Journeys Activity Utilization Connectable with environmental sensors Temperature detection Tilt detection Shock detection Firmware configuration Communication service Data recovery strategy Communication conditions Location service Motion based,context based, periodic or scheduled Configurable update rate and journey detection Priority sequence (GNSS, Wi-Fi scanning , Bluetooth geobeacon) GNSS fix parameters Quuppa certified for high precision Indoor detection algo Wi-Fi scan strategy BLE scan strategy General configuration Rule engine configuration Diagnostic levels Boot methods Accurate time synchronization Orientation service Orientation detection parameters Environmental sensing Polling and aggregation strategy Alerts Edge processing parameters Activity service Activity detection parameters Tamper service Virtual tamper algo configuration Shock detection Shock algo detection parameters Security Device unique encryption keys End to end payload encryption Chacha 20 AES encrypted firmware Firmware upgrade allows only signed firmware images Management & Security User Interaction Magnetic activation Green & red LED feedback Instant/periodic settings sync Management Services OTA firmware updates Remote configuration Battery lifetime prediction Geolocation diagnostics Security Device unique encryption keys End-to-end ChaCha20 encryption AES encrypted firmware Signed firmware images only \*The specifics regarding operational temperature are contingent upon the application, installation circumstances, and environmental factors such as sunlight exposure. Battery life can be affected when devices function for extended periods at the extremes of this range. Installation and activation manual TRACK 1160: Mounting the tracker Guidelines how to mount the tracker can be found here. Tracker activation Activation of the trackers is preferably done with clear skies, and not inside (e.g. factory or warehouse). Trackers are not activated when delivered to your premises. Their subscription in the platform will start within six months of purchase. Activation troubleshooting Activating a tracker that communicates over the NB-IoT or LTE-M network can sometimes come with a delay. With a delay we mean that the online status doesn\'t appear within 5 minutes after holding the magnet to the tracker. This is mostly due to conditions on the network operator site. If the activation wasn\'t successful after 5 minutes the tracker will try again to activate again after waiting 24 hours. This long period of time is often an obstacle to start installing trackers to assets and makes the timing of the installation of the trackers cumbersome as it is important to only install trackers when they appeared as online on the platform. To overcome to 24 hours waiting time, you can do the following: If after 5 minutes of waiting and the status didn\'t change yet to "online" hold the magnet again for 5 seconds on top of the tracker to enforce a new attempt for activation. Keep trying every 5 minutes until the Online status appears. Installation advice Troubleshooting 1. Put the magnet on the tracker for less than 5 seconds 2. The possible LED feedback options are: Force new configuration download on the tracker Regulatory Information Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user\'s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This equipment is not suitable for use in locations where children are likely to be present. Industry Canada Statement This device complies with ISED\'s licence-exempt RSSs. Operation is subject to the following two conditions: This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be chosen so that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. RF Exposure Requirements: This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Le présent appareil est conforme aux CNR d\' ISED applicables aux appareils radio exempts de licence. L\'exploitation est autorisée aux deux conditions suivantes: 1. le dispositif ne doit pas produire de brouillage préjudiciable, et 2. ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. Conformément à la réglementation d\'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d\'un type et d\'un gain maximal (ou inférieur) approuvé pour l\'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radio électrique à l\'intention des autres utilisateurs, il faut choisir le type d\'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l\'intensité nécessaire à l\'établissement d\'une communication satisfaisante. Déclaration d\'exposition aux radiations: Cet équipement est conforme aux limites d\'exposition aux rayonnements du Canada établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. public ./images/Activation\_track\_1101\_step\_1.png Hold magnet on tracker Hold a magnet for about 5 seconds on top of the logo on the asset tracker. ./images/Activation\_track\_1101\_step\_2.png Red LED indicator You will first see a red LED. Do not remove the magnet yet. ./images/Activation\_track\_1101\_step\_3.png Green LED blinking When the green LED is blinking you can remove the magnet. Your tracker is ready for use. Avoid metal blocking Avoid blocking the tracker\'s view with metal or carbonfibre walls. They weaken or block the radiofrequency signals. Mount high Place the tracker as high as possible on the asset to ensure good network coverage. Clean surface Make sure the mounting surface is flat and clean, for a strong and durable bond. Avoid shocks Do not install the tracker on parts that receive frequent shocks or vibrations. Vertical mounting Install the tracker vertically, with the logo facing up. Protected location If your asset is handled in a rough environment, you can place the tracker in a protected location, but never with metal or carbonfibre above the tracker. Clear view Make sure the tracker has a clear view on the sky. Avoid water Avoid placing the tracker in a place that can collect water. Not upside down If you can\'t install vertically, do not mount the tracker upside down. Thermal insulation Place thermal insulation material, such as wood or plastic, between the tracker and the metal asset if the asset produces heat — for example, engines. Red LED Red LED: Tracker is not activated Green LED Green LED: Tracker is activated and working properly No LED No LED: tracker is not functioning (probably dead battery -> contact support) Red LED blinking Red LED is blinking: Tracker is busy ./images/FORCE\_NEW\_CONFIG\_STEP\_1.png Hold magnet Hold a magnet for about 5 seconds on top of the logo on the asset tracker. You will see a green LED. ./images/FORCE\_NEW\_CONFIG\_STEP\_2.png Red and green LED You will see a red and green LED. Now remove the magnet. ./images/FORCE\_NEW\_CONFIG\_STEP\_3.png Green LED blinking Green LED is blinking for minimum 30 seconds. Your tracker is checking for new configurations. ./images/FORCE\_NEW\_CONFIG\_STEP\_4.png Red LED - No new config You see a red LED: No new configuration received. ./images/FORCE\_NEW\_CONFIG\_STEP\_5.png Green LED - New config You see a green LED: New configuration setting received. Installation and activation manual TRACK 1160 # TRACK 1203 Source: https://doc.sensolus.com/docs/spec_sheets/trackers/track_1203 TRACK 1203 Externally powered vehicle tracker ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/docs/spec_sheets/trackers/images/TRACK-1203.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=cb45c62e4811abe63d590b00d0e7bd77) For installation instructions, see [Installation instructions](/docs/spec_sheets/installation_instructions). TRACK 1203 spec sheet EN: December 12, 2024 10:20 AM [www.sensolus.com](http://www.sensolus.com) | [info@sensolus.com](mailto:info@sensolus.com) Waterproof 4G LTE Cat 1 tracker with flexible inputs TRACK 1203 GNSS 67 mm IP67 External power source Internal back up battery Track 1203 wired is a smart and waterproof GNSS tracker with internal backup battery. Mounting · Tie wraps · Double sided tape Geolocalization GNSS GPS, GLONASS, GALILEO, BEIDOU, QZSS, AGPS Connectivity Mobile network 4G (SIM-card is required) with fallback to 3G (UMTS), 2G (GSM) networks 25.6 mm 110 mm December 12, 2024 10:20 AM [www.sensolus.com](http://www.sensolus.com) | [info@sensolus.com](mailto:info@sensolus.com) Power · Input voltage: 10 - 30 V DC with overvoltage protection · Back up battery : 170 mAh Li-Ion, 3.7 V battery (0.63 Wh) Certifications Regulatory CE-RED, E-Mark,RCM,Anatel, REACH, RoHS, TRA, CITC Configuration Configuration and firmware update · FOTA · Remote device configuration Time synchronisation · GNSS · NITZ · NTP Application services · Localization · Journeys · Activity · Utilization · Speed · Travelled distance Mechanics & design Size Weight 110 mm x 67 mm x 25,6 mm 80 gram (without power cable) Color · Internal High Gain GNSS antenna · Internal GSM High Gain Celullar antenna Antenna IP67 Water & dust resistance casing -20 to 85°C Operating temperature -20 to 85°C (without battery) Storage temperature Light Gray Sensors Accelerometer Memory 128MB internal flash memory 5% to 95% non-condensing Operating humidity Power cable · 2 fork connectors for battery connection · 90 cm TRACK 1203 installation manual: Advice before installation 1. Orientation of the tracker Install with connection plug in line of the driving direction. Do not install perpendicular to the driving direction. 2. Do not install upside down 3. Avoid placement of TRACK 1203 under metal surfaces 4. Mount horizontal TRACK 1203 must be placed so its state is as horizontal as possible. If TRACK 1203 is leant more than 30 degrees, it is considered incorrect mounting. Mounting the device 1. Connect the plug 2. Attach to plus and minus pole of the vehicle battery Connect the wires to the vehicle battery: - Red = plus pole (positive terminal) - Black = minus pole (negative terminal) 3. Attach to a surface with printed side facing up Install the tracker with the TOP side facing up. You can use double-sided tape or tie wraps to secure the device. Install with double-sided tape or tie wraps Install with TOP side facing up Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal Correct orientation, plug faces driving direction Install with connection plug in line of the driving direction. Wrong orientation - do not install perpendicular to driving direction Do not install perpendicular to the driving direction. 20px 0 400px 20px 0 400px 20px 0 400px 20px 0 600px 20px 0 600px flex 20px 20px 0 wrap 1 250px 350px 10px 1 250px 350px 10px TRACK 1203 installation manual Do not install upside down Avoid metal surfaces above tracker Mount horizontal - correct and incorrect positions Connect the plug to the device Battery connection diagram Install with double-sided tape or tie wraps Install with TOP side facing up # TRACK 1215 Source: https://doc.sensolus.com/docs/spec_sheets/trackers/track_1215 TRACK 1215 Battery powered vehicle tracker with optional external power supply connection ![](https://mintcdn.com/sensolus/MM6I8yrrDr30P0_Y/global-images/hardware_pictures/TRACK_1215.png?fit=max\&auto=format\&n=MM6I8yrrDr30P0_Y\&q=85\&s=1538b1591f608cf93f94f2ab8a0d067b) For installation instructions, see [Installation instructions](/docs/spec_sheets/installation_instructions). ## TRACK 1215 cable wiring ### External power source - cable wiring The cable provided with TRACK 1215 has a length of 2 meters. The cable allows connecting the tracker to a power source of a vehicle (car / truck / trailer battery). A cable of 6 meters can be purchased separately. The optional power source must be within the range of **10V to 30V, direct current (DC)** . Be aware that you need to supply your own connectors (U-shaped or circular clamps) and solder them to the wires (reason: different vehicles batteries have different sizes of connectors). Protect the soldering using heat shrink. The external cable is composed of 4 internal wires: * **Black** : GND / Ground. Connect to black battery terminal (negative, minus sign). * **Red** : VIN External voltage in. Connect to red battery terminal (positive, plus sign). * **Blue** : Digital In / Analog In (not in use currently; pending a future firmware release). * **White** : Digital Out. (not in use currently; pending a future firmware release). TRACK 1215: TRACK 1215 GNSS/Wi-Fi/BLE - NB-IoT/LTE-M Deploy this tracker connected to the vehicle power source, or only use the internal backup battery to avoid the wiring effort. It has NB-IoT and LTE-M connectivity and guaranteed data recovery. Provides outdoor and indoor localization. Supports external BLE sensors. Acts as smart BLE gateway to locate BLE-tagged assets transported by the vehicle. GNSS Wi-Fi scanning Bluetooth geobeacon for zone precision NB-IoT LTE-M Connectivity EXTENDED plan Data recovery Large internal backup battery IP67 IK 09 Flame retardant TRACK 1215 130×72×36 mm 212g (7.6 oz) Connectivity NB-IoT and LTE-M Energy efficient transceiver Internal omnidirectional antenna Bi-directional communication Data recovery OTA firmware upgrade (NB-IoT and LTE-M) Bluetooth Low Energy (BLE) Bluetooth Low Energy 5.0 Connectivity plan TRACK 1215 comes with the Extended connectivity plan Geolocalization GNSS Multi GNSS constellation chipset (GPS+GALILEO) BLE Geobeacon Sensolus geobeacon detection Wi-Fi scanning Wi-Fi based geolocalization Sensing Internal Activity monitoring Orientation monitoring Virtual tamper detection Temperature monitoring range: -20°C till 60°C (-4°F to 140°F) typical accuracy: +/- 0.25°C (+/- 0.45°F) worst case accuracy: +/- 1°C (+/- 1.8°F) Configurable shock detection Accessory BLE sensors Temperature, humidity Fill level, contact, magnet Other BLE sensors can be added Activation and mounting Activation manual Holes 7x9mm (⁹/₃₂ \* ²³/₆₄ in) for screws or rivets. 115 mm (4¹⁷/₃₂ in) distance between the centers of the mounting holes. Instructions for mounting the device can be found here. Mechanics & Design Antennas All antennas are internal Water & dust resistance IP67 Size 130x72x36 mm\\n(5⅛ x 2⁵³⁄₆₄ x 1²⁷⁄₆₄ in) Impact resistance IK09 Weight 218 gram (7.68 oz) without cable Drop shock and vibration EN 60068 Color White and black Operating temperature -20°C to 60°C\\n(-4°F to 140°F)\* Casing PBT/PC 29 TM-Z2 FR UV LS Flame retardant UV-stabilized Size 130x72x36 mm\\n(5⅛ x 2⁵³⁄₆₄ x 1²⁷⁄₆₄ in) Weight 212 gram (7.6 oz) Water & dust resistance IP68 & IP69K Impact resistance IK09 Operating temperature -20°C to 60°C\\n(-4°F to 140°F)\* Color White Casing Shell: PBT + PC Cover: PBT GF30% + TPE Flame retardant UV-stabilized Power supply Voltage Input voltage: 10 - 30 V DC with overvoltage protection Typical power consumption \~3mA (idle) Cable terminations Connectors to the power source can be soldered to the cable ends Max typical power consumption 300mA (@10V) 70mA (@30V) Fuse recommendations > 500mA and \< 1A fuse The TRACK 1215 contains a non-resettable 1A slow blow fuse (Bel fuse 0685T1000) at its external power input. Back up battery Standard 3 cell Battery life depending on operating mode. User replaceable battery pack (Li-SoCl₂) 12000 mAh 2.94 gram (0.1037oz) lithium Certifications Regulatory CE FCC IC Bluetooth 5.0 Declaration ID D068598 Environmental Drop shock Electrical safety EN 62368-1 User Interaction Device activation Magnetic activation LED feedback Green & red LED feedback on the device Synchronize remote settings Instant: Magnet activation Periodic: No user interaction needed Management Services Diagnostics Battery lifetime prediction Detailed energy consumption Geolocation diagnostics Installation Communication quality Management OTA firmware updates over NB-IoT,LTE-M and BLE Remote configuration Tracker usage profiles External environmental sensors Application services Localization Journeys Activity Utilization Connectable with environmental sensors Temperature detection Tilt detection Shock detection Firmware configuration Communication service Data recovery strategy Communication conditions Location service Motion based,context based, periodic or scheduled Configurable update rate and journey detection Priority sequence (GNSS, Wi-Fi scanning , Bluetooth geobeacon) GNSS fix parameters Indoor detection algo Wi-Fi scan strategy BLE scan strategy General configuration Rule engine configuration Diagnostic levels Boot methods Accurate time synchronization Orientation service Orientation detection parameters Environmental sensing Polling and aggregation strategy Alerts Edge processing parameters Activity service Activity detection parameters Tamper service Virtual tamper algo configuration Shock detection Shock algo detection parameters Security Device unique encryption keys End to end payload encryption Chacha 20 AES encrypted firmware Firmware upgrade allows only signed firmware images Accessories CAB 8600: 6 m power cable for TRACK 1215 Management & Security User Interaction Magnetic activation Green & red LED feedback Instant/periodic settings sync Management Services OTA firmware updates Remote configuration Battery lifetime prediction Geolocation diagnostics Security Device unique encryption keys End-to-end ChaCha20 encryption AES encrypted firmware Signed firmware images only \*The specifics regarding operational temperature are contingent upon the application, installation circumstances, and environmental factors such as sunlight exposure. Battery life can be affected when devices function for extended periods at the extremes of this range. Installation manual TRACK 1215 for BLE tag scanning in vehicles: Tracker activation Activation of the tracker is preferably done with clear skies, and not inside (e.g. factory or warehouse). Trackers are not activated when delivered to your premises. Their subscription in the platform will start within six months of purchase. Activation troubleshooting Activating a tracker that communicates over the NB-IoT network can sometimes come with a delay. With a delay we mean that the online status doesn\'t appear within 5 minutes after holding the magnet to the tracker. This is mostly due to conditions on the network operator site. If the activation wasn\'t successful after 5 minutes the tracker will try again to activate again after waiting 24 hours. This long period of time is often an obstacle to start installing trackers to assets and makes the timing of the installation of the trackers cumbersome as it is important to only install trackers when they appeared as online on the platform. To overcome the 24 hours waiting time, you can do the following: If after 5 minutes of waiting and the status didn\'t change yet to "online" hold the magnet again for 5 seconds on top of the tracker to enforce a new attempt for activation. Keep trying every 5 minutes until the Online status appears. General installation advice Preparing the installation in the vehicle Tools and equipment Before the actual wiring 1. The tracker should be mounted in the middle of the truck or van. 2. Detect the best possible path from the vehicle\'s power source to the place of tracker installation. Estimate the amount of wire needed to cover the complete path. 3. Make sure the 2 wire cable can pass everywhere, use the steel fish tape to test. Installing the tracker Wiring the truck 1. Route the cable : Use the steel fish tape to pull the wire through the available shafts of the truck. Preferably work from the ground up. This might take a while, take your time. Make sure not to damage the cable. 2. Prepare the cable length : Make sure there is enough 2 wired cable to go to the vehicle\'s power source. Do not connect anything to the power source yet. 3. Protect the cable : Protect the 2 cable wire where needed: - Use cable duct and double sided tape for the inside of the van or truck. - Use cable protector for the outside of the van or truck. 4. Install the fuse : An additional fuse ( 500mA and \< 1A) can be installed. Install the fuse on the voltage in red cable in series. The tracker has an internal fuse, see specsheet for details. The external cable is composed of 4 internal wires: - Black : GND / Ground. Connect to black battery terminal (negative, minus sign). - Red : VIN External voltage in. Connect to red battery terminal (positive, plus sign). - Blue : Digital In / Analog In (not in use currently; pending a future firmware release). - White : Digital Out (not in use currently; pending a future firmware release). 5. Install connectors on the vehicle wiring : Install the female spade connectors on the installed wires on the inside of the truck. 6. Install connectors near the power source : Install the fork connectors to the end of the 2 wired cable near the power source. Do not attach to the battery yet. 7. Install connectors on the tracker cable : Install the male spade connectors on the tracker cable. Mounting the tracker Guidelines how to mount the tracker can be found here. Mount the tracker in such a way that you have good access and a good view to the power plug of the tracker. Power the tracker Attach the fork connectors to the vehicle\'s battery. The tracker is now powered. Force new configuration download on the tracker A firmware can be uploaded on the tracker. Queue the firmware in the Sensolus platform first. Troubleshooting 1. Put the magnet on the tracker for less than 5 seconds 2. The possible LED feedback options are: Regulatory Information Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user\'s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This equipment is not suitable for use in locations where children are likely to be present. Industry Canada Statement This device complies with ISED\'s licence-exempt RSSs. Operation is subject to the following two conditions: This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be chosen so that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. RF Exposure Requirements: This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Le présent appareil est conforme aux CNR d\' ISED applicables aux appareils radio exempts de licence. L\'exploitation est autorisée aux deux conditions suivantes: 1. le dispositif ne doit pas produire de brouillage préjudiciable, et 2. ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. Conformément à la réglementation d\'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d\'un type et d\'un gain maximal (ou inférieur) approuvé pour l\'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radio électrique à l\'intention des autres utilisateurs, il faut choisir le type d\'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l\'intensité nécessaire à l\'établissement d\'une communication satisfaisante. Déclaration d\'exposition aux radiations: Cet équipement est conforme aux limites d\'exposition aux rayonnements du Canada établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal ./images/Activation\_track\_1210\_step\_1.svg Hold magnet on tracker Hold a magnet for about 5 seconds on top of the logo on the tracker. ./images/Activation\_track\_1210\_step\_2.svg Red LED indicator You will first see a red LED. Do not remove the magnet yet. ./images/Activation\_track\_1210\_step\_3.svg Green LED blinking When the green LED is blinking you can remove the magnet. The tracker is ready for use. Protected location If your asset is handled in a rough environment, you can place the tracker in a protected location, but never with metal or carbonfibre above the tracker. Mount high Place the tracker as high as possible on the asset to ensure good network coverage. Clean surface Make sure the mounting surface is flat and clean, for a strong and durable bond. Avoid shocks Do not install the tracker on parts that receive frequent shocks or vibrations. Avoid water Avoid placing the tracker in a place that can collect water. 2 wire cable Enough 2 wire cable Steel fish tape Steel fish tape Cable duct Cable duct Spade connectors Male and female spade connectors Fork connectors Fork connectors Cable protector Cable protector Wire cutter Wire cutter Screwdriver Screwdriver Double sided tape Double sided tape Wrench set Wrench set Stanley knife Stanley knife Electrical fuse Electrical fuse (> 500mA and \< 1A) 100% 20px 0 Cable duct inside the van or truck Cable duct inside the van or truck Cable protector outside the truck Cable protector outside the truck 300px 20px 0 Wrong mounting - no view on plug Wrong: No view on tracker plug Correct mounting - view on plug Correct: Good view on tracker plug ./images/Attach\_connector\_track\_1210\_step\_1.svg Put cable onto connector Put the cable onto the connector. Only the black plastic piece will go into the connector. Do not force this. ./images/Attach\_connector\_track\_1210\_step\_2.svg Tighten the connection Tighten the connection by gently screwing the cable into the connector. Do not force this. ./images/Attach\_connector\_track\_1210\_step\_3.svg Check connection Check if the power cable is connected well. ./images/Force\_config\_track\_1210\_step\_1.svg Hold magnet Hold a magnet for about 5 seconds on top of the logo on the asset tracker. You will see a green LED. ./images/Force\_config\_track\_1210\_step\_2.svg Red and green LED You will see a red and green LED. Now remove the magnet. ./images/Force\_config\_track\_1210\_step\_3.svg Green LED blinking Green LED is blinking for minimum 30 seconds. Your tracker is checking for new configurations. ./images/Force\_config\_track\_1210\_step\_4A.svg Red LED - No new config You see a red LED: No new configuration received. ./images/Force\_config\_track\_1210\_step\_4B.svg Green LED - New config You see a green LED: New configuration setting received. Red LED Red LED: Tracker is not activated Green LED Green LED: Tracker is activated and working properly No LED No LED: Tracker is not functioning (probably dead battery -> contact support) Red LED blinking Red LED is blinking: Tracker is busy Installation manual TRACK 1215 for BLE tag scanning in vehicles Tracker placement in middle of truck Fuse wiring diagram Installation manual TRACK 1215: Tracker activation Activation of the tracker is preferably done with clear skies, and not inside (e.g. factory or warehouse). Trackers are not activated when delivered to your premises. Their subscription in the platform will start within six months of purchase. Activation troubleshooting Activating a tracker that communicates over the NB-IoT network can sometimes come with a delay. With a delay we mean that the online status doesn\'t appear within 5 minutes after holding the magnet to the tracker. This is mostly due to conditions on the network operator side. If the activation wasn\'t successful after 5 minutes the tracker will try to activate again after waiting 24 hours. This long period of time is often an obstacle to start installing trackers to assets and makes the timing of the installation of the trackers cumbersome as it is important to only install trackers when they appeared as online on the platform. To overcome the 24 hours waiting time, you can do the following: If after 5 minutes the status still hasn\'t changed to "online", hold the magnet again for 5 seconds on top of the tracker to force a new activation attempt. Keep trying every 5 minutes until the online status appears. General installation advice Tools and equipment Mount the tracker onto the vehicle Guidelines how to mount the tracker can be found here. Mount the tracker in such a way you have good access and a good view to the power plug of the tracker. The tracker cable The tracker has an internal fuse (see the spec sheet for details). An additional external fuse ( 500mA and \< 1A) can be installed in series on the red wire — this is done during wiring, see the steps below. The external cable is composed of 4 internal wires: - Black : GND / Ground. Connect to black battery terminal (negative, minus sign). - Red : VIN External voltage in. Connect to red battery terminal (positive, plus sign). - Blue : Digital In / Analog In (not in use currently; pending a future firmware release). - White : Digital Out (not in use currently; pending a future firmware release). Connect tracker to the vehicle power source Wiring to a battery Locate the battery of the trailer or truck and find the ground and power cable. See if you can cut them: - If you can cut them, you do not need the fork connectors. Follow Option A . - If you cannot cut them, you need to use the fork connectors. Follow Option B . Option A: Cut the power and ground wires What do you need? - Enough 2-wire cable - Wire stripper - Heat shrink tubing - Heat shrink tubing cable lugs - Tie wraps - Multi-crimp tool - Heat gun - Electrical fuse ( 500mA and \< 1A) 1. Find the power and ground cable that come from the battery and cut them. 2. Strip the cut cable ends for at least 1 cm. 3. Install the fuse ( 500mA and \< 1A) in series on the red (power) wire. 4. Add the ground cable (black) of the tracker to the ground cable of the battery and add the power cable (red) to the power cable of the battery. 5. Put around 5 cm of heat shrink tubing over the cables. 6. Reconnect the cut cables with heat shrink tubing cable lugs using the multi-crimp tool. 7. Seal everything closely by heating the shrink tubes with a heat gun. Option B: Use fork connectors What do you need? - Enough 2-wire cable - Fork connectors - Wire stripper - Heat shrink tubing - Heat shrink tubing cable lugs - Tie wraps - Multi-crimp tool - Electrical fuse ( 500mA and \< 1A) - Heat gun Choose a good place to mount the tracker and measure the length of the wire you need. The TRACK 1215 comes standard with a 2 meter long cable. 1. Find the power and ground terminal on the battery and check if the fork connectors fit the terminals. 2. Strip the 2-wire cable at both ends for at least 1 cm. 3. Attach the fork connectors to one end of the 2-wire cable — one connector for ground, one for power. Seal securely with heat shrink tubing using the heat gun. Do not fix the fork connectors on the battery yet. 4. Install the fuse ( 500mA and \< 1A) in series on the red (power) wire. 5. Take the heat shrink tubing cable lugs. Put the other side of the cable and the wires of the connector cable to the tracker in them. Use the multi-crimp tool to tighten. Cover the connection with heat shrink tubing and seal them with the heat gun. 6. Plug in the connector to the mounted tracker. 7. Make sure the wires are in place using the tie wraps. 8. Connect the fork connectors to the battery. Wiring to trailer lights In this example the tracker will only be powered by the external power source when it is switched on. In all other cases the tracker will use its backup battery. What do you need? - Wire stripper - Heat shrink tubing - Heat shrink tubing cable lugs - Tie wraps - Multi-crimp tool - Heat gun - Electrical fuse ( 500mA and \< 1A) 1. Find the power and ground cable of the trailer lights of the truck and cut them. 2. Strip the cut cable ends for at least 1 cm. 3. Install the fuse ( 500mA and \< 1A) in series on the red (power) wire. 4. Add the ground cable (black) of the tracker to the ground cable of the trailer lights and add the power cable (red) to the power cable of the trailer lights. 5. Put around 5 cm of heat shrink tubing over the cables. 6. Reconnect the cut cables with heat shrink tubing cable lugs using the multi-crimp tool. 7. Seal everything closely by heating the shrink tubes with a heat gun. Force new configuration download on the tracker A new configuration can be downloaded to the tracker. Queue the configuration in the Sensolus platform first. Troubleshooting 1. Put the magnet on the tracker for less than 5 seconds 2. The possible LED feedback options are: Regulatory Information Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user\'s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This equipment is not suitable for use in locations where children are likely to be present. Industry Canada Statement This device complies with ISED\'s licence-exempt RSSs. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be chosen so that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. RF Exposure Requirements: This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Le présent appareil est conforme aux CNR d\' ISED applicables aux appareils radio exempts de licence. L\'exploitation est autorisée aux deux conditions suivantes: 1. le dispositif ne doit pas produire de brouillage préjudiciable, et 2. ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. Conformément à la réglementation d\'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d\'un type et d\'un gain maximal (ou inférieur) approuvé pour l\'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radio électrique à l\'intention des autres utilisateurs, il faut choisir le type d\'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l\'intensité nécessaire à l\'établissement d\'une communication satisfaisante. Déclaration d\'exposition aux radiations: Cet équipement est conforme aux limites d\'exposition aux rayonnements du Canada établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Safety advice – device subjected to strong mechanical impact Risk of delayed battery failure and chemical hazard If a device has been hit, crushed, or struck by a heavy object (for example a forklift, container, pallet, or falling load), the internal components and battery may be damaged even if no external damage is visible. Such damage can result in delayed overheating, leakage, or failure. If a device has been subjected to a strong mechanical impact, the following mandatory safety actions must be taken: Action Details :-- :------- :-------- 1 Do not touch the device Do not move, lift, open, shake, or inspect the device immediately after the impact. Internal damage may cause delayed reactions. 2 Keep a minimum safety distance Maintain a clear distance of at least 5 meters from the device. Keep all personnel away during this period. 3 Wait at least 10 minutes The device must remain untouched and undisturbed for a minimum of 10 minutes following the impact. This waiting time allows potential delayed thermal or chemical reactions to become evident. 4 Observe from a safe distance Watch for warning signs: smoke, vapor, or unusual odor; heat generation; fluid leakage; hissing, cracking, or popping noises. 5 After the waiting period If any abnormal condition is observed, isolate the area immediately and notify responsible safety or supervisory personnel. The device must be quarantined and handled according to battery safety and disposal procedures. The device must not be used. A device may appear undamaged and still be unsafe. Normal operation after impact does NOT mean the device is safe. Failure to follow this safety advice may result in serious injury, fire, or chemical exposure. sensolus-internal ./images/Activation\_track\_1210\_step\_1.svg Hold magnet on tracker Hold a magnet for about 5 seconds on top of the logo on the tracker. ./images/Activation\_track\_1210\_step\_2.svg Red LED indicator You will first see a red LED. Do not remove the magnet yet. ./images/Activation\_track\_1210\_step\_3.svg Green LED blinking When the green LED is blinking you can remove the magnet. The tracker is ready for use. Protected location If your asset is handled in a rough environment, you can place the tracker in a protected location, but never with metal or carbon fibre above the tracker. Mount high Place the tracker as high as possible on the asset to ensure good network coverage. Clean surface Make sure the mounting surface is flat and clean, for a strong and durable bond. Avoid shocks Do not install the tracker on parts that receive frequent shocks or vibrations. Avoid water Avoid placing the tracker in a place that can collect water. 2 wire cable Enough 2-wire cable Fork connectors Fork connectors Wire stripper Wire stripper Heat shrink tubing Heat shrink tubing Heat shrink tubing cable lugs Heat shrink tubing cable lugs Tie wraps Tie wraps Multi-crimp tool Multi-crimp tool Electrical fuse Electrical fuse (> 500mA and \< 1A) Heat gun Heat gun flex 20px 20px 0 ./images/Attach\_connector\_track\_1210\_step\_1.svg Put cable onto connector Put the cable onto the connector. Only the black plastic piece will go into the connector. Do not force this. ./images/Attach\_connector\_track\_1210\_step\_2.svg Tighten the connection Tighten the connection by gently screwing the cable into the connector. Do not force this. ./images/Attach\_connector\_track\_1210\_step\_3.svg Check connection Check if the power cable is connected well. 300px 20px 0 ./images/Force\_config\_track\_1210\_step\_1.svg Hold magnet Hold a magnet for about 5 seconds on top of the logo on the asset tracker. You will see a green LED. ./images/Force\_config\_track\_1210\_step\_2.svg Red and green LED You will see a red and green LED. Now remove the magnet. ./images/Force\_config\_track\_1210\_step\_3.svg Green LED blinking Green LED is blinking for minimum 30 seconds. Your tracker is checking for new configurations. ./images/Force\_config\_track\_1210\_step\_4A.svg Red LED - No new config You see a red LED: No new configuration received. ./images/Force\_config\_track\_1210\_step\_4B.svg Green LED - New config You see a green LED: New configuration setting received. Red LED Red LED: Tracker is not activated Green LED Green LED: Tracker is activated and working properly No LED No LED: Tracker is not functioning (probably dead battery -> contact support) Red LED blinking Red LED is blinking: Tracker is busy Installation manual TRACK 1215 Correct mounting - view on plug Wrong mounting - no view on plug Fuse wiring diagram Sensolus drill hole template: 115 mm Drilling hole patterns for TRACK 1000 1001 1040 1100 Do not scale this drawing! Print on A4 paper CAB 8600: Documentation CAB 8600 6 m power extension cable The 6-meter power cable is designed for use with TRACK 1210 and TRACK 1215. It has 4 pins and is securely attached to the tracker with an M5 screw connector. The cable does not come with connectors for the power source: connectors can be soldered to the cable ends. External power supply IP67 when connected CAB 8600 6 m cable length Compatibility Connected devices TRACK 1210 TRACK 1215 Connector to tracker M5 screw General specification Cable length 6 m Connections 4 pins Cable terminations Connectors to the power source can be soldered to the cable ends IP rating IP67 when connected Temperature range -40°C - 85°C Electrical specifications Rated voltage 60V AC/DC Rated current 1A Contact resistance ≤5 mΩ Insulation resistance ≥100 MΩ Mating cycles > 100 Certifications RoHS Yes SDOC-498608282-1044 6 meter power extension cable for TRACK 1215 / TRACK 1210